I want to search for...

Permit #2007040148

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00490-0050
CONDITIONED SPACE: 1815 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 354 sqft
OPENED PORCH (WITH ROOF) : 63 sqft
Total Square Footage: 2628 sqft
Block: 00490
Subdivision: -
Job Phone: (386) 672-8285
Location Address: 12 WOOD CEDAR DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/24/2007
NOC: RECORDED
Applicant name: JOSEPH TODD VANACORE
Owner: DENNIS C ROSS FAMILY LIMITED PARTNERSHIP

Address

4560 NORTH HWY US 1

BUNNELL, FL 32110

Lot: 0050
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

VANACORE CONSTRUCTION INC.
Status Location Address Mailing Address State License Number Phone
INACTIVE

1451 N US HIGHWAY 1

Ormond Beach, FL 32174

SUITE 13

Ormond Beach, FL 32174

CBC058991 (Exp: 08/31/2024) (386) 672-8285

Sub Contractors

DANIEL R SHEFFIELD
Status Location Address State License Number Phone
INACTIVE

1100 Old Haw Creek Road

Bunnell, FL 32110

EC0003100 (Exp: 08/31/2024) 386-931-4729
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
NORMAN LEE HUGHES
Status Location Address State License Number Phone
CANCEL

6429 Fruit Ave

Bunnell, FL 32110

CFC057334 (Exp: 09/30/2008) (386) 437-2702
JOSEPH TODD VANACORE
Status Location Address Mailing Address State License Number Phone
INACTIVE

1451 N US HIGHWAY 1

Ormond Beach, FL 32174

SUITE 13

Ormond Beach, FL 32174

CBC058991 (Exp: 08/31/2024) (386) 672-8285

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 10/26/2007 FINAL APPROVED ACOOPER
FINAL COMPLETE BUILDING INSPECTION 10/25/2007 Disapproved -FEE REQUIRED JLEVRAULT
Note: THIS IS A REINSPECTION FILL HOLE WHERE AIR CONDITIONING LINES RUN FROM HOUSE TO CONDENSING UNIT. NO RATING ON PULL DOWN IN GARAGE.
FINAL COMPLETE BUILDING INSPECTION 10/24/2007 Disapproved -FEE REQUIRED MMOORE
Note: NEED AN ARC SHIELD ON MASTERBATH REC. NEED TO HAVE A SERVICE RECEPTACLE ON THE SAME LEVEL AS THE ATTIC AHU.
STORMWATER FINAL INSPECTION 10/22/2007 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION 44 sf road.$452
STORMWATER FINAL INSPECTION 10/18/2007 Disapproved -FEE REQUIRED DRANDALL
Note: place sod in left side swale as marked, seed & straw not allowed in city right of way.....44 sf road damage $452.00
UTILITY COMPANY FINAL 10/12/2007 APPROVED MBACON
Note: Gravity ok.
UTILITY COMPANY FINAL 10/11/2007 Disapproved -FEE REQUIRED MBACON
Note: 4" Cleanout must be on owners property.
DRIVEWAY 09/24/2007 APPROVED DRANDALL
RESIDENTIAL EARLY POWER 08/28/2007 APPROVED LHITES
LATH /BRICK FLASHING 07/13/2007 APPROVED PGALLMANN
INSULATION INSPECTION 07/11/2007 APPROVED PGALLMANN
ALL ROUGH 07/09/2007 APPROVED ACOOPER
ALL ROUGH 07/06/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: 1-1/2" WASTE ARM SERVING GUEST BATH LAVATORY IS BACK-PITCHED.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/26/2007 APPROVED - AS NOTED ACOOPER
Note: INSUFFICIENT BEARING ON TRUSS T05. NEED APPROVED REPAIR, ON THE CORNER OF THE LAUNDRY ROOM - STRAP TOP PLATE TO WALL 2X4 FOR CONTINUOUS LOAD PATH.
TEMPORARY POLE 06/11/2007 APPROVED LHITES
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/11/2007 Disapproved - NO FEE PGALLMANN
Note: THIS IS A REINSPECTION... MUST HAVE ROOF FLASHINGS INSTALLED FOR THIS INSPECTION (#354).
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/04/2007 Disapproved -FEE REQUIRED MMOORE
Note: 1. truss plan not stamped 2. fill downcells as needed 3. header strapping detail needed 4. grout under trusses with stoneless grout
LINTEL 05/24/2007 APPROVED PGALLMANN
FOUNDATION SURVEY APPROVED BY STORMWATER 05/21/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 05/15/2007 APPROVED PGALLMANN
FIRST ROUGH PLUMBING INSPECTION 05/14/2007 APPROVED ACOOPER

Review History

Department Status Date In Date Out
BLD COMPLETE 07/03/2007 07/05/2007
Note: Released By: FREODICA Revisons: Truss repair Released per LW.
BLD REJECT 06/27/2007 06/28/2007
Note: Rejected By: CCOTE Truss repairs must be signed and sealed by truss engineer.
BLD COMPLETE 06/06/2007 06/07/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Header Detail.
SW1 COMPLETE 04/23/2007 04/24/2007
Note: Released By: LAPTEKAR
BLD COMPLETE 04/23/2007 04/23/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 04/12/2007 04/16/2007
Note: Held By: JJOSEPH Please Indicate how the beam will be connected to the block.(Connectors used)
ZON COMPLETE 04/09/2007 04/12/2007
Note: Released By: JGONZALEZ

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤452.00 10/29/2007
EARLY POWER INSPECTION ¤40.00 10/29/2007
REINSPECTION FEE ¤40.00 10/29/2007
REINSPECTION FEE ¤40.00 10/29/2007
REINSPECTION FEE ¤40.00 10/29/2007
REINSPECTION FEE ¤40.00 10/29/2007
REINSPECTION FEE ¤40.00 10/29/2007
REVISION ¤40.00 10/29/2007
STORMWATER REINSPECTION FEE ¤35.00 10/29/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 04/24/2007
ADMIN FEE ¤20.00 04/24/2007
ARC HOUSE REVIEW ¤125.00 04/24/2007
BUILDING CODE ADMIN FUND ¤13.14 04/24/2007
ELECTRIC FEE ¤138.60 04/24/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 04/24/2007
STORM WATER PERMIT FEES ¤80.00 04/24/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 04/24/2007
MECHANICAL FEE ¤138.60 04/24/2007
PERMIT FEE ¤705.90 04/24/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 04/24/2007
PLAN CHECK FEE ¤72.40 04/24/2007
PLUMBING FEE ¤138.60 04/24/2007
RADON FEE ¤13.14 04/24/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,825.43