I want to search for...

Permit #2007040171

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00140-0640
CONDITIONED SPACE: 2270 sqft
GARAGE: 642 sqft
OPENED PORCH (WITH ROOF) : 292 sqft
OPENED PORCH (WITH ROOF) : 199 sqft
Total Square Footage: 3403 sqft
Block: 00140
Subdivision: -
Job Phone: (386)437-5782
Location Address: 1 FORT CAROLINE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/15/2007
NOC: RECORDED
Applicant name: SANDRA LEE FRENCH
Owner: PUGA, MANUEL F. & CONCEICAO A

Address

32 EASTLAND TERRACE

NEW BEDFORD, MA 02740

Lot: 0640
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SANDEX HOMES
Status Location Address State License Number Phone Fax
CANCEL

27 EGAN DR

PALM COAST, FL

CRC1327302 (Exp: 09/30/2008) (386)437-5782 (386)437-5782

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone Fax
INACTIVE

720 MILL CREEK ROAD

JACKSONVILLE, FL 32211

EC13002215 (Exp: 08/31/2022) (386)437-4936 (904)743-4427
JOHN PHILLIPS
Status Location Address State License Number Phone Fax
CANCEL

235 S.R. 207 #2-B

ST. AUGUSTINE, FL 32080

CMC048017 (Exp: 08/30/2008) (904)823-1223 (904)823-1424
BRUCE EDWARD HAWKESWORTH
Status Location Address State License Number Phone
CANCEL

671 Dara Circle

DELTONA, FL 32735

CFC053329 (Exp: 09/30/2008) (386) 228-2784
MILLARD K KELLER
Status Location Address State License Number Phone Fax
CANCEL

313 S. VOLUSIA AVENUE

DELAND, FL 32724

CCC1325778 (Exp: 08/31/2010) (386) 774-9961 (386)774-2388

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/20/2008 FINAL APPROVED DROCKWELL
STORMWATER FINAL INSPECTION 03/17/2008 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 03/11/2008 Disapproved -FEE REQUIRED DRANDALL
Note: rake out dirt piles on vacant lot across street from driveway on foster ln. seed & straw same area [all exposed earth, extra dirt from final grade]. who cut trenches in swale to catch basin ? not maintainable with mower
UTILITY COMPANY FINAL 02/27/2008 APPROVED TSCHWEERS
Note: Gravity ok.
RESIDENTIAL EARLY POWER 02/01/2008 APPROVED LHITES
PRE DRIVEWAY 12/28/2007 APPROVED DRANDALL
LATH /BRICK FLASHING 11/21/2007 APPROVED CMINI
INSULATION INSPECTION 11/09/2007 APPROVED JGIBSON
ALL ROUGH 11/06/2007 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION MISSING FIRE BLOCKING IN TRAY CEILING IN KITCHEN NOOK WHERE BACKING AGAINST MASTER BEDROOM. RESEAL EXHAUST VENT FOR BATHROOM AT ROOF DECK WHERE BROKEN. WILL CHECK AT INSULATION
ALL ROUGH 11/02/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: THIS IS A REINSPECTION MISSING SHIMS AND ADEQUATE PENETRATION FROM CIRCLE-HEAD WINDOW INTO BUCK MATERIAL. 1/4" PENETRATION NOTED AT TIME OF INSPECTION.
ALL ROUGH 10/31/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: TIGHTEN GROUND SCREWS IN METAL BOXES. MARK ALL WHITE CONDUCTORS BEING USED AS HOTS INCLUDING THE PANEL. NO PRESSURE ON WATER PIPE. WASTE ARM AT LAUNDRY ROOM IS BACK PITCHED. SOKE DETECTOR IN MASTER BEDROOM NEEDS TO BE A T HIGHEST ELEVATION MISSING RECEPTACLES AT RIGHT OF BACK DOOR AND 2FT OF WALL SPACE IN FOYER.(A FOYER THAT SIZE IS NOT A HALLWAY)NOT READY FOR COMPLETE INSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/19/2007 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/15/2007 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION 1) REPAIR REVISION CALLS FOR 2X6 SYP SCABBED ON BOTH SIDES OF TRUSS......2) ..OSB MANUFACTURES SPECS CALLS ON VERTICAL STATES THATEND JOINTS MUST LIE OVER SUPPORTS... 3) MISSING ENGINEERING ON TRUSS R-04 4.) NEED TO TIGHTEN ANCHOR BOLT NUTS AT REAR DOOR...5) NEED ANCHOR BOLTS UNDER MITERED GLASS WINDOW EXTERIOR WALL..... 6).. NEED TO HAVE CONTIUOUS LOAD PATH AT KNEE WALL THAT TRUSSES R-03 SIT ON...7). NEED TO HAVE APPROVED PLANS FOR INSPECTION.. CHARLIE.... 931-1251
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/24/2007 Disapproved -FEE REQUIRED CMINI
Note: 1. NEED TO HAVE ROOF VALLEY FLASHED AND DRIP EDGE ON... 2 MISSING INTERMEDATE BLOCKING ON LOAD BEARING WALLS.. 3. STRAPS NEED TAPCONS BEHIND RIGID INSULATION..4. NEED REVISION REPAIR ON CUT TRUSS GDR02.. 5. NEED TO BLOCK HOINTS OF OSB THAT IS LAID VERTICALLY THAT IS NOT SITTING ON SUPPRTS.. 6. TIGHTEN ANCHOR BOLT NUTS AGAINST WALLS AND THREADED RODS.. 7. MISSING ENGINEERING PIECES CIRCLED ON SHEETS.. 8. NEED CONTIUOUS LOAD PATH AT KNEE WALL OF FRONT PORCH THAT TRUSSES R03 SIT ON.. 9. MUST PROVIDE VIEW HOLES FOR FRONT BEAM TIE DOWNS,ALSO CANNOT HAVE BREAK JOINT ON BEAM THAT IS NOT SITTING ON COLUMN. CHARLIE... 931-1251
LINTEL 08/28/2007 APPROVED CMINI
FOUNDATION SURVEY APPROVED BY STORMWATER 07/23/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 06/27/2007 APPROVED RMARVEL
Note:
MONOLITHIC SLAB INSPECTION/SLAB 06/25/2007 Disapproved -FEE REQUIRED RMARVEL
Note: NO PLANS ON JOB SITE.
FIRST ROUGH PLUMBING INSPECTION 06/20/2007 APPROVED JMCGOWEN

Review History

Department Status Date In Date Out
BLD COMPLETE 09/26/2007 09/27/2007
Note: Released By: FREODICA Rev. - Truss repair- Truss GDRO2.
ZON COMPLETE 04/19/2007 04/19/2007
Note: Released By: JGONZALEZ
BLD COMPLETE 04/19/2007 04/20/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 COMPLETE 04/16/2007 04/16/2007
Note: Released By: LAPTEKAR Fixed site plans to show driveway 50' from intersection on all site plans.
ZON HOLD 04/10/2007 04/15/2007
Note: Held By: ECOYNE plans state 24 Egan Drive What kind of cooking device on lanai Only 1 range is allowed in single family homes
SW1 HOLD 04/13/2007
Note: Held By: LAPTEKAR Appears to be two different site plans in file...one with driveway straight and one with driveway curved slightly ..

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 03/20/2008
REINSPECTION FEE ¤40.00 03/20/2008
REINSPECTION FEE ¤40.00 03/20/2008
REINSPECTION FEE ¤40.00 03/20/2008
REINSPECTION FEE ¤40.00 03/20/2008
REINSPECTION FEE ¤40.00 03/20/2008
REVISION ¤40.00 03/20/2008
STORMWATER REINSPECTION FEE ¤35.00 03/20/2008
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 06/15/2007
ADMIN FEE ¤20.00 06/15/2007
BUILDING CODE ADMIN FUND ¤17.02 06/15/2007
ELECTRIC FEE ¤169.80 06/15/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/15/2007
STORM WATER PERMIT FEES ¤80.00 06/15/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 06/15/2007
MECHANICAL FEE ¤169.80 06/15/2007
PERMIT FEE ¤908.70 06/15/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 06/15/2007
PLAN CHECK FEE ¤93.20 06/15/2007
PLUMBING FEE ¤169.80 06/15/2007
RADON FEE ¤17.02 06/15/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,573.39