Permit Details

Status: COED

Parcel Id: 16-12-31-5815-00000-0010
Total Square Footage: 2800 sqft
Subdivision: -
Job Phone: (904)241-4477
Location Address: 800 BELLE TERRE PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 05/29/2007
NOC: Unknown
Applicant name: DARRELL GLEN SMITH
Owner: NAP TOWN CENTER LLC

Address

7500 COLLEGE PARKWAY

FORT MYERS, FL 33907

Contracted Stated Job Value: ¤50,000.00
Job Description: BLDG. A UNIT 214 /216- -TENANT BUILDOUT FOR "BAMBOO CREEK ASIAN BISTRO"
Type: CN

Contractor

STYLES CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 50067

JACKSONVILLE BEACH, FL 32250

CBC1250669 (Exp: 08/31/2022) (904)241-4477 (904)241-0817

Sub Contractors

LARRY SANCHEZ
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 16007

JACKSONVILLE, FL 32245

CMC056273 (Exp: 08/31/2012) (904)564-1001 (904)564-9009
DARRELL GLEN SMITH
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 50067

JACKSONVILLE BEACH, FL 32240

CFC041803 (Exp: 08/31/2012) (904)241-4131 904-220-4309
MICHAEL L RUSS SR
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 730

DUNNELLON, FL 34430

CCC015610 (Exp: 08/31/2022) (352)489-4274 (352)489-3466
DAVID DEAN KEHR
Status Location Address State License Number Phone Fax
CANCEL

16445 VILLAGE GREEN DRIVE NORTH

JACKSONVILLE , FL 32220

ER0013906 (Exp: 08/31/2010) (904)778-2100 (904)781-1255
TOM FLOYD FITE
Status Location Address State License Number Phone Fax
CANCEL

922 SOUTH 9TH STREET

JACKSONVILLE, FL 32250

00838 (Exp: 08/31/2011) (904)246-7316 (904)249-0719
MICHAEL G O'KEEFE
Status Location Address State License Number Phone Fax
CANCEL

1716 HARPER STREET

JACKSONVILLE, FL 32204

CMC1249565 (Exp: 08/31/2012) 904-354-1378 (904)354-3669

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/07/2007 FINAL APPROVED JLEVRAULT
Note: ok to approve per Joe L
FIRE FINAL 11/06/2007 APPROVED JPATTEE
GAS FINAL 10/17/2007 APPROVED JLEVRAULT
UTILITY COMMERCIAL FINAL 10/17/2007 APPROVED KKING
UTILITY COMPANY FINAL 10/17/2007 APPROVED JHARDING
COMMERCIAL POWER INSPECTION 09/19/2007 APPROVED LHITES
ABOVE CEILING 09/18/2007 APPROVED JLEVRAULT
GAS ROUGH 07/18/2007 APPROVED JLEVRAULT
Note: Requested by Terri
SECOND ROUGH PLUMBING INSPECTION 06/19/2007 APPROVED - AS NOTED JGIBSON
Note: NEED REVISIONS ON WATER PIPING TO CPVC INSTEAD OF COPPER,MISSING INSULATION ON HOT SIDE ,CHANGING WATER HEATER TYPE,AND MIXING VALVES @ ALL LAVS, REMOVE GAS CHASE.
ALL ROUGH 06/15/2007 Disapproved - NO FEE JLEVRAULT
Note: NOT READY.
FRAMING 06/15/2007 APPROVED JLEVRAULT
Note:
H.V.A.C. ROUGH 06/15/2007 APPROVED JLEVRAULT
Note:
2ND ROUGH ELECTRICAL 06/15/2007 APPROVED LHITES
Note: walls and sheetrocked soffit only
MONOLITHIC SLAB INSPECTION/SLAB 06/04/2007 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 06/01/2007 APPROVED JGIBSON

Review History

Department Status Date In Date Out
FI1 COMPLETE 05/24/2007 05/25/2007
Note: Released By: BMEYERS Approved.
BLD COMPLETE 05/24/2007 05/25/2007
Note: Released By: CCOTE Approved for Release.
BLD HOLD 05/09/2007 05/16/2007
Note: Held By: JMONTARULI Released By: JMONTARULI Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2007040212 (800 Belle Terre - 214/216) 5/16/07 The following items must be resolved in order to complete the Building Permit plan review. 1. The Men's Restroom does not meet code requirements per the following: a. The single user stall is required to provide a stall 60 inches deep per Florida Plumbing Code Section 405.3.1. b. The single user stall door requires 21 inches clearance in front of the water closet to a door. If the stall is to remain with a side entrance door it would have to swing out. c. The entrance door to the Restroom infringes on the 21 inch clearance required in front of the lavatory per Florida Plumbing Code Section 405.3.1. 2. The Women's Restroom does not meet code requirements per the following: a. The handicap stall does not meet the Florida Specific accessible stall requirements. The lavatory infringes on the clear floor space required for the water closet which is not allowed. Refer to Figure 30e of the Florida Building Code. b. The stall door to the accessible stall infringes on the 21 inch clearance required in front of the lavatory per Florida Plumbing Code Section 405.3.1. *Revise all drawings as required to comply with the above items. ------------------------------------------------------------ Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------------------
BLD HOLD 04/24/2007 04/24/2007
Note: Held By: JMONTARULI Released By: JMONTARULI Held By: LWOODROME PLAN REVIEW COMMENTS: " Provide at least the minimum number of H.C. accessible seating positions per the Florida Building Code, section 11-5.1 (i.e. 5% of 73 = 3.65 = 4). " H.C. accessible seating must be distributed through out the establishment or space. " H.C. accessible toilet stalls must comply with FBC, section 11-4.17 and figure 30e. " Where a single urinal is provided, that urinal must be H.C. accessible and no door shall swing into the required clear floor space. " Clarify whether the counter space, which is indicated as H.C. accessible, is for seating or is for the point of sale cash register. If it is for seating provide similar space at the POS register. " Verify that the required accessible route between the booth/wall and the accessible counter, shall not be obstructed or reduced beyond the minimum width requirement, by either furniture or by persons seated or standing, at that counter. " Provide at least the minimum clear working space, at the electrical panel box per 2005 National Electrical Code, table 110.26(A)(1), as applicable. " Provide show window receptacle outlet(s) per NEC, Article 210.62 " Provide WPGFCI receptacle outlet(s) for HVACR equipment, including roof mounted, so that no piece of equipment is more than 25' from a receptacle outlet, per NEC, Article 210.63. " Revise plumbing riser diagrams to reflect any changes deemed necessary due to any reconfiguration(s) of the restroom(s). " Provide hot water to the restroom lavatories per FBC/Plumbing, section 607.1.1. " FYI: Natural gas supply is not available at this site. LP gas is typically used in this area. " Revise gas riser diagram to reflect and changes deemed necessary, to account for the use of LP gas. " Indicate LP gas tank location, size and whether tank is to be above ground or buried. " Resolve the discrepancy between HVAC Note # 2 and HVAC unit installation detail note #2. The minimum design wind speed at this site is 120 MPH. " Indicate method of condensate disposal. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
FI1 HOLD 04/24/2007 05/02/2007
Note: Held By: JMONTARULI Released By: JMONTARULI Held By: JPATTEE Automatic fire sprinkler relocations and additions will require submitted plans for review and approval. K class fire extinguisher placement does not comply with NFPA 10, section 5.7.2 Fire suppression system shall require seperate documents. Hood and duct installation shall require seperate documents.
UD1 HOLD 04/17/2007 04/18/2007
Note: Held By: JMONTARULI Released By: JMONTARULI Held By: CJOHNSON Held By: CJOHNSON 1. An additional grease interceptor will be required. The capacity of the grease interceptor is based 20 gallons per seat. The minimum volume of any grease interceptor shall be 750 gallons. 2. Additional capacity fees will need to be paid prior to the issuance of the CO
DSD COMPLETE 04/17/2007
Note: Released By: DRAMIREZ
UD1 COMPLETE 04/20/2007
Note: Released By: CJOHNSON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 11/07/2007
ADMIN FEE ¤20.00 05/29/2007
ELECTRIC FEE ¤60.00 05/29/2007
FIRE PLANS REVIEW ¤28.00 05/29/2007
MECHANICAL FEE ¤60.00 05/29/2007
PERMIT FEE ¤350.00 05/29/2007
PLAN CHECK FEE ¤100.00 05/29/2007
PLUMBING FEE ¤60.00 05/29/2007
Fees Total Due: ¤0.00 Total Paid: ¤718.00