I want to search for...
Permit #2007050023
Permit Details
Status: COED
| Parcel Id: 07-11-31-7065-00290-0080 |
| Block: 00290 |
| Subdivision: - |
| Job Phone: (386)447-0818 |
| Location Address: 3 KANKAKEE TRL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/11/2007 |
| NOC: RECORDED |
| Applicant name: GREGORY ALLAN NELSON |
| Owner: ANTHONY & JANICE PATRIZZ |
|
Address 203 RISLEY ROAD VERNON, CT 06066 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤230,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
HERITAGE HOMES OF PALM COAST INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12 PRINCESS KIM LANE PALM COAST, FL 32137 |
CBC1251716 (Exp: 09/30/2008) | (386)447-0818 | (386)447-0359 |
Sub Contractors
KENNETH J LOEPER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353782 PALM COAST, FL 32164 |
ES12000379 (Exp: 08/31/2010) | (386)931-5106 | (386)986-2272 |
THOMAS ALAN MOSE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1894 HOLLY HILL, FL 32117 |
CAC048082 (Exp: 08/31/2026) | 386-255-4545 | (386)252-4979 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/14/2007 | FINAL APPROVED | PGALLMANN |
| STORMWATER FINAL INSPECTION | 12/13/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 12 sq ft road damage $196 | |||
| STORMWATER FINAL INSPECTION | 12/12/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| UTILITY COMPANY FINAL | 12/11/2007 | APPROVED | PLAWRENCE |
| RESIDENTIAL EARLY POWER | 12/10/2007 | APPROVED | JHINDMAN |
| PRE DRIVEWAY | 12/03/2007 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION BUILDER TOLD ME HE WANTED A 7:30 INSPECTIONS . DRIVEWA NOT READY UNTILL 8:35 AM | |||
| PRE DRIVEWAY | 11/27/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SLOPE IS WAY OFF , ON RIGHT AND LEFT SIDE. NEED TO RE SET FORMS AND CALL GARY LALIMA IF NEEDED 386-931-0206 . | |||
| LATH /BRICK FLASHING | 10/24/2007 | APPROVED | DROCKWELL |
| INSULATION INSPECTION | 10/11/2007 | APPROVED | DROCKWELL |
| ALL ROUGH | 10/05/2007 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 09/26/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY! INCOMPLETE/PARTIAL LIST OF TEN ITEMS FOLLOW: 1) NAIL PLATES MISSING FOR ELECTRIC CABLE AT SEVERAL PLACES. 2) SUPPORT BAR FOR 4-GANG BOX IN POOL BATH IS NOT FASTENED. 3) PANCAKE BOX ON CEILING OF BREAKFAST NOOK IS SUPPORTED BY ONE DRYWALL SCREW ONLY. 4) SMURF CONDUIT USED IN PANEL FOR FUTURE. NOT ALLOWED PER NEC. 5) FAST TAPE USED FOR HANGERS ON EXHAUST FAN PIPING. ALSO, ELEVATION OF PIPING PUTS IT IN DIRECT CONTACT WITH CEILING, CAUSING VIBRATION. 6) EXHAUST FANS TERMINATE IN SOFFITS. MUST BE PIPED TO THE OUTSIDE. 7) FRAMING FOR POOL BATH SHOWER WALL IS NOT RIGID. SIDE TO SIDE MOVEMENT NOTED. 8) NAILERS FOR ENTRY ARCHES ARE NOT TAPCONED IN. 9) NON-TREATED LUMBER IS IN CONTACT WITH MASONRY AT SEVERAL LOCATIONS THROUGHOUT SOFFIT. 10) 1-1/2" WASTE ARM FOR LAVATORY IN FRONT RIGHT BATHROOM IS BACK-PITCHED. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/29/2007 | APPROVED - AS NOTED | DROCKWELL |
| Note: Check plans for GDR01 tie down at wall/Fireblock wall at bay | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/23/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: 1 1) GDRO1 NOT ANCHORD PER PLAN 2) HO1 NOT FASTENED @ BEARING WALL (2HETA20) 3) SHEATHING NOT COMPLETED IN MASTER BATH CLOSET AREA 4) BLOCKING NOT COMPLETED PER LAST INSPECTION 5) HIP TRUSS NOT STRAPED IN MASTER CLOSET 6) FRAMING NOT COMPLETED @ ENTRY TO MASTER BED ROOM 7) FIRE BLOCKING NOT COMPLETED IN DROPED CEILING AREAS 8) FINISH NAILING TRUSSES IN BUCKETS 9) GABLE STRAPS NOT NAILED INTO SOLID BLOCKING 10) DOOR JAM @ GARAGE BEARING WALL NOT STRAPED @ SOLE PLATE | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/21/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION TRUSSES NOT STRAPPED OR OFF-SET AT LINTEL(REAR BATH) / PROVIDE SOLID BLOCKING WHERE PLY CLIPS ARE MISSING OR WAY OFF CENTER/FIREBLOCKING MISSING AT DROP CEILINGS AND OUTSIDE WALL/INTERIOR WALLS OVER 10FT NEED BLOCKING AT MID-POINT/MISSING STUD AT ENTRY/FASTEN ALL GABLE STRAPS | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/01/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: Kelly called in inspection NOT READY. INCOMPLETE LIST FOLLOWS: 1) RIGID INSULATION IS BETWEEN FRAME TO CONCRETE BLOCK CONNECTIONS. 2) X BRACING IS MISSING FROM TWO OF THE GABLE ENDS. 3) 2"x 4" BLOCKING AT TOP OF FIRST TWO TRUSSES, SPACED 48" ON CENTER, MISSING AT ALL GABLE ENDS. 4) OTHER GABLE END BLOCKING MISSING. SEE GABLE DETAIL ON PAGE #4. 5) 2"x 4" RAFTERS INSTALLED AT CONVENTIONAL FRAMING. 2"x 8" SHOWN ON DETAIL, PAGE #4. ALSO, SIMPSON H25's MISSING. | |||
| LINTEL | 06/29/2007 | APPROVED | CMINI |
| Note: | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/28/2007 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/19/2007 | APPROVED | DROCKWELL |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 06/14/2007 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 11/07/2007 | 11/07/2007 |
| Note: Released By: WKINELL Received new topo survey/LGP with dw width revision.\\wk | |||
| BLD | COMPLETE | 08/14/2007 | 08/17/2007 |
| Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Truss repair. | |||
| SW1 | HOLD | 07/17/2007 | 07/17/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are higher than expected by 0.51ft.. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| BLD | COMPLETE | 05/11/2007 | 05/14/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 05/11/2007 | 05/11/2007 |
| Note: Released By: ECOYNE | |||
| ZON | HOLD | 05/10/2007 | 05/10/2007 |
| Note: Held By: ECOYNE need 5 index tress need roof pitch on plans | |||
| SW1 | COMPLETE | 05/01/2007 | 05/03/2007 |
| Note: Released By: LAPTEKAR address in system needs to reflect Kankakee address/front of house faces Kankakee//added DSD | |||
| ZON | HOLD | 05/01/2007 | 05/02/2007 |
| Note: Held By: ECOYNE need plant/tree schedule need to correct address - should be 8 Kankakee Trail |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤196.00 | 12/14/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 12/14/2007 |
| REINSPECTION FEE | ¤40.00 | 12/14/2007 |
| REINSPECTION FEE | ¤40.00 | 12/14/2007 |
| REINSPECTION FEE | ¤40.00 | 12/14/2007 |
| REINSPECTION FEE | ¤40.00 | 12/14/2007 |
| REVISION | ¤40.00 | 12/14/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/14/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/14/2007 |
| SW REVISION | ¤40.00 | 12/14/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/11/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/11/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/11/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/11/2007 |
| MECHANICAL FEE | ¤168.00 | 06/11/2007 |
| PERMIT FEE | ¤897.00 | 06/11/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/11/2007 |
| PLAN CHECK FEE | ¤92.00 | 06/11/2007 |
| PLUMBING FEE | ¤168.00 | 06/11/2007 |
| ADMIN FEE | ¤20.00 | 06/11/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/11/2007 |
| ELECTRIC FEE | ¤168.00 | 06/11/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,877.05 |