Permit #2007050023

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00290-0080
Block: 00290
Subdivision: -
Job Phone: (386)447-0818
Location Address: 3 KANKAKEE TRL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/11/2007
NOC: RECORDED
Applicant name: GREGORY ALLAN NELSON
Owner: ANTHONY & JANICE PATRIZZ

Address

203 RISLEY ROAD

VERNON, CT 06066

Lot: 0080
Contracted Stated Job Value: ¤230,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

HERITAGE HOMES OF PALM COAST INC.
Status Location Address State License Number Phone Fax
CANCEL

12 PRINCESS KIM LANE

PALM COAST, FL 32137

CBC1251716 (Exp: 09/30/2008) (386)447-0818 (386)447-0359

Sub Contractors

KENNETH J LOEPER
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353782

PALM COAST, FL 32164

ES12000379 (Exp: 08/31/2010) (386)931-5106 (386)986-2272
THOMAS ALAN MOSE
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 1894

HOLLY HILL, FL 32117

CAC048082 (Exp: 08/31/2026) 386-255-4545 (386)252-4979
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
JEFFREY JAY MITCHELL
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353178

PALM COAST, FL 32135

CCC1327078 (Exp: 08/31/2010) (386)437-3929 (386)447-2236

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 12/14/2007 FINAL APPROVED PGALLMANN
STORMWATER FINAL INSPECTION 12/13/2007 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION 12 sq ft road damage $196
STORMWATER FINAL INSPECTION 12/12/2007 Disapproved -FEE REQUIRED GLALIMA
UTILITY COMPANY FINAL 12/11/2007 APPROVED PLAWRENCE
RESIDENTIAL EARLY POWER 12/10/2007 APPROVED JHINDMAN
PRE DRIVEWAY 12/03/2007 APPROVED GLALIMA
Note: THIS IS A REINSPECTION BUILDER TOLD ME HE WANTED A 7:30 INSPECTIONS . DRIVEWA NOT READY UNTILL 8:35 AM
PRE DRIVEWAY 11/27/2007 Disapproved -FEE REQUIRED GLALIMA
Note: SLOPE IS WAY OFF , ON RIGHT AND LEFT SIDE. NEED TO RE SET FORMS AND CALL GARY LALIMA IF NEEDED 386-931-0206 .
LATH /BRICK FLASHING 10/24/2007 APPROVED DROCKWELL
INSULATION INSPECTION 10/11/2007 APPROVED DROCKWELL
ALL ROUGH 10/05/2007 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ALL ROUGH 09/26/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: NOT READY! INCOMPLETE/PARTIAL LIST OF TEN ITEMS FOLLOW: 1) NAIL PLATES MISSING FOR ELECTRIC CABLE AT SEVERAL PLACES. 2) SUPPORT BAR FOR 4-GANG BOX IN POOL BATH IS NOT FASTENED. 3) PANCAKE BOX ON CEILING OF BREAKFAST NOOK IS SUPPORTED BY ONE DRYWALL SCREW ONLY. 4) SMURF CONDUIT USED IN PANEL FOR FUTURE. NOT ALLOWED PER NEC. 5) FAST TAPE USED FOR HANGERS ON EXHAUST FAN PIPING. ALSO, ELEVATION OF PIPING PUTS IT IN DIRECT CONTACT WITH CEILING, CAUSING VIBRATION. 6) EXHAUST FANS TERMINATE IN SOFFITS. MUST BE PIPED TO THE OUTSIDE. 7) FRAMING FOR POOL BATH SHOWER WALL IS NOT RIGID. SIDE TO SIDE MOVEMENT NOTED. 8) NAILERS FOR ENTRY ARCHES ARE NOT TAPCONED IN. 9) NON-TREATED LUMBER IS IN CONTACT WITH MASONRY AT SEVERAL LOCATIONS THROUGHOUT SOFFIT. 10) 1-1/2" WASTE ARM FOR LAVATORY IN FRONT RIGHT BATHROOM IS BACK-PITCHED.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/29/2007 APPROVED - AS NOTED DROCKWELL
Note: Check plans for GDR01 tie down at wall/Fireblock wall at bay
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/23/2007 Disapproved -FEE REQUIRED JGIBSON
Note: 1 1) GDRO1 NOT ANCHORD PER PLAN 2) HO1 NOT FASTENED @ BEARING WALL (2HETA20) 3) SHEATHING NOT COMPLETED IN MASTER BATH CLOSET AREA 4) BLOCKING NOT COMPLETED PER LAST INSPECTION 5) HIP TRUSS NOT STRAPED IN MASTER CLOSET 6) FRAMING NOT COMPLETED @ ENTRY TO MASTER BED ROOM 7) FIRE BLOCKING NOT COMPLETED IN DROPED CEILING AREAS 8) FINISH NAILING TRUSSES IN BUCKETS 9) GABLE STRAPS NOT NAILED INTO SOLID BLOCKING 10) DOOR JAM @ GARAGE BEARING WALL NOT STRAPED @ SOLE PLATE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/21/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION TRUSSES NOT STRAPPED OR OFF-SET AT LINTEL(REAR BATH) / PROVIDE SOLID BLOCKING WHERE PLY CLIPS ARE MISSING OR WAY OFF CENTER/FIREBLOCKING MISSING AT DROP CEILINGS AND OUTSIDE WALL/INTERIOR WALLS OVER 10FT NEED BLOCKING AT MID-POINT/MISSING STUD AT ENTRY/FASTEN ALL GABLE STRAPS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/01/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: Kelly called in inspection NOT READY. INCOMPLETE LIST FOLLOWS: 1) RIGID INSULATION IS BETWEEN FRAME TO CONCRETE BLOCK CONNECTIONS. 2) X BRACING IS MISSING FROM TWO OF THE GABLE ENDS. 3) 2"x 4" BLOCKING AT TOP OF FIRST TWO TRUSSES, SPACED 48" ON CENTER, MISSING AT ALL GABLE ENDS. 4) OTHER GABLE END BLOCKING MISSING. SEE GABLE DETAIL ON PAGE #4. 5) 2"x 4" RAFTERS INSTALLED AT CONVENTIONAL FRAMING. 2"x 8" SHOWN ON DETAIL, PAGE #4. ALSO, SIMPSON H25's MISSING.
LINTEL 06/29/2007 APPROVED CMINI
Note:
FOUNDATION SURVEY APPROVED BY STORMWATER 06/28/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 06/19/2007 APPROVED DROCKWELL
Note:
FIRST ROUGH PLUMBING INSPECTION 06/14/2007 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/07/2007 11/07/2007
Note: Released By: WKINELL Received new topo survey/LGP with dw width revision.\\wk
BLD COMPLETE 08/14/2007 08/17/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Truss repair.
SW1 HOLD 07/17/2007 07/17/2007
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are higher than expected by 0.51ft.. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
BLD COMPLETE 05/11/2007 05/14/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON COMPLETE 05/11/2007 05/11/2007
Note: Released By: ECOYNE
ZON HOLD 05/10/2007 05/10/2007
Note: Held By: ECOYNE need 5 index tress need roof pitch on plans
SW1 COMPLETE 05/01/2007 05/03/2007
Note: Released By: LAPTEKAR address in system needs to reflect Kankakee address/front of house faces Kankakee//added DSD
ZON HOLD 05/01/2007 05/02/2007
Note: Held By: ECOYNE need plant/tree schedule need to correct address - should be 8 Kankakee Trail

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤196.00 12/14/2007
EARLY POWER INSPECTION ¤40.00 12/14/2007
REINSPECTION FEE ¤40.00 12/14/2007
REINSPECTION FEE ¤40.00 12/14/2007
REINSPECTION FEE ¤40.00 12/14/2007
REINSPECTION FEE ¤40.00 12/14/2007
REVISION ¤40.00 12/14/2007
STORMWATER REINSPECTION FEE ¤35.00 12/14/2007
STORMWATER REINSPECTION FEE ¤35.00 12/14/2007
SW REVISION ¤40.00 12/14/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 06/11/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/11/2007
STORM WATER PERMIT FEES ¤80.00 06/11/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 06/11/2007
MECHANICAL FEE ¤168.00 06/11/2007
PERMIT FEE ¤897.00 06/11/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 06/11/2007
PLAN CHECK FEE ¤92.00 06/11/2007
PLUMBING FEE ¤168.00 06/11/2007
ADMIN FEE ¤20.00 06/11/2007
ARC HOUSE REVIEW ¤125.00 06/11/2007
ELECTRIC FEE ¤168.00 06/11/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,877.05