I want to search for...
Permit #2007050078
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01160-0110 |
| CONDITIONED SPACE: 3292 sqft |
| GARAGE: 574 sqft |
| OPENED PORCH (WITH ROOF) : 140 sqft |
| Total Square Footage: 4006 sqft |
| Block: 01160 |
| Subdivision: - |
| Job Phone: (386)597-6809 |
| Location Address: 2 EDGELY LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/15/2007 |
| NOC: RECORDED |
| Owner: FULGENCIO R & MAGGIE GIL |
|
Address 8797 EL LAGO AVENUE FOUNTAIN VALLEY , CA 92708 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WEEKLEY HOMES,L.P.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
448 VICTORIA HILLS DRIVE DELAND, FL 32724 |
CBC053082 (Exp: 08/31/2012) | (386)775-7206 | (386)775-1709 |
Sub Contractors
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
ROBERT NATHANIEL PARKER III
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
875 JACKSON AVENUE WINTER PARK, FL 32789 |
EC0001858 (Exp: 08/31/2010) | (407)646-8700 | (407)647-8951 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/19/2007 | FINAL APPROVED | PGALLMANN |
| STORMWATER FINAL INSPECTION | 09/18/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: RORD DAMAGE 420.00 . | |||
| STORMWATER FINAL INSPECTION | 09/17/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: THIS IS A REINSPECTION SAME AS LAST INSPECTIONS , NO WORK PERFORMED | |||
| STORMWATER FINAL INSPECTION | 09/14/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: Remove dumpster. Replace sod across the street and adjacent left property swale. Clean road on right side. General cleanup. Remove all sprinklers from City property, must be 15 ft from road edge.\\wk | |||
| STORMWATER FINAL INSPECTION | 09/13/2007 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: This inspection cannot be scheduled///final surveys have not been submittedfor review/// | |||
| UTILITY COMPANY FINAL | 09/10/2007 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 09/07/2007 | Disapproved - NO FEE | MBACON |
| Note: FAILED, NO SOD OR FINAL GRADE | |||
| RESIDENTIAL EARLY POWER | 08/27/2007 | APPROVED | LHITES |
| Note: ADD STRAP TO RISER PIPE ABOVE SOFFIT | |||
| PRE DRIVEWAY | 08/21/2007 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 08/20/2007 | CANCELLED BY APPLICANT | LAPTEKAR |
| Note: THIS IS A REINSPECTION Mike not ready | |||
| PRE DRIVEWAY | 08/17/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: rebar missing, both sides.....cut road edge at a 90* cut not 45* [marked].....need 50% coverage of dirt, & 50% coverage of concrete over culvert pipe | |||
| PRE DRIVEWAY | 08/16/2007 | CANCELLED BY INSPECTOR | DRANDALL |
| LATH /BRICK FLASHING | 08/01/2007 | APPROVED | PGALLMANN |
| INSULATION INSPECTION | 07/31/2007 | APPROVED | ACOOPER |
| INSULATION INSPECTION | 07/30/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Unable to locate energy calcs, missing fireblocking between rear left bedroom and corner of rear bath, missing firebloking on right rear of the porch. | |||
| INSULATION INSPECTION | 07/27/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: NOT READY FOR INSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/26/2007 | APPROVED - AS NOTED | PGALLMANN |
| Note: OBTAIN REVISION FOR MODIFYING EJ7D TRUSSES. | |||
| ALL ROUGH | 07/26/2007 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/25/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: THIS IS A REINSPECTION... 1) AS THE EJ7D TRUSSES HAVE BEEN MODIFIED, NEED ENGINEER'S APPROVED METHOD OF REPAIR, APPROVED BY CITY'S PLAN REVIEW. 2) NEED SHIM AND UPLIFT STRAP WHERE MISSING ON B04. 3) FASTEN BACKSIDE OF STAIR LANDING TO A STRUCTURAL BEARING POINT ON EITHER SIDE. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/20/2007 | Disapproved - NO FEE | PGALLMANN |
| Note: THIS IS A REINSPECTION... REVISIONS NOT YET APPROVED BY CITY PLAN REVIEW. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/17/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Many items on original list not completed.Additional items posted at placcard | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/16/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Not ready for re-inspection | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/09/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY. INCOMPLETE LIST FOLLOWS: 1) MISSING NAILERS ON STEP DOWN TRUSSES. 2) FRONT BEARING POINT OF TRUSS FG01 IS NOT LOCATED AS PER PLAN. 3) LAM BEAM/S NOT STRAPPED AND/OR BOLTED AS PER PLAN. 4) FG01, GIRDER TO TOP PLATE STRAPPING IS NOT AS PER PLAN. 5) LAM BEAM MISSING UNDER UPSTAIRS BATH AREA. 6) ALL WOODEN TRUSS SHIMS MUST PROVIDE FULL BEARING. 7) PROVIDE APPROVED DETAIL FOR STAIRS AS INSTALLATION IS NOT PER PLAN. NOTE: LANDING AT UPPER LEVEL IS INADEQUATELY SUPPORTED. MOST NOTABLY THE DOUBLE 2"x12" HEADER IS NOT BUILT PER PLAN. 8) COLUMN UNDER STAIRS IS NOT INSTALLED PER PLAN. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/05/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: ALL ROOF METAL MUST BE IN PLACE AT THIS INSPECTION | |||
| TEMPORARY POLE | 07/02/2007 | APPROVED | LHITES |
| Note: Mike called in inspection | |||
| LINTEL | 06/27/2007 | APPROVED | CMINI |
| Note: | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/26/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/21/2007 | APPROVED | PGALLMANN |
| FIRST ROUGH PLUMBING INSPECTION | 06/19/2007 | APPROVED | DROCKWELL |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/27/2007 | 07/31/2007 |
| Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Truss Repair EJ70. | |||
| BLD | COMPLETE | 07/20/2007 | 07/24/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Chimney detail, truss repairs. | |||
| BLD | COMPLETE | 06/07/2007 | 06/07/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 05/16/2007 | 05/29/2007 |
| Note: Held By: JJOSEPH Stucco must be applied over the exterior wall while textured coating is not accetable. Indicate how the stucco will be applied ? | |||
| ZON | COMPLETE | 05/16/2007 | 05/16/2007 |
| Note: Released By: ECOYNE | |||
| SW1 | COMPLETE | 05/02/2007 | 05/07/2007 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 05/02/2007 | 05/04/2007 |
| Note: Held By: ECOYNE Need banding around windows right elevation facing Edgewater Dr. | |||
| BLD | HOLD | 05/31/2007 | |
| Note: Held By: JJOSEPH 1.Please provide beam post connectors 2.The beam size sheet must be signed and sealed. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤420.00 | 09/20/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REINSPECTION FEE | ¤40.00 | 09/20/2007 |
| REVISION | ¤40.00 | 09/20/2007 |
| REVISION | ¤40.00 | 09/20/2007 |
| ADDITIONAL FEE | ¤80.00 | 09/20/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/20/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/20/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/20/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/15/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/15/2007 |
| BUILDING CODE ADMIN FUND | ¤20.03 | 06/15/2007 |
| ELECTRIC FEE | ¤430.80 | 06/15/2007 |
| ADDITIONAL FEE | ¤40.00 | 06/15/2007 |
| ADDITIONAL FEE | ¤80.00 | 06/15/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/15/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/15/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/15/2007 |
| MECHANICAL FEE | ¤430.80 | 06/15/2007 |
| PERMIT FEE | ¤2,410.20 | 06/15/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/15/2007 |
| PLAN CHECK FEE | ¤247.20 | 06/15/2007 |
| PLUMBING FEE | ¤430.80 | 06/15/2007 |
| RADON FEE | ¤20.03 | 06/15/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,972.91 |