I want to search for...

Permit #2007050503

Permit Details

Status: COED

Parcel Id: 07-11-31-7060-00410-0180
CONDITIONED SPACE: 3004 sqft
GARAGE: 402 sqft
OPENED PORCH (WITH ROOF) : 132 sqft
Total Square Footage: 3538 sqft
Block: 00410
Subdivision: -
Job Phone: (904)296-1490
Location Address: 11 SQUANTO PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/27/2007
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES, INC

Address

11200 ST. JOHNS INDUSTRIAL PKWY, N

JACKSONVILLE, FL 32246

Address

#2

JACKSONVILLE, FL 32246

Lot: 0180
Contracted Stated Job Value: ¤126,810.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

HARRY DANIEL LONG JR
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

955 KELLIER ROAD

ALTAMONTE SPRINGS, FL 32714

SUITE 1500

ALTAMONTE SPRINGS, FL 32714

EC0000726 (Exp: 08/31/2020) (407)333-1500 (407)320-1957
GARY CARMACK
Status State License Number
CANCEL CAC043900 (Exp: 08/31/2010)
JULIA H CREESE
Status Location Address State License Number Phone Fax
CANCEL

927 CASCADES PARK TRAIL

SANFORD, FL 32771

CFC1426702 (Exp: 08/31/2010) (407)333-1509 (407)320-1957
EUGENIA MAY MILHOLEN
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 2088

Bunnell, FL 32110

CCC048174 (Exp: 08/31/2010) (386) 437-6457 (386)437-6457

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 12/18/2007 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 12/13/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: HOUSE LOCKED. NOTE: AS THERE IS ONLY ONE HARDWOOD TREE PLANTED, PROVIDE APPROVED LANDSCAPE PLAN FOR FINAL INSPECTION.
STORMWATER FINAL INSPECTION 12/11/2007 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 12/10/2007 Disapproved -FEE REQUIRED GLALIMA
UTILITY COMPANY FINAL 12/06/2007 APPROVED MBACON
PRE DRIVEWAY 11/27/2007 APPROVED GLALIMA
RESIDENTIAL EARLY POWER 11/21/2007 APPROVED PGALLMANN
INSULATION INSPECTION 10/19/2007 APPROVED DROCKWELL
ALL ROUGH 10/16/2007 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 10/16/2007 APPROVED JGIBSON
ALL ROUGH 10/11/2007 Disapproved -FEE REQUIRED JGIBSON
Note: THIS IS A REINSPECTION AS MENTIONED IN PREVIOUS INSPECTION FIRE BLOCKING STILL NOT COMPLETED AT FLOOR SEPERATION ON FIRST FLOOR TO SECOND FLOOR.
ALL ROUGH 10/09/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION AS MENTIONED LAST INSPECTION-BLOCKING MISSING CENTER WALL/NAILERS MISSING IN CORNERS FOR DRYWALL-UP BATH TO TOILET/SHOWER. ALSO-PROTECT PLUMBING VENT STACK OR FURR WALL DOWN BATH.DON`T FORGET NAILERS IN CORNER IF YOU FURR OUT.
ALL ROUGH 10/03/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: DUPLEX RECEPT.BOX AT HALL TO KITCHEN EXCEEDS BOX FILL ALLOWANCE/WIRE AT KITCHEN FLOOR NEEDS 6`` SLEEVE/MISSING BLOCKING AT CENTER WALL/INSTALL NAILERS FOR DRYWALL UP MASTER BATH.
EXTERIOR WALL SHEATHING/SHEAR WALL 09/28/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/28/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING/SHEAR WALL 09/26/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: SHEATHING IS NOT NAILED OFF PROPERLY TO JOIST WEBS THE FIRST 16" UP FROM BLOCK.JOINTS MUST BREAK AT SOLID BLOCKING AND BE NAILED TO PLAN.STRAPING MUST BE ATTACHED TO SOLID BLOCKING NOT OSB.MUST CHECK BEFORE LATH.CHECK ALL JOINTS FOR NAILING.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/24/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: WALL SHEATHING MUST BE COMPLETED FIRST.EXPOSE NAIL PATTERNS FOR INSPECTOR.
LINTEL 09/05/2007 APPROVED PGALLMANN
FOUNDATION SURVEY APPROVED BY STORMWATER 09/04/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 08/27/2007 APPROVED DROCKWELL
FIRST ROUGH PLUMBING INSPECTION 08/24/2007 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 07/02/2007 07/05/2007
Note: Released By: FREODICA Reviewed by F. Reodica Released per LW.
ZON COMPLETE 05/30/2007 05/30/2007
Note: Released By: ECOYNE
BLD HOLD 05/30/2007 05/30/2007
Note: Held By: FREODICA 1. Submit two (2) copies of sheet FDO ( Second Floor Framing ) which are missing in the submitted package.
SW1 COMPLETE 05/23/2007
Note: Released By: LAPTEKAR
ZON HOLD 05/22/2007
Note: Held By: ECOYNE Need 4 index trees

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 12/19/2007
REINSPECTION FEE ¤40.00 12/19/2007
REINSPECTION FEE ¤40.00 12/19/2007
REINSPECTION FEE ¤40.00 12/19/2007
REINSPECTION FEE ¤40.00 12/19/2007
REINSPECTION FEE ¤40.00 12/19/2007
REINSPECTION FEE ¤40.00 12/19/2007
STORMWATER REINSPECTION FEE ¤35.00 12/19/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 07/27/2007
ADMIN FEE ¤20.00 07/27/2007
ARC HOUSE REVIEW ¤125.00 07/27/2007
BUILDING CODE ADMIN FUND ¤17.69 07/27/2007
ELECTRIC FEE ¤196.20 07/27/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 07/27/2007
STORM WATER PERMIT FEES ¤80.00 07/27/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 07/27/2007
MECHANICAL FEE ¤196.20 07/27/2007
PERMIT FEE ¤1,080.30 07/27/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 07/27/2007
PLAN CHECK FEE ¤110.80 07/27/2007
PLUMBING FEE ¤196.20 07/27/2007
RADON FEE ¤17.69 07/27/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,968.13