I want to search for...
Permit #2007050665
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01130-0110 |
| CONDITIONED SPACE: 3314 sqft |
| GARAGE: 765 sqft |
| OPENED PORCH (WITH ROOF) : 453 sqft |
| OPENED PORCH (WITH ROOF) : 46 sqft |
| Total Square Footage: 4578 sqft |
| Block: 01130 |
| Subdivision: - |
| Job Phone: (386) 445-4747 |
| Location Address: 25 EDGEWATER DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/14/2007 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: MESICS JOSEPH & MARY ANN TRUSTEES |
|
Address 14 ASSISCUNK DRIVE COLUMBUS, NJ 08022 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤480,690.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Sub Contractors
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
JEFFREY EUGENE COOK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 BARCO ROAD ST AUGUSTINE, FL 32086 |
EC13002583 (Exp: 08/31/2026) | 904-424-2491 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| GAS FINAL | 05/16/2008 | APPROVED | MMOORE |
| FINAL COMPLETE BUILDING INSPECTION | 05/16/2008 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 05/15/2008 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION NO PLANS, BOND GENERATOR, VENT REGULATOR, CALL IN AGAIN FOR FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION | 05/14/2008 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: CANCELLED BY WILLIAM | |||
| UTILITY COMPANY FINAL | 05/01/2008 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 04/29/2008 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 40 SF Road Damage = $420.00 | |||
| STORMWATER FINAL INSPECTION | 04/28/2008 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: WENT OVER LIST WITH BUILDER . GRADE / SOD AT ROAD EDGE OF ROAD . TRASH. | |||
| RESIDENTIAL EARLY POWER | 04/17/2008 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 03/20/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: OPENING IN PANEL NEEDS TO BE EFFECTIVELY CLOSED. 2IN HOLE DRILLED INTO THE SIDE OF THE ENCLOSURE. | |||
| PRE DRIVEWAY | 03/17/2008 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 11/21/2007 | APPROVED - AS NOTED | ACOOPER |
| Note: ENERGY CALCS. TO BE RESUBMITTED AND APPROVED FOR GAS OPERATED WATER HEATER PRIOR TO ANOTHER INSPECTION. | |||
| GAS ROUGH | 11/19/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| GAS ROUGH | 11/14/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: THIS IS A REINSPECTION... NEED CITY`S STAMP OF APPROVAL ON A RISER DIAGRAM, NOTABLY TO VERIFY 3/4" RUNNING 95 FEET +/- TO THE WATER HEATER. NOTE: PROVIDE PLAN REVIEW AND JOB BOX WITH GAS FIRED EQUIPMENT SPECIFICATIONS. | |||
| ALL ROUGH | 11/13/2007 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 11/09/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION STILL NEED TO GROUND COACH LIGHT BOX AND CLOSE UNUSED OPENING. THERE ARE UNUSED OPENINGS IN HOUSE AT ENCLOSURES. FAN BOX IN REAR BEDROOM IS GOING TO BE BURIED. NEED FIRE BLOCKING UNDER STAIRS. OUTER INSULATION OF NM CABLE NEEDS TO ENTER ENCLOSURE.25IN. STILL NEED TO INSTALL ATTIC LIGHT. BOX AT UPSTAIRS IS NOTED AS 23CU.IN. CONDUCTOR FILL IS ACTUALLY 24CU.IN. NAIL PLATE SER AT PANEL IN INTERIOR ROOM. MASTER BEDROOM SWITCH MARK WHITE CONDUCTOR BEING USED AS A HOT CONDUCTOR. ITEMS PREVIOUSLY NOTED HAVE NOT BEEN COMPLETED. NOT READY | |||
| ALL ROUGH | 11/02/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: THIS IS A REINSPECTION NOT READY | |||
| GAS ROUGH | 11/02/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: THIS IS A REINSPECTION NOT READY | |||
| ALL ROUGH | 11/01/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: GROUND ALL METAL BOXES.( COACH LIGHT) CLOSE ALL UNUSED OPENINGS IN BOXES. INSTALL ATTIC LIGHT. NAIL PLATES MISSING IN MULTIPLE LOCATIONS. EXHAUST VENT PITCHED IN WRONG DIRECTION AT 2 LOCATIONS. COMPLETE A/C DUCTWORK CHANGES IN REAR BEDROOM. | |||
| GAS ROUGH | 11/01/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NEED RISER DIAGRAM FOR GAS ROUGH. | |||
| LATH /BRICK FLASHING | 09/21/2007 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/18/2007 | APPROVED - AS NOTED | PGALLMANN |
| Note: CHECK @ ALL ROUGH... 1) REMOVE RIGID INSULATION AT DROP CEILINGS AND FIREBLOCK. 2) FIREBLOCK TOP OF ARCHES. 3) CONTINUOUS BRIDGING (RAT RUNS) NEED TO TIEOFF AT LAST TRUSS. 4) NAIL SP2`S AT TOP PLATES, PER MANUFACTURER`S SPECIFICATIONS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/17/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION ITEMS 1 AND 6 NOT REPAIRED PER LAST INSPECTION.REMOVE INSULATION BOARD AT DROP CEILINGS AND FIREBLOCK/FIREBLOCK TOP OF ARCHES/RAT RUNS NEED TO TIE OFF AT LAST TRUSS/REPAIR STRAPS AT PIGGY BACKS/STRAPS AT CANTILEVERED POST TO BEAM NOT LENGTH TO PLAN/NAIL SP2`S AT TOP PLATES TO MANUFACTURED SPECS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/14/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION 1. FILL EMPTY CELL IN REAR..2. STRAP NOT NAILED FROM STUD TO BEAM OVER KITCHEN PANTRY. 3. MISSING NAILS IN VALLEY STRAPS. 4. NEED TO ORGANIZE ENGINEERING SHEETS,SEAMS TO BE MISSING TRUSS SHEETS. 5 NEED TO ENGINEER DRILLED HOLES THROUGH TOP AND BOTTOM PLATES 2ND FL BATH. 6. NEED TRUSS REPAIR ON BROKEN TRUSS T-52. 7. PLAN CALLS FOR 3.2X4 SPF UNDER TRUSS T-38,ALSO UNDER BM#3 CALLS FOR 3.2X4 SPF.. 8. NEED REVISIONS FOR 2X4 WALLS THAT PLAN CALLS FOR 2X6 WALLS...9. MISSING BEARING POINT UNDER CANTILLEVERED BEAM,LETTER C ON LOAD PATH SCHEDULE.. 10 RAT RUNS NEED TO OVER LAP TWO TRUSSES. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/07/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: TRUSS STRAPS MISALLIGNED OR UNDER TRUSSES AT MID BEARING POINT/SHOW ENGINNERING FOR 5FT+ CANTILLEVERED FLOOR BEAM/VENT FOR BATH THRU TOP PLATE EXCEEDS CODE(UP BATH) /MISSING BUCKET AT PG04/ALL ROOF METALS INSTALLED BY THIS INSPECTION/FIREBLOCKING UNDER STAIRS AT OUTSIDE WALL....INCOMPLETE INSPECTION | |||
| LINTEL | 08/06/2007 | APPROVED | PGALLMANN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 08/03/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/17/2007 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 07/13/2007 | APPROVED | DROCKWELL |
| TEMPORARY POLE | 07/13/2007 | APPROVED | LHITES |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/08/2008 | 05/08/2008 |
| Note: Released By: JMCGOWEN gas tank location | |||
| ZON | COMPLETE | 05/08/2008 | 05/08/2008 |
| Note: Released By: ECOYNE generator placement | |||
| MECH | HOLD | 04/15/2008 | 04/15/2008 |
| Note: Held By: JMCGOWEN provide revised gas riser diagram to show added generator , also provide site plan plan with size and location of L/P tank. | |||
| SW1 | COMPLETE | 03/12/2008 | 03/12/2008 |
| Note: Released By: LAPTEKAR Updated driveway detail and site plan to reflect concrete driveway with border of 2 1/2" pavers. | |||
| BLD | COMPLETE | 11/15/2007 | 11/16/2007 |
| Note: Released By: FREODICA Rev.- Added propane gas riser for grill, fireplace and water heater. No gas tank or underground piping. | |||
| BLD | COMPLETE | 07/12/2007 | 07/13/2007 |
| Note: Released By: FREODICA Released per LW. Revisions - Interior footer on sheet S-1, wood LVL at lanai to precast lintel on sheet S1.1. | |||
| BLD | COMPLETE | 06/12/2007 | 06/14/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 06/12/2007 | 06/12/2007 |
| Note: Released By: ECOYNE | |||
| SW1 | COMPLETE | 06/12/2007 | 06/12/2007 |
| Note: Released By: WKINELL Builder came in with new LGP.//wk | |||
| SW1 | COMPLETE | 06/11/2007 | 06/12/2007 |
| Note: Released By: MDEFREITAS Held By: WKINELL Need erosion control measures inspected prior to beginning work in the area of the rear and right property lines. Inspection hold has been placed on this permit until SW Inspector approves proper installation of erosion control measures along the rear and right property lines to prevent silt accumulation in the right ditch, rear waterway and stormwater collection structure. Please submit an adequate lot grading plan that demonstrates stormwater drainage to the front swale prior to discharging into the SW spillway. Culvert pipe invert elevations, proposed swale elevations and road center line elevations must be shown, in addition to proposed grade elevations on the property and adjacent locations. LGP that was submitted is illegible (due to size) and does not include required information.//wk | |||
| ZON | COMPLETE | 05/24/2007 | 05/25/2007 |
| Note: Released By: MDEFREITAS Held By: JGONZALEZ reviewed 06-11-07 ECOYNE: need breakdown sqft calculation for 1st floor, 2nd floor. concrete patio and a/c pad look is in 20' utility easement nothing is permited in a 20ft easement need site plan reduced for zoning sign off need pool & deck off plans or to state "proposed" |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤420.00 | 05/16/2008 |
| EARLY POWER INSPECTION | ¤40.00 | 05/16/2008 |
| EARLY POWER INSPECTION | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REINSPECTION FEE | ¤40.00 | 05/16/2008 |
| REVISION | ¤40.00 | 05/16/2008 |
| REVISION | ¤40.00 | 05/16/2008 |
| ADDITIONAL FEE | ¤40.00 | 05/16/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/16/2008 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/14/2007 |
| ADMIN FEE | ¤20.00 | 06/14/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/14/2007 |
| BUILDING CODE ADMIN FUND | ¤22.89 | 06/14/2007 |
| ELECTRIC FEE | ¤318.60 | 06/14/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/14/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/14/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/14/2007 |
| MECHANICAL FEE | ¤318.60 | 06/14/2007 |
| PERMIT FEE | ¤1,875.90 | 06/14/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/14/2007 |
| PLAN CHECK FEE | ¤192.40 | 06/14/2007 |
| PLUMBING FEE | ¤318.60 | 06/14/2007 |
| RADON FEE | ¤22.89 | 06/14/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,002.93 |