Permit #2007050685
Permit Details
Status: COED
| Parcel Id: 07-11-31-7060-00400-0030 |
| CONDITIONED SPACE: 2044 sqft |
| GARAGE: 444 sqft |
| OPENED PORCH (WITH ROOF) : 25 sqft |
| OPENED PORCH (WITH ROOF) : 160 sqft |
| Total Square Footage: 2673 sqft |
| Block: 00400 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 5 SQUIRREL PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/14/2007 |
| NOC: RECORDED |
| Applicant name: GREGORY JOSEPH SEAL |
| Owner: MASTERPIECE HOMES |
|
Address 4721 E MOODY BLVD BUNNELL, FL 32110 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤134,677.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MASTERPIECE HOMES INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 740618 ORANGE CITY, FL 32763 |
CRC1327666 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 11/21/2007 | FINAL APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 11/19/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: if rear buffer has been cleared backing sesame blvd landscaping is required around rear of house and wrap around rear corners. ARCH FAULT NEEDS TO B E IN ALL BED ROOMS { MASTER BEDROOM SUITE}, A/C CONDENSER NOT LEVEL, CARRIAGE LIGHTS NOT ATTACHED SECURELY, RETURN IN GARAGE NOT PER CODE FLEX DUCT NOT PERMISSABLE. | |||
| UTILITY COMPANY FINAL | 11/16/2007 | APPROVED | TSCHWEERS |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 11/14/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: Clean road on right side of DW. Remove concrete on side of back porch.\\wk | |||
| UTILITY COMPANY FINAL | 11/09/2007 | Disapproved - NO FEE | MBACON |
| Note: No electric to pep panel. | |||
| PRE DRIVEWAY | 10/24/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: CALL GARY BEFOR POUR | |||
| RESIDENTIAL EARLY POWER | 10/23/2007 | APPROVED | LHITES |
| INSULATION INSPECTION | 09/11/2007 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 09/10/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: 3/4`` GAP ALONG LENGTH AT TOP OF ARCHE`S OPEN INTO ATTIC-DRAFTSTOP | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/06/2007 | CANCELLED BY APPLICANT | AIRS WEB |
| ALL ROUGH | 09/06/2007 | APPROVED - AS NOTED | DROCKWELL |
| Note: NEED KO TOP OF PANEL/SEPARATE WIRES WHERE MORE THAN 3 TOGETHER MORE THAN 2FT(BUNDLING ISSUE) | |||
| LATH /BRICK FLASHING | 09/05/2007 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/23/2007 | APPROVED | DROCKWELL |
| LINTEL | 08/16/2007 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 08/15/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: #5 BAR MUST BE HUNG IN CENTER OF POWER BOX LINTEL. ALSO, MUST BE RIGID ENOUGH TO WITHSTAND POUR. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 08/14/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 08/08/2007 | APPROVED | PGALLMANN |
| FIRST ROUGH PLUMBING INSPECTION | 08/06/2007 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/05/2007 | 06/07/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 05/30/2007 | 05/31/2007 |
| Note: Held By: FREODICA 1. Please revise all details/sections that indicate the word "Decorative Cementitous Coating" and replace them with " Stucco" and indicate the number of layers, thickness and method of application for both wooden frame and masonry walls per FRC 2005 supplement Table 703.11. Below is for your information. In the 2005 supplement section R703.11 Weather protection was added to the residential code. At this time the City started adding comment notes to the drawings stating: All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Decorative Cementituous Coating is not an approved covering over wood sheathing, however stucco is acceptable if applied per ASTM C926 and the following criteria: a. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. b. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. c. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. In the 2006 supplement section 1403.2 was modified to state " that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls" This means that, decorative cementituous coating CAN NOT, be used over exterior masonry walls, unless the block can be shown to be non-porous. Based on this information the drawings should list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section. | |||
| ZON | COMPLETE | 05/25/2007 | 05/29/2007 |
| Note: Released By: JGONZALEZ | |||
| SW1 | COMPLETE | 05/31/2007 | |
| Note: Released By: LAPTEKAR |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 12/28/2007 |
| REINSPECTION FEE | ¤40.00 | 12/28/2007 |
| REINSPECTION FEE | ¤40.00 | 12/28/2007 |
| REINSPECTION FEE | ¤40.00 | 12/28/2007 |
| ADDITIONAL FEE | ¤40.00 | 07/26/2007 |
| ADMIN FEE | ¤20.00 | 06/14/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/14/2007 |
| BUILDING CODE ADMIN FUND | ¤13.37 | 06/14/2007 |
| ELECTRIC FEE | ¤148.80 | 06/14/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/14/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/14/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/14/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/14/2007 |
| MECHANICAL FEE | ¤148.80 | 06/14/2007 |
| PERMIT FEE | ¤772.20 | 06/14/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/14/2007 |
| PLAN CHECK FEE | ¤79.20 | 06/14/2007 |
| PLUMBING FEE | ¤148.80 | 06/14/2007 |
| RADON FEE | ¤13.37 | 06/14/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,362.59 |