I want to search for...

Permit #2007050686

Permit Details

Status: COED

Parcel Id: 07-11-31-7060-00460-0160
CONDITIONED SPACE: 2020 sqft
GARAGE: 461 sqft
OPENED PORCH (WITH ROOF) : 180 sqft
OPENED PORCH (WITH ROOF) : 98 sqft
Total Square Footage: 2759 sqft
Block: 00460
Subdivision: -
Job Phone: (386)775-4137
Location Address: 16 SQUASH BLOSSOM TRL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/14/2007
NOC: RECORDED
Applicant name: GREGORY JOSEPH SEAL
Owner: MASTERPIECE HOMES, INC

Address

4721 E. MOODY BLVD UNIT 5

BUNNELL, FL 32110

Address

BLDG 504

BUNNELL, FL 32110

Lot: 0160
Contracted Stated Job Value: ¤128,896.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MASTERPIECE HOMES INC
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 740618

ORANGE CITY, FL 32763

CRC1327666 (Exp: 08/31/2010) (386)775-4137 (386)775-1397

Sub Contractors

EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
JEFFREY JAY MITCHELL
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353178

PALM COAST, FL 32135

CCC1327078 (Exp: 08/31/2010) (386)437-3929 (386)447-2236
PETER JOSEPH LYDEN
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 1009

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2014) (386) 931-2568 386-313-3445

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/16/2007 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 11/14/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: if reserve parcel cleared landscaping is required around rear of property at 3ft on center 3ft in hieght. N/A, AS OF INSPECTION OF 11-14-07. 1) GFCI RECEPTACLES AT EITHER SIDE OF KITCHEN SINK ARE TOO FAR AWAY FROM SINK. CODE CALLS FOR 24" MAXIMUM. 2) FRONT DOOR WILL NOT LATCH.
STORMWATER FINAL INSPECTION 11/13/2007 APPROVED GLALIMA
UTILITY COMPANY FINAL 11/09/2007 APPROVED MBACON
PRE DRIVEWAY 10/23/2007 APPROVED GLALIMA
RESIDENTIAL EARLY POWER 10/23/2007 APPROVED - AS NOTED LHITES
Note: CHECK OUTLET SPACING OF KITCHEN COUNTER TOP PER 210.52 WITHIN 2` OF SINK
INSULATION INSPECTION 09/04/2007 APPROVED DROCKWELL
ALL ROUGH 08/30/2007 APPROVED - AS NOTED DROCKWELL
LATH /BRICK FLASHING 08/29/2007 APPROVED DROCKWELL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/23/2007 APPROVED DROCKWELL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/20/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: SIMPSON MST 37 PER JACK FLOOR TO FLOOR/SIMPSON LSTA 30 AT 48`` O/C /FIREBLOCK DROP CEILING ABOVE WINDOWS LIVING ROOM/STRAP HEADER ABOVE ENTRY/STRAP HAND FRAMING TO TRUSSES BELOW
EXTERIOR WALL SHEATHING/SHEAR WALL 08/14/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING/SHEAR WALL 08/10/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: Not ready for inspection.
LINTEL 08/07/2007 APPROVED DROCKWELL
FOUNDATION SURVEY APPROVED BY STORMWATER 08/06/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 07/31/2007 APPROVED DROCKWELL
FIRST ROUGH PLUMBING INSPECTION 07/27/2007 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 06/07/2007 06/07/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 05/30/2007 05/31/2007
Note: Held By: JJOSEPH The elevation plans indicate that stucco will be applied over the exterior wall whereas the wall section shows decorative cementitious coating. Please revise the plans to match up the elevation to the wall section. (References: 2005 supplement section R703.2.1,R703.6 & table R703.11 and 2006 supplement) Note: 3 layers of approved water resistive barrier, not 2 layers please make correction
ZON COMPLETE 05/25/2007 05/29/2007
Note: Released By: JGONZALEZ Held By: ECOYNE
SW1 COMPLETE 05/31/2007
Note: Released By: LAPTEKAR

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 12/11/2007
REINSPECTION FEE ¤40.00 12/11/2007
REINSPECTION FEE ¤40.00 12/11/2007
REINSPECTION FEE ¤40.00 12/11/2007
ADDITIONAL FEE ¤40.00 07/26/2007
ADMIN FEE ¤20.00 06/14/2007
ARC HOUSE REVIEW ¤125.00 06/14/2007
BUILDING CODE ADMIN FUND ¤13.80 06/14/2007
ELECTRIC FEE ¤149.40 06/14/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/14/2007
STORM WATER PERMIT FEES ¤80.00 06/14/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 06/14/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 06/14/2007
MECHANICAL FEE ¤149.40 06/14/2007
PERMIT FEE ¤776.10 06/14/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 06/14/2007
PLAN CHECK FEE ¤79.60 06/14/2007
PLUMBING FEE ¤149.40 06/14/2007
RADON FEE ¤13.80 06/14/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,369.55