I want to search for...

Permit #2007050693

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01230-0130
CONDITIONED SPACE: 2846 sqft
GARAGE: 460 sqft
OPENED PORCH (WITH ROOF) : 155 sqft
OPENED PORCH (WITH ROOF) : 31 sqft
Total Square Footage: 3492 sqft
Block: 01230
Subdivision: -
Job Phone: (386)775-4137
Location Address: 229 BIRD OF PARADISE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/06/2007
NOC: RECORDED
Applicant name: GREGORY JOSEPH SEAL
Owner: HULLFISH DAVID R & MARIA

Address

623 GRAND ST

TRENTON, NJ 08610

Lot: 0130
Contracted Stated Job Value: ¤157,609.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MASTERPIECE HOMES INC
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 740618

ORANGE CITY, FL 32763

CRC1327666 (Exp: 08/31/2010) (386)775-4137 (386)775-1397

Sub Contractors

EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
JEFFREY JAY MITCHELL
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353178

PALM COAST, FL 32135

CCC1327078 (Exp: 08/31/2010) (386)437-3929 (386)447-2236
PETER JOSEPH LYDEN
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 1009

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2014) (386) 931-2568 386-313-3445

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 01/04/2008 FINAL APPROVED ACOOPER
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 01/03/2008 Disapproved -FEE REQUIRED ACOOPER
Note: THIS IS A REINSPECTION ADD BUSHING TO A//C DISCONNECT (EXTERIOR), RE-IDENTIFY WHITE USED AS HOT IN THE A/C DISCONNECT, ADD POWER IN UPSTAIRS BEDROOM HALLWAY TO ARC FAULT BREAKERS.
FINAL COMPLETE BUILDING INSPECTION 12/14/2007 Disapproved -FEE REQUIRED ACOOPER
Note: ADD BUSHING TO A/C DISCONNECT (EXTERIOR), RE IDENTIFY WHITE USED AS HOT IN A/C DISCONNECT, FINISH PAINTING AND SEALING WINDOWS, BOOT TO MAIN POWER NOT INTEGRATED WITH SHINGLES, ADD POWER IN HALLWAY FOR MASTER BATH TO ARC FAULT BREAKERS (OR ADD DOOR)
UTILITY COMPANY FINAL 12/10/2007 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 12/05/2007 APPROVED DRANDALL
RESIDENTIAL EARLY POWER 12/04/2007 APPROVED LHITES
PRE DRIVEWAY 11/15/2007 APPROVED DRANDALL
INSULATION INSPECTION 10/16/2007 APPROVED MMOORE
ALL ROUGH 10/12/2007 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ALL ROUGH 10/11/2007 Disapproved -FEE REQUIRED JGIBSON
Note: SEPERATE GROUND AND NEUTRALS IN PANEL UNDER TERMANAL SCREW, MISSING KO`S IN A COUPLE AREAS CHECK ALL NAIL PLATES AND RENAIL ROMEX WHERE STAPLED ON EDGE AND CHECK SERVICE CONDUCTERS FOR OVER SCARING ON ALUMINUM,STRAP ROMEX EVERY 4.5 WHERE NEEDED IN CEILING, ALL UNUSED OPENIGS NEED TO BE CLOSED. CHECK INSULATION BEHIND TUB SHOWER COMBO IN DOWNSTAIRS BATH.
LATH /BRICK FLASHING 10/05/2007 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/24/2007 APPROVED MMOORE
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING/SHEAR WALL 09/19/2007 APPROVED CMINI
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING/SHEAR WALL 09/18/2007 Disapproved -FEE REQUIRED MMOORE
Note: 1. RENAIL EXTERIOR SHEATHING TO THE APPROVED NAIL PATTERN AS SHOWN IN DETAIL IN PLANS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/17/2007 Disapproved - NO FEE MMOORE
Note: !. ROOF IS OPEN AND NOT SHEATHED IN 2. NOT READY FOR SHEATHING INSP.
LINTEL 09/10/2007 APPROVED CMINI
Note: THIS IS A REINSPECTION
LINTEL 09/07/2007 Disapproved -FEE REQUIRED CMINI
Note: NEED TO HAVE APPROVED PLANS ON JOB FOR INSPECTION. CHARLIE..931-1251
FOUNDATION SURVEY APPROVED BY STORMWATER 09/06/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 08/30/2007 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 08/24/2007 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 06/26/2007 06/27/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 COMPLETE 06/08/2007 06/11/2007
Note: Released By: WKINELL
ZON COMPLETE 05/30/2007 05/30/2007
Note: Released By: ECOYNE
BLD HOLD 05/30/2007 06/01/2007
Note: Held By: JJOSEPH The elevation plans indicate that stucco will be applied over the exterior wall whereas the wall section shows decorative cementitious coating. Please revise the plans to match up the elevation to the wall section. (References: 2005 supplement section R703.2.1,R703.6 & table R703.11 and 2006 supplement) Note: 3 layers of approved water resistive barrier, not 2 layers please make correction
SW1 HOLD 05/25/2007 05/29/2007
Note: Held By: WKINELL Topo survey/ LGP outdated, survey shows lot 14 cleared, our records indicate a house has been CO'ed on lot 14. Please submit updated topo survey/LGP that reflects current conditions.//wk
ZON HOLD 05/25/2007 05/29/2007
Note: Held By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 01/07/2008
REINSPECTION FEE ¤40.00 01/07/2008
REINSPECTION FEE ¤40.00 01/07/2008
REINSPECTION FEE ¤40.00 01/07/2008
REINSPECTION FEE ¤40.00 01/07/2008
REINSPECTION FEE ¤40.00 01/07/2008
ADDITIONAL FEE ¤40.00 01/07/2008
ADMIN FEE ¤20.00 07/06/2007
ARC HOUSE REVIEW ¤125.00 07/06/2007
BUILDING CODE ADMIN FUND ¤17.46 07/06/2007
ELECTRIC FEE ¤190.20 07/06/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 07/06/2007
STORM WATER PERMIT FEES ¤80.00 07/06/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 07/06/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 07/06/2007
MECHANICAL FEE ¤190.20 07/06/2007
PERMIT FEE ¤1,041.30 07/06/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 07/06/2007
PLAN CHECK FEE ¤106.80 07/06/2007
PLUMBING FEE ¤190.20 07/06/2007
RADON FEE ¤17.46 07/06/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,871.67