I want to search for...
Permit #2007050694
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00360-0070 |
| CONDITIONED SPACE: 2277 sqft |
| GARAGE: 461 sqft |
| OPENED PORCH (WITH ROOF) : 186 sqft |
| OPENED PORCH (WITH ROOF) : 134 sqft |
| Total Square Footage: 3058 sqft |
| Block: 00360 |
| Subdivision: - |
| Job Phone: (386)756-4114 |
| Location Address: 10 LAMOYNE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/12/2007 |
| NOC: RECORDED |
| Applicant name: WAYNE LAWRENCE ADAMS |
| Owner: ADAMS HOMES |
|
Address 3000 GULF BREEZE PARKWAY GULF BREEZE, FL 32563 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤225,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
ADAMS HOMES OF NW FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1101 Gulf Breeze Parkway Suite 229 Gulf Breeze, FL 32561 |
CBC043518 (Exp: 08/31/2014) | (386)254-5081 | (386)252-8284 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
HERSEL L GARDNER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
939 ALEXANDER AVE. DAYTONA BCH, FL 32129 |
CFC033859 (Exp: 08/31/2010) | (386) 761-6049 | (386)767-9972 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/17/2007 | FINAL APPROVED | MMOORE |
| STORMWATER FINAL INSPECTION | 09/14/2007 | APPROVED | GLALIMA |
| Note: 0 road damage | |||
| UTILITY COMPANY FINAL | 09/07/2007 | APPROVED | CBOEHME |
| RESIDENTIAL EARLY POWER | 08/23/2007 | APPROVED | RMARVEL |
| DRIVEWAY | 08/20/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 07/20/2007 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 07/20/2007 | APPROVED | MMOORE |
| ALL ROUGH | 07/18/2007 | APPROVED | MMOORE |
| Note: THERE IS A GROUND INSIDE THE WALL FOR THE ELECTRIC PANEL LEFT AND BELOW THE PANEL AT OUTLET( BLANK )COVER | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/18/2007 | APPROVED | MMOORE |
| Note: 1. THERE IS A GROUND IN THE WALL JUST TO THE LEFT AND BELOW THE ( GARAGE), ELECTRIC PANEL BEHIND A BLANK OUTLET COVER | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 07/12/2007 | APPROVED | CMINI |
| Note: per the request of Jason | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/12/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: per the request of Jason 1)NEED TO ESTABLISH BEARING POINTS ON TRUSSES T07,T08,T09 AT GARAGE.2)NEED REVISION ON CUT TRUSSES BACK WALL.3)TRUSS T15 NEEDS TO HAVE 1/2" BOLTS EVERY 2` PER ENGINEERING.4)NEED STAMPED ENGINEERED POINT LOAD CALCULATION ON HEADERS OF WINDOWS WHERE IT IS WELL OVER 3700 LBS.5)NEED TO REMOVE PLYWOOD REAR PORCH TO SEE ATTACHMENTS AND IF THERE IS ANY DEFICIENCIES IN TRUSSES.6)NEED TO BLOCK FLAT TOP HIP TRUSSES WHERE THEY ARE MORE THAN 24". INCOMPLETE LIST,NOT READY. CHARLIE 931-1251 | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/11/2007 | APPROVED | GLALIMA |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/29/2007 | APPROVED | RMARVEL |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 06/27/2007 | APPROVED | MMOORE |
| TEMPORARY POLE | 06/21/2007 | APPROVED | RMARVEL |
| Note: Steve scheduled inspection |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/10/2007 | 08/10/2007 |
| Note: Released By: WKINELL Received new topo survey/ LGP. | |||
| SW1 | HOLD | 08/09/2007 | 08/09/2007 |
| Note: Held By: WKINELL Received survey states foundation survey, not a topo survey/LGP. The applied correction factor appears to be 0.98 rather than 0.48. Benchmark on received survey makes reference to FFE. Survey that was delivered on 8/9/07 is not acceptable.//wk | |||
| SW1 | HOLD | 07/24/2007 | 07/24/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are lower than expected by an average of 0.48ft. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| ZON | COMPLETE | 06/08/2007 | 06/08/2007 |
| Note: Released By: JGONZALEZ | |||
| BLD | COMPLETE | 06/08/2007 | 06/11/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 05/25/2007 | 05/29/2007 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 05/25/2007 | 05/30/2007 |
| Note: Held By: JGONZALEZ need walkway on site plan need sqft of the lot on site plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 09/17/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 09/17/2007 |
| REINSPECTION FEE | ¤40.00 | 09/17/2007 |
| SW REVISION | ¤40.00 | 09/17/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/12/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/12/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/12/2007 |
| ADMIN FEE | ¤20.00 | 06/12/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/12/2007 |
| BUILDING CODE ADMIN FUND | ¤15.29 | 06/12/2007 |
| ELECTRIC FEE | ¤165.00 | 06/12/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/12/2007 |
| MECHANICAL FEE | ¤165.00 | 06/12/2007 |
| PERMIT FEE | ¤877.50 | 06/12/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/12/2007 |
| PLAN CHECK FEE | ¤90.00 | 06/12/2007 |
| PLUMBING FEE | ¤165.00 | 06/12/2007 |
| RADON FEE | ¤15.29 | 06/12/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,491.13 |