I want to search for...

Permit #2007050694

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00360-0070
CONDITIONED SPACE: 2277 sqft
GARAGE: 461 sqft
OPENED PORCH (WITH ROOF) : 186 sqft
OPENED PORCH (WITH ROOF) : 134 sqft
Total Square Footage: 3058 sqft
Block: 00360
Subdivision: -
Job Phone: (386)756-4114
Location Address: 10 LAMOYNE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/12/2007
NOC: RECORDED
Applicant name: WAYNE LAWRENCE ADAMS
Owner: ADAMS HOMES

Address

3000 GULF BREEZE PARKWAY

GULF BREEZE, FL 32563

Lot: 0070
Contracted Stated Job Value: ¤225,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ADAMS HOMES OF NW FLORIDA INC
Status Location Address State License Number Phone Fax
INACTIVE

1101 Gulf Breeze Parkway Suite 229

Gulf Breeze, FL 32561

CBC043518 (Exp: 08/31/2014) (386)254-5081 (386)252-8284

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
HERSEL L GARDNER
Status Location Address State License Number Phone Fax
CANCEL

939 ALEXANDER AVE.

DAYTONA BCH, FL 32129

CFC033859 (Exp: 08/31/2010) (386) 761-6049 (386)767-9972
MILLARD K KELLER
Status Location Address State License Number Phone Fax
CANCEL

313 S. VOLUSIA AVENUE

DELAND, FL 32724

CCC1325778 (Exp: 08/31/2010) (386) 774-9961 (386)774-2388

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/17/2007 FINAL APPROVED MMOORE
STORMWATER FINAL INSPECTION 09/14/2007 APPROVED GLALIMA
Note: 0 road damage
UTILITY COMPANY FINAL 09/07/2007 APPROVED CBOEHME
RESIDENTIAL EARLY POWER 08/23/2007 APPROVED RMARVEL
DRIVEWAY 08/20/2007 APPROVED DRANDALL
INSULATION INSPECTION 07/20/2007 APPROVED MMOORE
LATH /BRICK FLASHING 07/20/2007 APPROVED MMOORE
ALL ROUGH 07/18/2007 APPROVED MMOORE
Note: THERE IS A GROUND INSIDE THE WALL FOR THE ELECTRIC PANEL LEFT AND BELOW THE PANEL AT OUTLET( BLANK )COVER
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/18/2007 APPROVED MMOORE
Note: 1. THERE IS A GROUND IN THE WALL JUST TO THE LEFT AND BELOW THE ( GARAGE), ELECTRIC PANEL BEHIND A BLANK OUTLET COVER
EXTERIOR WALL SHEATHING/SHEAR WALL 07/12/2007 APPROVED CMINI
Note: per the request of Jason
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/12/2007 Disapproved -FEE REQUIRED CMINI
Note: per the request of Jason 1)NEED TO ESTABLISH BEARING POINTS ON TRUSSES T07,T08,T09 AT GARAGE.2)NEED REVISION ON CUT TRUSSES BACK WALL.3)TRUSS T15 NEEDS TO HAVE 1/2" BOLTS EVERY 2` PER ENGINEERING.4)NEED STAMPED ENGINEERED POINT LOAD CALCULATION ON HEADERS OF WINDOWS WHERE IT IS WELL OVER 3700 LBS.5)NEED TO REMOVE PLYWOOD REAR PORCH TO SEE ATTACHMENTS AND IF THERE IS ANY DEFICIENCIES IN TRUSSES.6)NEED TO BLOCK FLAT TOP HIP TRUSSES WHERE THEY ARE MORE THAN 24". INCOMPLETE LIST,NOT READY. CHARLIE 931-1251
FOUNDATION SURVEY APPROVED BY STORMWATER 07/11/2007 APPROVED GLALIMA
MONOLITHIC SLAB INSPECTION/SLAB 06/29/2007 APPROVED RMARVEL
Note:
FIRST ROUGH PLUMBING INSPECTION 06/27/2007 APPROVED MMOORE
TEMPORARY POLE 06/21/2007 APPROVED RMARVEL
Note: Steve scheduled inspection

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/10/2007 08/10/2007
Note: Released By: WKINELL Received new topo survey/ LGP.
SW1 HOLD 08/09/2007 08/09/2007
Note: Held By: WKINELL Received survey states foundation survey, not a topo survey/LGP. The applied correction factor appears to be 0.98 rather than 0.48. Benchmark on received survey makes reference to FFE. Survey that was delivered on 8/9/07 is not acceptable.//wk
SW1 HOLD 07/24/2007 07/24/2007
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are lower than expected by an average of 0.48ft. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
ZON COMPLETE 06/08/2007 06/08/2007
Note: Released By: JGONZALEZ
BLD COMPLETE 06/08/2007 06/11/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 COMPLETE 05/25/2007 05/29/2007
Note: Released By: WKINELL
ZON HOLD 05/25/2007 05/30/2007
Note: Held By: JGONZALEZ need walkway on site plan need sqft of the lot on site plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 09/17/2007
EARLY POWER INSPECTION ¤40.00 09/17/2007
REINSPECTION FEE ¤40.00 09/17/2007
SW REVISION ¤40.00 09/17/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 06/12/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/12/2007
STORM WATER PERMIT FEES ¤80.00 06/12/2007
ADMIN FEE ¤20.00 06/12/2007
ARC HOUSE REVIEW ¤125.00 06/12/2007
BUILDING CODE ADMIN FUND ¤15.29 06/12/2007
ELECTRIC FEE ¤165.00 06/12/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 06/12/2007
MECHANICAL FEE ¤165.00 06/12/2007
PERMIT FEE ¤877.50 06/12/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 06/12/2007
PLAN CHECK FEE ¤90.00 06/12/2007
PLUMBING FEE ¤165.00 06/12/2007
RADON FEE ¤15.29 06/12/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,491.13