I want to search for...
Permit #2007050788
Permit Details
Status: COED
| Parcel Id: 07-11-31-7012-00140-0180 |
| CONDITIONED SPACE: 2044 sqft |
| GARAGE: 427 sqft |
| OPENED PORCH (WITH ROOF) : 144 sqft |
| OPENED PORCH (WITH ROOF) : 59 sqft |
| Total Square Footage: 2674 sqft |
| Block: 00140 |
| Subdivision: - |
| Job Phone: (386)423-6670 |
| Location Address: 38 BARBERA LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/12/2007 |
| NOC: RECORDED |
| Applicant name: ADAM M BEATY |
| Owner: AFFORDABLE FLORIDA HOMES INC |
|
Address 4070 MONZA DRIVE NEW SMYRNA BEACH, FL 32168 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤197,485.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
AFFORDABLE FLORIDA HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4070 MONZA DRIVE NEW SMYRNA BEACH, FL 32168 |
CRC1328621 (Exp: 09/30/2008) | (386)423-6670 | (866)721-6888 |
Sub Contractors
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 1637 Bunnell, FL 32110 |
ER0011603 (Exp: 08/31/2022) | (386) 437-1537 |
SINCLAIR W STICKLE
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
15 HARGROVE GRADE BLD 2 UNIT G PALM COAST, FL 32137 |
CAC052428 (Exp: 08/31/2018) | 386-446-1114 | (386)446-1278 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GREGORY THOMAS BEATY
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4070 MONZA DRIVE NEW SMYRNA BEACH, FL 32168 |
CCC1326955 (Exp: 08/31/2010) | (386)423-6670 | (866)721-6888 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 01/07/2008 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/19/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: THIS IS A REINSPECTION ATTIC ACCESS DOES NOT APPEAR TO BE FIRE RATED. | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/03/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: 1]MISSING ARC SHEILDS ON KITCHEN AND BATH , 2]MISSING CONNECTOR AT BACK OF A/C DISCONNECT 3] SPA TUB MUST HAVE GFCI BREAKER 4] R807 ATTIC ACCESS NOT TO CODE MARK 931-2912 | |||
| STORMWATER FINAL INSPECTION | 11/27/2007 | APPROVED | DRANDALL |
| Note: no damage 11/28 referred adacent swale work to survey folder/la | |||
| UTILITY COMPANY FINAL | 11/15/2007 | APPROVED | TSCHWEERS |
| Note: Gravity ok. | |||
| RESIDENTIAL EARLY POWER | 11/15/2007 | APPROVED | ACOOPER |
| PRE DRIVEWAY | 10/12/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 09/10/2007 | APPROVED | MMOORE |
| Note: per requset of Adam | |||
| ALL ROUGH | 09/05/2007 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 08/30/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. 3 FRONT WINDOWS WITH ARCHES / TAPCON EACH SIDE AT THE TOPS 2. SEAL DRYER VENT AT OSB | |||
| ALL ROUGH | 08/28/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. NO PRESSURE AT 2ND-ROUGH PLUMBING | |||
| LATH /BRICK FLASHING | 08/28/2007 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/14/2007 | APPROVED | MMOORE |
| Note: requested by contractor | |||
| LINTEL | 07/25/2007 | APPROVED | MMOORE |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/24/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/16/2007 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 07/10/2007 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/07/2007 | 09/07/2007 |
| Note: Released By: WKINELL Received new topo survey/LGP.//wk | |||
| SW1 | HOLD | 08/06/2007 | 08/06/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are low by an average of .29ft. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| ZON | COMPLETE | 06/06/2007 | 06/06/2007 |
| Note: Released By: ECOYNE | |||
| BLD | COMPLETE | 06/06/2007 | 06/07/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | HOLD | 05/31/2007 | 05/31/2007 |
| Note: Held By: ECOYNE cannot locate sq ft calculations on plans | |||
| SW1 | COMPLETE | 06/01/2007 | |
| Note: Released By: LAPTEKAR Driveway appears to 1.5' from CATV riser. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 01/09/2008 |
| REINSPECTION FEE | ¤40.00 | 01/09/2008 |
| REINSPECTION FEE | ¤40.00 | 01/09/2008 |
| REINSPECTION FEE | ¤40.00 | 01/09/2008 |
| REINSPECTION FEE | ¤40.00 | 01/09/2008 |
| SW REVISION | ¤40.00 | 01/09/2008 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/12/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/12/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/12/2007 |
| ADMIN FEE | ¤20.00 | 06/12/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/12/2007 |
| BUILDING CODE ADMIN FUND | ¤13.37 | 06/12/2007 |
| ELECTRIC FEE | ¤148.80 | 06/12/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/12/2007 |
| MECHANICAL FEE | ¤148.80 | 06/12/2007 |
| PERMIT FEE | ¤772.20 | 06/12/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/12/2007 |
| PLAN CHECK FEE | ¤79.20 | 06/12/2007 |
| PLUMBING FEE | ¤148.80 | 06/12/2007 |
| RADON FEE | ¤13.37 | 06/12/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,402.59 |