I want to search for...
Permit #2007060082
Permit Details
Status: CANCEL
| Total Square Footage: 11720 sqft |
| Block: 000A0 |
| Subdivision: 2117 - Town Center Phase 3, BROOKHAVEN |
| Location Address: 105 BROOKHAVEN CT S |
| Type: QP - QUADRAPLEX |
| Issue Date: 08/24/2007 |
| NOC: RECORDED |
| Applicant name: NO CONTRACTOR OF RECORD |
| Owner: SR 100 VEST LLC |
|
Address 6111 PEACHTREE DUNWOODY ROAD ATLANTA, GA 30328 |
|
Address SUITE B-102 ATLANTA, GA 30328 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤1,011,202.00 |
| Job Description: BLDG #30- 4 UNITS-- QUADRAPLEX- SP-MAJ-07-05 |
| Type: CN |
Contractor
NO CONTRACTOR OF RECORD
| Status | State License Number |
| CANCEL | CGC1111111 (Exp: 05/20/2016) |
Sub Contractors
VIRGIL M ADKINS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
10477 NEW KINGS RD JACKSONVILLE, FL 32219 |
EC0000411 (Exp: 08/31/2026) | 904-634-4232 | 904-764-8063 |
JAMES C BOEGGEMAN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4611 107 CIRCLE CLEARWATER, FL 33762 |
CAC018966 (Exp: 08/31/2010) | (727)540-0255 | (727)540-0244 |
STEPHEN JOHN CHASTAIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1923 TAMPA EAST BLVD TAMPA, FL 33619 |
CFC024520 (Exp: 08/31/2012) | (813)246-5341 | (813)246-5345 |
JOHN DARREN CROSBY
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1628-L BROOKSHIRE BVLD. CHARLOTTE, NC 28216 |
CCC057103 (Exp: 08/31/2012) | (704)399-1556 | (704)399-1644 |
Inspection History
| Type | Request Date | Result | Inspector |
| PROJECT STATUS INSPECTION | 07/18/2008 | Disapproved - NO FEE | ACOOPER |
| Note: LENTIL POURED, SITE CLEAN AND NO SAFETY ISSUES NOTED. 113 Brookhaven S Ct and 105 Brookhaven S Ct – Both need to have silt fencing placed along the back of the properties and fix the silt fencing on the front side of the properties. These have dirt yards that are unstable and running off the property so the silt fence needs to be up and maintained properly. - Heather P. Code Officer | |||
| LINTEL | 12/04/2007 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/23/2007 | APPROVED | JHINDMAN |
| FOOTER | 10/23/2007 | APPROVED | JHINDMAN |
| FIRST ROUGH PLUMBING INSPECTION | 09/24/2007 | APPROVED | JGIBSON |
| ELECTRIC FEEDER | 09/24/2007 | APPROVED | RMARVEL |
| TEMPORARY POLE | 08/29/2007 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| TEMPORARY POLE | 08/27/2007 | CANCELLED BY APPLICANT | LHITES |
| LATH /BRICK FLASHING | |||
| SECOND ROUGH PLUMBING INSPECTION | |||
| PROJECT STATUS INSPECTION | |||
| Note: THIS IS A REINSPECTION | |||
| FRAMING | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | |||
| H.V.A.C. ROUGH | |||
| 2ND ROUGH ELECTRICAL | |||
| RESIDENTIAL EARLY POWER | |||
| ELECTRICAL FINAL | |||
| INSULATION INSPECTION | |||
| ROOF IN PROGRESS | |||
| FIREWALL INSPECTION | |||
| FIREWALL INSPECTION 2ND ROUGH | |||
| FIREWALL INSPECTION 3ND ROUGH | |||
| FIREWALL FINAL INSPECTION | |||
| ENGINEERING FINAL | |||
| TRAFFIC ENGINEER | |||
| UTILITY COMMERCIAL FINAL | |||
| UTILITY COMPANY FINAL | |||
| LANDSCAPE FINAL | |||
| FIRE FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/28/2007 | 12/28/2007 |
| Note: Released By: FREODICA Rev.- Electrical - changed lighting at kitchen area. | |||
| BLD | COMPLETE | 11/27/2007 | 11/30/2007 |
| Note: Released By: FREODICA Rev. 1. Changed UL/U356 to 344 at unit separation wall. 2. Dormer/Chimney Detail. | |||
| BLD | COMPLETE | 09/05/2007 | 09/06/2007 |
| Note: Released By: FREODICA Approved for release. Rev.- Revised pantry. | |||
| FD1 | COMPLETE | 08/17/2007 | 08/20/2007 |
| Note: Released By: JPATTEE | |||
| BLD | COMPLETE | 08/03/2007 | 08/20/2007 |
| Note: Released By: CCOTE Approved for Release. | |||
| BLD | HOLD | 06/04/2007 | 06/19/2007 |
| Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2007060082 (102 Brookhaven Ct N) 6/13/07 The following items must be submitted/clarified in order to complete the Building Permit plan review. 1. Sheet A-0.2: General Note items reference outdated and incorrect code references. Revise notes to reference current applicable codes. 2. Sheet A-0.3: The Building Code Analysis/Plumbing Fixture Count/Accessory Building Area are for the Clubhouse & Exercise Room. Revise information to show requirements for this building. 3. Sheets A-7.x: The reinforcing shown for the lintels and bond beam do not match the quantity and placement of steel specified on the structural drawings. 4. Sheet F-1: Provide the UL detail for rated wall UL-U356. 5. Sheet F-1: Specify methods and/or materials for protecting penetrations of rated assemblies. 6. Sheet F-1: Specify that signs or stencils, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS", be applied to all rated wall assemblies, above ceilings and in other concealed spaces, as required. 7. Sheet S1.0: Provide a relief arch detail, where pipes, sleeves and/or conduits pass through footings or foundations. 8. Sheet S1.0: The notes reference a code version that does not exist, outdated and incorrect code references. Revise notes and drawings as required to meet applicable code requirements. 9. Sheet S1.0: The notes indicate that the building is designed as a partially enclosed structure which is not allowed due to the fact that this permit was applied for after the June 1, 2007 date of which all buildings in Palm Coast are required to be designed as enclosed structures. Revise notes and drawings to meet the requirements of an enclosed structure. 10. Sheet S1.0: The CMU/Concrete Beam indicates by asterisk *** states or precast lintel equal. The drawings must indicate as approved by singed and sealed approval by engineer of record or identify specific information for precast lintel to be used as a substitute. 11. Sheet S1.0: Truss Note #15 indicates 2 studs below each girder truss however there is no detail or information as to how the uplift is transferred from the truss to the footing. Provide detail and/or connectors to be used. 12. Sheet S1.0: Provide information as to how blocking is to be attached to masonry structure at perimeter of garage door opening. 13. Sheet S1.1: Detail 3 indicates H2.5 connector with a single top plat. Simpson installation requires nailing of H2.5 into a double top plate. Revise to show a double top plate or provide reduced calculated uplift value for use of a single top plate. 14. Sheet S1.1: Fastening Schedule references a code version that does not exist. Revise to reference current code version. 15. Sheet S1.1: Specify specific connector for truss bearing points at interior bearing wall locations. 16. Sheet S1.1: Specify specific connector for each girder truss connection point. Note 5 on truss connection table stating that connector to be selected based on truss shop drawings which is not acceptable. The engineer of record is responsible for specify specific connectors to be used. 17. Sheet S4.1: The notes indicate CCQ or ECCQ for beam to column connections however there are additional connections that need specification. Provide connectors to be used at outside corner column as well as connector(s) to be used where beams abut a masonry wall. The note regarding straps at corners is unclear since a 4x4 column cannot provide required bearing of 1-1/2" for full width of beams. 18. Sheet M-1.0: There is a handwritten redline note stating N/A above detail 1 and it is not clear what this is for. The detail is generic and does not match floor plans and there is a similar detail on sheet P-1.0 that shows a similar detail but does not include all of the information. Revise details to show actual project conditions and consistent information. 19. Sheet M-1.0: Specify method of anchoring condensing units to resist 120 MPH wind load. 20. The truss layout drawing indicates LVL-D,E at front porches which is not consistent with the structural drawings. Revise this layout or structural drawings to show consistent information. 21. The truss layout/package indicates trusses designed as a partially enclosed structure partially enclosed structure which is not allowed due to the fact that this permit was applied for after the June 1, 2007 date of which all buildings in Palm Coast are required to be designed as enclosed structures. Revise truss submittal to meet the requirements of an enclosed structure. 22. The truss layout drawing contains a note "Structural Engineer is Responsible for Verifying Proper Load On Trusses At Chimney's & Dormers". Provide verification from structural engineer that this has been completed. 23. The floor plan indicates the RA to be through a louvered door, which is partially located in the kitchen and which is less than 10 feet from the range/cook-top which is not allowed. Revise drawings as required to meet code requirements. 24. General Item: Handwritten redline notes on drawings are not acceptable. Submit revised sheets with changes made. 25. General Item: The drawings contain many items and information that is not applicable to this specific project. The drawing sets should be project specific and only contain information for this specific project. 26. Submit revised window, garage door, and door product information as required to show compliance with code requirements for an enclosed structure with impact protected openings. (If plywood panels are to be used there are size limitations and the garage door at a minimum will require a new submittal to show compliance) 27. The energy calculation forms submitted are outdated forms since 12/8/2006. Submit current versions of energy calculation forms. In addition the Owner/Agent line must be signed and dated. ------------------------------------------------------------ Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------------------ | |||
| FD1 | HOLD | 06/18/2007 | |
| Note: Held By: JPATTEE Design submitted plans to comply with current adopted fire codes. ( DO NOT JUST CHANGE THE DATES, COMPLETE DETAILED REVIEW) Plans indicate reviews by County Fire Marshal, this project is not in his jurisdiction. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 11/20/2008 |
| RENEW PERMIT FEES | ¤40.00 | 11/20/2008 |
| REVISION | ¤40.00 | 11/20/2008 |
| REVISION | ¤40.00 | 11/20/2008 |
| SCHOOL BOARD IMPACT FEE MULTI | ¤3,724.00 | 08/24/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/24/2007 |
| 10-06 TRANS IMPACT CONDO/TOWN | ¤7,331.68 | 08/24/2007 |
| ADMIN FEE | ¤20.00 | 08/24/2007 |
| BUILDING CODE ADMIN FUND | ¤58.60 | 08/24/2007 |
| ELECTRIC FEE | ¤636.72 | 08/24/2007 |
| FIRE PLANS REVIEW | ¤117.20 | 08/24/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤740.44 | 08/24/2007 |
| MECHANICAL FEE | ¤636.72 | 08/24/2007 |
| PERMIT FEE | ¤5,561.61 | 08/24/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤4,784.44 | 08/24/2007 |
| PLAN CHECK FEE | ¤1,162.89 | 08/24/2007 |
| PLUMBING FEE | ¤636.72 | 08/24/2007 |
| RADON FEE | ¤58.60 | 08/24/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤25,709.62 |