Permit #2007060082

Permit Details

Status: CANCEL

Total Square Footage: 11720 sqft
Block: 000A0
Subdivision: 2117 - Town Center Phase 3, BROOKHAVEN
Location Address: 105 BROOKHAVEN CT S
Type: QP - QUADRAPLEX
Issue Date: 08/24/2007
NOC: RECORDED
Applicant name: NO CONTRACTOR OF RECORD
Owner: SR 100 VEST LLC

Address

6111 PEACHTREE DUNWOODY ROAD

ATLANTA, GA 30328

Address

SUITE B-102

ATLANTA, GA 30328

Lot: 0010
Contracted Stated Job Value: ¤1,011,202.00
Job Description: BLDG #30- 4 UNITS-- QUADRAPLEX- SP-MAJ-07-05
Type: CN

Contractor

NO CONTRACTOR OF RECORD
Status State License Number
CANCEL CGC1111111 (Exp: 05/20/2016)

Sub Contractors

VIRGIL M ADKINS
Status Location Address State License Number Phone Fax
ACTIVE

10477 NEW KINGS RD

JACKSONVILLE, FL 32219

EC0000411 (Exp: 08/31/2026) 904-634-4232 904-764-8063
JAMES C BOEGGEMAN
Status Location Address State License Number Phone Fax
CANCEL

4611 107 CIRCLE

CLEARWATER, FL 33762

CAC018966 (Exp: 08/31/2010) (727)540-0255 (727)540-0244
STEPHEN JOHN CHASTAIN
Status Location Address State License Number Phone Fax
CANCEL

1923 TAMPA EAST BLVD

TAMPA, FL 33619

CFC024520 (Exp: 08/31/2012) (813)246-5341 (813)246-5345
JOHN DARREN CROSBY
Status Location Address State License Number Phone Fax
CANCEL

1628-L BROOKSHIRE BVLD.

CHARLOTTE, NC 28216

CCC057103 (Exp: 08/31/2012) (704)399-1556 (704)399-1644

Inspection History

Type Request Date Result Inspector
PROJECT STATUS INSPECTION 07/18/2008 Disapproved - NO FEE ACOOPER
Note: LENTIL POURED, SITE CLEAN AND NO SAFETY ISSUES NOTED. 113 Brookhaven S Ct and 105 Brookhaven S Ct – Both need to have silt fencing placed along the back of the properties and fix the silt fencing on the front side of the properties. These have dirt yards that are unstable and running off the property so the silt fence needs to be up and maintained properly. - Heather P. Code Officer
LINTEL 12/04/2007 APPROVED JHINDMAN
MONOLITHIC SLAB INSPECTION/SLAB 10/23/2007 APPROVED JHINDMAN
FOOTER 10/23/2007 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 09/24/2007 APPROVED JGIBSON
ELECTRIC FEEDER 09/24/2007 APPROVED RMARVEL
TEMPORARY POLE 08/29/2007 APPROVED LHITES
Note: THIS IS A REINSPECTION
TEMPORARY POLE 08/27/2007 CANCELLED BY APPLICANT LHITES
LATH /BRICK FLASHING
SECOND ROUGH PLUMBING INSPECTION
PROJECT STATUS INSPECTION
Note: THIS IS A REINSPECTION
FRAMING
ROOF SHEATHING/BRACES/TIES/ DOWN CELL
H.V.A.C. ROUGH
2ND ROUGH ELECTRICAL
RESIDENTIAL EARLY POWER
ELECTRICAL FINAL
INSULATION INSPECTION
ROOF IN PROGRESS
FIREWALL INSPECTION
FIREWALL INSPECTION 2ND ROUGH
FIREWALL INSPECTION 3ND ROUGH
FIREWALL FINAL INSPECTION
ENGINEERING FINAL
TRAFFIC ENGINEER
UTILITY COMMERCIAL FINAL
UTILITY COMPANY FINAL
LANDSCAPE FINAL
FIRE FINAL
FINAL COMPLETE BUILDING INSPECTION

Review History

Department Status Date In Date Out
BLD COMPLETE 12/28/2007 12/28/2007
Note: Released By: FREODICA Rev.- Electrical - changed lighting at kitchen area.
BLD COMPLETE 11/27/2007 11/30/2007
Note: Released By: FREODICA Rev. 1. Changed UL/U356 to 344 at unit separation wall. 2. Dormer/Chimney Detail.
BLD COMPLETE 09/05/2007 09/06/2007
Note: Released By: FREODICA Approved for release. Rev.- Revised pantry.
FD1 COMPLETE 08/17/2007 08/20/2007
Note: Released By: JPATTEE
BLD COMPLETE 08/03/2007 08/20/2007
Note: Released By: CCOTE Approved for Release.
BLD HOLD 06/04/2007 06/19/2007
Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2007060082 (102 Brookhaven Ct N) 6/13/07 The following items must be submitted/clarified in order to complete the Building Permit plan review. 1. Sheet A-0.2: General Note items reference outdated and incorrect code references. Revise notes to reference current applicable codes. 2. Sheet A-0.3: The Building Code Analysis/Plumbing Fixture Count/Accessory Building Area are for the Clubhouse & Exercise Room. Revise information to show requirements for this building. 3. Sheets A-7.x: The reinforcing shown for the lintels and bond beam do not match the quantity and placement of steel specified on the structural drawings. 4. Sheet F-1: Provide the UL detail for rated wall UL-U356. 5. Sheet F-1: Specify methods and/or materials for protecting penetrations of rated assemblies. 6. Sheet F-1: Specify that signs or stencils, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS", be applied to all rated wall assemblies, above ceilings and in other concealed spaces, as required. 7. Sheet S1.0: Provide a relief arch detail, where pipes, sleeves and/or conduits pass through footings or foundations. 8. Sheet S1.0: The notes reference a code version that does not exist, outdated and incorrect code references. Revise notes and drawings as required to meet applicable code requirements. 9. Sheet S1.0: The notes indicate that the building is designed as a partially enclosed structure which is not allowed due to the fact that this permit was applied for after the June 1, 2007 date of which all buildings in Palm Coast are required to be designed as enclosed structures. Revise notes and drawings to meet the requirements of an enclosed structure. 10. Sheet S1.0: The CMU/Concrete Beam indicates by asterisk *** states or precast lintel equal. The drawings must indicate as approved by singed and sealed approval by engineer of record or identify specific information for precast lintel to be used as a substitute. 11. Sheet S1.0: Truss Note #15 indicates 2 studs below each girder truss however there is no detail or information as to how the uplift is transferred from the truss to the footing. Provide detail and/or connectors to be used. 12. Sheet S1.0: Provide information as to how blocking is to be attached to masonry structure at perimeter of garage door opening. 13. Sheet S1.1: Detail 3 indicates H2.5 connector with a single top plat. Simpson installation requires nailing of H2.5 into a double top plate. Revise to show a double top plate or provide reduced calculated uplift value for use of a single top plate. 14. Sheet S1.1: Fastening Schedule references a code version that does not exist. Revise to reference current code version. 15. Sheet S1.1: Specify specific connector for truss bearing points at interior bearing wall locations. 16. Sheet S1.1: Specify specific connector for each girder truss connection point. Note 5 on truss connection table stating that connector to be selected based on truss shop drawings which is not acceptable. The engineer of record is responsible for specify specific connectors to be used. 17. Sheet S4.1: The notes indicate CCQ or ECCQ for beam to column connections however there are additional connections that need specification. Provide connectors to be used at outside corner column as well as connector(s) to be used where beams abut a masonry wall. The note regarding straps at corners is unclear since a 4x4 column cannot provide required bearing of 1-1/2" for full width of beams. 18. Sheet M-1.0: There is a handwritten redline note stating N/A above detail 1 and it is not clear what this is for. The detail is generic and does not match floor plans and there is a similar detail on sheet P-1.0 that shows a similar detail but does not include all of the information. Revise details to show actual project conditions and consistent information. 19. Sheet M-1.0: Specify method of anchoring condensing units to resist 120 MPH wind load. 20. The truss layout drawing indicates LVL-D,E at front porches which is not consistent with the structural drawings. Revise this layout or structural drawings to show consistent information. 21. The truss layout/package indicates trusses designed as a partially enclosed structure partially enclosed structure which is not allowed due to the fact that this permit was applied for after the June 1, 2007 date of which all buildings in Palm Coast are required to be designed as enclosed structures. Revise truss submittal to meet the requirements of an enclosed structure. 22. The truss layout drawing contains a note "Structural Engineer is Responsible for Verifying Proper Load On Trusses At Chimney's & Dormers". Provide verification from structural engineer that this has been completed. 23. The floor plan indicates the RA to be through a louvered door, which is partially located in the kitchen and which is less than 10 feet from the range/cook-top which is not allowed. Revise drawings as required to meet code requirements. 24. General Item: Handwritten redline notes on drawings are not acceptable. Submit revised sheets with changes made. 25. General Item: The drawings contain many items and information that is not applicable to this specific project. The drawing sets should be project specific and only contain information for this specific project. 26. Submit revised window, garage door, and door product information as required to show compliance with code requirements for an enclosed structure with impact protected openings. (If plywood panels are to be used there are size limitations and the garage door at a minimum will require a new submittal to show compliance) 27. The energy calculation forms submitted are outdated forms since 12/8/2006. Submit current versions of energy calculation forms. In addition the Owner/Agent line must be signed and dated. ------------------------------------------------------------ Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------------------
FD1 HOLD 06/18/2007
Note: Held By: JPATTEE Design submitted plans to comply with current adopted fire codes. ( DO NOT JUST CHANGE THE DATES, COMPLETE DETAILED REVIEW) Plans indicate reviews by County Fire Marshal, this project is not in his jurisdiction.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 11/20/2008
RENEW PERMIT FEES ¤40.00 11/20/2008
REVISION ¤40.00 11/20/2008
REVISION ¤40.00 11/20/2008
SCHOOL BOARD IMPACT FEE MULTI ¤3,724.00 08/24/2007
STORM WATER PERMIT FEES ¤80.00 08/24/2007
10-06 TRANS IMPACT CONDO/TOWN ¤7,331.68 08/24/2007
ADMIN FEE ¤20.00 08/24/2007
BUILDING CODE ADMIN FUND ¤58.60 08/24/2007
ELECTRIC FEE ¤636.72 08/24/2007
FIRE PLANS REVIEW ¤117.20 08/24/2007
FIRE IMPACT FEE RES 4/1/07 ¤740.44 08/24/2007
MECHANICAL FEE ¤636.72 08/24/2007
PERMIT FEE ¤5,561.61 08/24/2007
PARKS IMPACT FEE 4/1/07 ¤4,784.44 08/24/2007
PLAN CHECK FEE ¤1,162.89 08/24/2007
PLUMBING FEE ¤636.72 08/24/2007
RADON FEE ¤58.60 08/24/2007
Fees Total Due: ¤0.00 Total Paid: ¤25,709.62