I want to search for...

Permit #2007060113

Permit Details

Status: COED

Parcel Id: 07-11-31-7064-00130-0130
CONDITIONED SPACE: 2170 sqft
GARAGE: 468 sqft
OPENED PORCH (WITH ROOF) : 401 sqft
OPENED PORCH (WITH ROOF) : 135 sqft
Total Square Footage: 3174 sqft
Block: 00130
Subdivision: -
Job Phone: (386) 445-7945
Location Address: 6 LLANES PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/02/2007
NOC: RECORDED
Applicant name: RYSZARD A SKLADZIEN
Owner: SKRODZKI JOZEF & ALICJA

Address

39-60 54TH STREET #8X

WOODSIDE, NY 11377

Lot: 0130
Contracted Stated Job Value: ¤230,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

RYSKCON CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
CANCEL

2 Market Place Unit D

Palm Coast, FL 32137

CGC037470 (Exp: 08/31/2014) (386) 445-7945 (386)446-3871

Sub Contractors

RONALD E BANKS
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353741

PALM COAST, FL 32164

CAC049308 (Exp: 08/31/2010) (386) 437-4800 (386)445-0030
BRUCE EDWARD HAWKESWORTH
Status Location Address State License Number Phone
CANCEL

671 Dara Circle

DELTONA, FL 32735

CFC053329 (Exp: 09/30/2008) (386) 228-2784
RYSZARD ALOJZY SKLADZIEN
Status Location Address State License Number Phone Fax
CANCEL

2 MARKET PLACE UNIT D

PALM COAST, FL 32137

CCC057546 (Exp: 08/31/2016) (386)445-7945 (386)446-3871
HENRY PICKETT
Status Location Address Mailing Address State License Number
INACTIVE

4850 COLLINS ROAD

ORANGE PARK, FL 32073

# 105

ORANGE PARK, FL 32073

EC0001112 (Exp: 08/31/2022)

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/25/2008 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION ( per request of Caezar). 1 of 1: WINDOWS AND DOORS MUST BE EQUIPPED WITH STORM PROTECTION AS SPECIFIED ON THE PLANS. Requested by contractor
FINAL COMPLETE BUILDING INSPECTION 04/16/2008 Disapproved -FEE REQUIRED PGALLMANN
Note: THIS IS A REINSPECTION ( per request of Caezar). 1 of 1: WINDOWS AND DOORS MUST BE EQUIPPED WITH STORM PROTECTION AS SPECIFIED ON THE PLANS.
FINAL COMPLETE BUILDING INSPECTION 04/08/2008 Disapproved -FEE REQUIRED JGIBSON
Note: All window and door openings to be protected by Fabric Sheild Hurricane Protection. MISSING NUMBERS ON HOUSE, MISSING BUSHING OR CONNECTOR @ A/C CONDENCING UNIT, NEED TO ANCHOR LAUNDRY TUB TO FLOOR IN GARAGE AND INSTALL VACUME BREAKER @ SPOUT, BREAKER 23 IN PANEL ARC FAULT NOT RESETTING, PROVIDE ACCESS PANEL FOR MASTER BATH TUB MOTOR, PROVIDE BULBS IN ALL EXTERIOR LIGHTS FOR EGRESS, IF INSTALLING BACK-SPLASH IN KIT NEED IN FOR FINAL INSPECTION AS WELL AS ATTIC LADDER STAIRS..........MARK 931-2912
STORMWATER FINAL INSPECTION 04/07/2008 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 03/24/2008 APPROVED BPARRESOL
STORMWATER FINAL INSPECTION 03/24/2008 Disapproved -FEE REQUIRED DRANDALL
Note: 1. 24 sq ft road damage 2. remove tree barricades from rear....remove fallen pine trees stacked from lot clearing 3. regrade rear property line to a 2:1 slope ending at property line 4. seed and straw all exposed earth on rear adjacent property
RESIDENTIAL EARLY POWER 02/13/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION per contractor request
RESIDENTIAL EARLY POWER 02/05/2008 Disapproved -FEE REQUIRED RMARVEL
Note: requested by contractor DAMAGED NM CABLE WHERE DRYWALL IS CUT OUT IN KITCHEN. ALSO COUNTER TOP RECEPTACLE SPACING IS NOT TO CODE.
PRE DRIVEWAY 10/17/2007 APPROVED GLALIMA
ALL ROUGH 10/15/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 10/11/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION HALL BATH EXHAUST FAN NOT DUCTED TO OUTSIDE/NAIL GUARD FOR VENT STACK AT SHOE PLATE MASTER BATH/
INSULATION INSPECTION 10/11/2007 APPROVED DROCKWELL
ALL ROUGH 10/04/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: THIS IS A REINSPECTION... 1) THE OFFSET IN THE CHIMNEY IS NOT INSTALLED PER THE INSTALLATION INSTRUCTIONS. PER INSTRUCTIONS, WHEN AN OFFSET IS INSTALLED IT MUST HAVE ADDITIONAL SUPPORT. THIS CAN BE ACHIEVED BY USING A "STABILIZER" (PAGE13 FIGURE 36) OR A "RETURN ELBOW" (PAGE 14 FIGURE 41). 2) THE COMBUSTION AIR INTAKE IS RAN INTO THE ATTIC, RESTING (NOT FASTENED) ON TOP OF AN EXTERIOR WALL. PROVIDE THE "DETAILED INSTALLATION INSTRUCTIONS" FOR THE COMBUSTION AIR KIT, AS NOTED IN PAGE 15.
ALL ROUGH 10/01/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: NEED 4`` CLEARANCE AROUND A/C DROPS IN GARAGE CEILING/WIRE AT KITCHEN FLOOR NEEDS 6`` SLEEVE/FILL VOID UNDER TOILET FLANGE WITH APPROPRIATE MATERIAL/FIRE BLOCKING MISSING ALONG WITH PIPE PROTECTION BAY WINDOW AREA IN KITCHEN OUTSIDE WALL.
LATH /BRICK FLASHING 09/27/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/27/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 09/21/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: MUST FIRST HAVE SHEATHING APPROVED BECAUSE AREA IN QUESTION IS LATHED.SEE PREVIOUS INSPECTION.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/11/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION SHOW APPROVED ENGINEERING AT KITCHEN BAY FRAMING.AS BUILT HAS FRAMING SUPPORTED BY TRUSSES.NEED APPROVAL OF TRUSS ENGINEER.PLANS PROVIDED HAS NO DETAIL OF THIS AREA.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/05/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: THIS IS A REINSPECTION 1) STUDS UNDER TRUSSES @ LEFT WALL IN GARAGE ARE MORE THAN 5" AWAY FROM TRUSS BEARING POINT. 2) UPLIFT STRAPS MISSING FROM TRUSSES @ OCTAGON/ENTRY TIEBEAM. NOTE TO NEXT INSPECTOR: INCOMPLETE INSPECTION DUE TO VISIBILITY. A/C CREWS INSTALLING FLEX DUCT AT TIME OF INSPECTION.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/29/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: Truss engineering not in box/Structural framing not completed/Incomplete inspection
EXTERIOR WALL SHEATHING/SHEAR WALL 08/27/2007 APPROVED DROCKWELL
LINTEL 08/06/2007 APPROVED PGALLMANN
FOUNDATION SURVEY APPROVED BY STORMWATER 08/02/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 07/25/2007 APPROVED PGALLMANN
FIRST ROUGH PLUMBING INSPECTION 07/23/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 07/20/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: Requested by contractor NEED PLANS APPROVED BY CITY.

Review History

Department Status Date In Date Out
BLD COMPLETE 09/21/2007 09/26/2007
Note: Released By: FREODICA Rev- Mitered glass detail and truss repair- T3T REP, T1 REP, T1A REP
BLD COMPLETE 06/20/2007 06/21/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 06/19/2007 06/20/2007
Note: Held By: JJOSEPH 1.Provide Florida Product Approval Number and manual installation.
BLD HOLD 06/14/2007 06/14/2007
Note: Held By: JJOSEPH How the openings will be protected ( such as mitered glass , windows etc..)? Your windows are they impact resistant? If yes give a proof otherwise provide protections.
ZON COMPLETE 06/12/2007 06/12/2007
Note: Released By: ECOYNE
BLD HOLD 06/12/2007 06/13/2007
Note: Held By: JJOSEPH 1.Provide protection of opennings and enclosed structure.(Ref Florida Building Code 2007 Supplement) 2. The sheet 1 of 5 (Elevation plans) is missing for one copy of plans.
SW1 COMPLETE 06/05/2007 06/06/2007
Note: Released By: WKINELL
ZON HOLD 06/05/2007 06/07/2007
Note: Held By: ECOYNE need sealed survey

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 04/25/2008
EARLY POWER INSPECTION ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REINSPECTION FEE ¤40.00 04/25/2008
REVISION ¤40.00 04/25/2008
ADDITIONAL FEE ¤40.00 04/25/2008
STORMWATER REINSPECTION FEE ¤35.00 04/25/2008
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 07/02/2007
ADMIN FEE ¤20.00 07/02/2007
ARC HOUSE REVIEW ¤125.00 07/02/2007
BUILDING CODE ADMIN FUND ¤15.87 07/02/2007
ELECTRIC FEE ¤168.00 07/02/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 07/02/2007
STORM WATER PERMIT FEES ¤80.00 07/02/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 07/02/2007
MECHANICAL FEE ¤168.00 07/02/2007
PERMIT FEE ¤897.00 07/02/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 07/02/2007
PLAN CHECK FEE ¤92.00 07/02/2007
PLUMBING FEE ¤168.00 07/02/2007
RADON FEE ¤15.87 07/02/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,997.79