Permit #2007060135
Permit Details
Status: COED
| Parcel Id: 07-11-31-7001-000A0-0090 |
| Total Square Footage: 1563 sqft |
| Block: 00A0 |
| Subdivision: - |
| Job Phone: (386) 445-7945 |
| Location Address: 9 HARBOR CENTER DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 08/23/2007 |
| NOC: RECORDED |
| Applicant name: RYSZARD A SKLADZIEN |
| Owner: PALM HARBOR BBQ & GRILL |
|
Address A FLORIDA CORP PALM COAST, FL 32137 |
|
Address 58 FARISTON PLACE PALM COAST, FL 32137 |
| Lot: 9 |
| Contracted Stated Job Value: ¤40,000.00 |
| Job Description: A BBQ TAKE OUT RESTAURANT-- UNIT A -- SUITE 11 |
| Type: CN |
Contractor
RYSKCON CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 Market Place Unit D Palm Coast, FL 32137 |
CGC037470 (Exp: 08/31/2014) | (386) 445-7945 | (386)446-3871 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
THOMAS ALAN MOSE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1894 HOLLY HILL, FL 32117 |
CAC048082 (Exp: 08/31/2026) | 386-255-4545 | (386)252-4979 |
BOB BELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
20 UTILITY DRIVE PALM COAST, FL 32137 |
13878 (Exp: 08/31/2012) | (386)437-4404 | (386)446-2191 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 11/02/2007 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION per placard card | |||
| FINAL COMPLETE BUILDING INSPECTION | 11/01/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: ANCHOR DOWN CONDENSOR UNIT. INSTALL WATER HAMMER ARRESTOR ON ICE MACHINE. FRONT EXIT LIGHT NOT WORKING. | |||
| FIRE FINAL | 10/31/2007 | APPROVED - AS NOTED | JPATTEE |
| Note: Fix exit light front door | |||
| ELECTRICAL FINAL | 10/30/2007 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION CANNOT FINAL DUE TO OTHER INSPECTIONS. | |||
| ELECTRICAL FINAL | 10/29/2007 | Disapproved -FEE REQUIRED | LHITES |
| Note: OULET ON TOP OF COOLER CANNOT FACE UP, MENS BATH GFI HOT AND NEUTRAL ARE CROSSED, REPLACE OUTLET THAT IS FULL OF CAULK, OULET BHIND COUNTER MUST BE SINGLE OR GFI PROTECTED | |||
| UTILITY COMMERCIAL FINAL | 10/24/2007 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 10/24/2007 | APPROVED | TSCHWEERS |
| Note: Gravity ok, no permit to sign. | |||
| GAS FINAL | 10/19/2007 | APPROVED | JLEVRAULT |
| ABOVE CEILING | 10/19/2007 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ABOVE CEILING | 10/17/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: DUCTWORK FOR HOOD NOT COMPLETED ABOVE CEILING. | |||
| FRAMING | 10/16/2007 | CANCELLED BY INSPECTOR | JLEVRAULT |
| Note: THIS WAS ALREADY PREVIOUSLY APPROVED. MISTAKINGLY RECALLED BY OWNER. | |||
| H.V.A.C. ROUGH | 10/16/2007 | APPROVED | JLEVRAULT |
| ALL ROUGH | 10/05/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: PLUMBING AND MECHANICAL. FRAMING WAS APPROVED LAST WEEK AND ELECTRICAL WAS PREVIOUSLY APPROVED FOR WALLS ONLY. | |||
| FRAMING | 09/28/2007 | APPROVED | JLEVRAULT |
| 2ND ROUGH ELECTRICAL | 09/27/2007 | APPROVED | LHITES |
| Note: WALLS ONLY | |||
| GAS ROUGH | 09/27/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED REVISION TO SHOW DELITION OF 200,000 BTU GRILL. PER PLAN | |||
| SECOND ROUGH PLUMBING INSPECTION | 09/18/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: INSTALL VENT FOR GREASE INTERCEPTOR | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 09/11/2007 | APPROVED | JLEVRAULT |
| FIRST ROUGH PLUMBING INSPECTION | 09/10/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS IS A REINSPECTION THIS WAS FOR INSPECTION OF REVISION ON GREASE LINE ADDED TO SANITARY SYSTEM. | |||
| FIRST ROUGH PLUMBING INSPECTION | 08/29/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: PLUMBING NOT DONE TO PLAN - SUBMIT REVISION. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/17/2007 | 10/19/2007 |
| Note: Released By: FREODICA Rev.- Cap/plug gas line leading to grille for future use. | |||
| BLD | HOLD | 09/06/2007 | 09/06/2007 |
| Note: Held By: FREODICA 1. Revise the New Plumbing layout and sanitary riser diagram. The sanitary line shall not be tied-in together with the grease line before going to the grease trap. Grease line shall be tied-in to sanitary only after the grease trap. | |||
| BLD | COMPLETE | 08/31/2007 | 09/07/2007 |
| Note: Released By: FREODICA Approved for release. Rev.- Revised sanitary layout and riser diagram. | |||
| BLD | COMPLETE | 08/22/2007 | 08/23/2007 |
| Note: Released By: CCOTE Approved for Release per plan notes. Review by Fred R. | |||
| ZON | COMPLETE | 08/14/2007 | 08/15/2007 |
| Note: Released By: JGONZALEZ modification brought in to add propane gas to building Need survey showing location of tank with setbacks for above ground tanks must also show location of fence around tank Need color and material sheet giving type, height and color fence around tank | |||
| BLD | HOLD | 08/13/2007 | 08/14/2007 |
| Note: Held By: FREODICA In order to process the permit application, the following previous comments shall be addressed completely: " Provide a mechanical plan, which shows new duct lay out and sizing, existing supply and return air grill locations, new and existing AHU installation detail and location, new and existing fresh air intake locations and new and existing exhaust fan termination points. - Submitted duct layout does not show fresh air intake and return air duct from the seating area. There is only one return air located in the kitchen area which is not allowed by code. Revise duct layout. Also provide calculations showing the minimum outside air required by code. " Provide electrical load calculations. - Provide name and license No. of person doing the calculations and delete water heater load as the plan shows gas heater. " Provide electrical panel schedule. " Provide or verify existing switched light(s) outside the kitchen and waiting area exits. " Provide installation detail(s) for the water heater. If the water heater is electric revise the gas riser diagram, if the water heater is gas revise the energy calculations. - Provide gas riser diagram showing the material, pipe size, lenght, required BTUs of each equipment, delivery pressure from tank to regurator, and pressure drop. | |||
| BLD | HOLD | 07/23/2007 | 08/02/2007 |
| Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Clarify; the store front window and door lay out, is not the same on the floor plan as it is on the life safety and plumbing plan. " If the store front is to be remodeled, provide details of that work. " Clarify; the floor plan indicates the two required H.C. accessible restrooms, the life safety plan and the plumbing plan, each show only one. " Provide a seating layout. " Provide at least two H.C. accessible seating positions. " Specify door hardware which complies with FBC 11-4.13.9 H.C. accessibility. " Clarify; door # 2, between the sitting area and the waiting area is shown on the floor plan as a 3068 and shown on the door schedule as a 3070. " Provide framing detail for the installation of door # 2, between the sitting area and the waiting area. The floor plan shows this to be a full height door to be installed in a 5' high knee wall. " Clarify; floor plan indicates a new ac condensing unit and an existing ac/cu but notes on sheet 1of 2 indicates existing AHU in attic and existing mechanical system in place. " Provide a mechanical plan, which shows new duct lay out and sizing, existing supply and return air grill locations, new and existing AHU installation detail and location, new and existing fresh air intake locations and new and existing exhaust fan termination points. " Provide electrical load calculations. " Provide electrical meter riser diagram, including location, conduit sizes, conductor sizes and conductor type. " Provide electrical panel schedule. " Verify that required working clearance(s) around the panel will be maintained. " Provide GFCI protection for receptacle outlet in restrooms. " Provide receptacle outlets for show windows, at least one receptacle outlet for 12 linear feet or portion there of, of window. " Provide or verify existing switched light(s) outside the kitchen and waiting area exits. " Clarify the location of the exit light at the primary exit from the sitting area. " Clarify; the sanitary sewer riser diagram indicates two mop sinks, the floor plan shows only one. " Revise sanitary sewer riser diagram to include both restrooms. " Revise the grease system riser diagram to include the floor drain located in front of the 3 compartment sink. " Revise water riser diagram to include both restrooms and the water nozzle near the coffee/soda machine. " Clarify; the floor plan indicates a ceiling mounted tank less water heater, the gas riser plan indicates a 199,000 BTU water heater, the energy calculations indicate an electric water heater. " Provide installation detail(s) for the water heater. If the water heater is electric revise the gas riser diagram, if the water heater is gas revise the energy calculations. " Indicate the location of the two proposed LP gas cylinders Larry Woodrome, CBO Building Official City of Palm Coast 386-986-3786 | |||
| FI1 | COMPLETE | 07/18/2007 | 07/23/2007 |
| Note: Released By: JPATTEE Automatic fire sprinkler heads shall be required in cooler and freezer. | |||
| UD1 | COMPLETE | 07/13/2007 | 07/16/2007 |
| Note: Released By: CJOHNSON | |||
| UD1 | HOLD | 07/10/2007 | 07/11/2007 |
| Note: Held By: CJOHNSON | |||
| ZON | COMPLETE | 06/29/2007 | 06/29/2007 |
| Note: Released By: ECOYNE | |||
| ZON | HOLD | 06/07/2007 | 06/22/2007 |
| Note: Held By: ECOYNE spoke with Constance - need to reduce seating area spoke with Chris/Utilities - no units have grease interceptor called contractor - need to reduce seating area by 50 sq ft. | |||
| ZON | HOLD | 06/05/2007 | 06/06/2007 |
| Note: Held By: ECOYNE Need sq footage of seating area need number of parkings spaces dedicated to the restaurant Need number of employees per shift received information need 13.92 spaces further info on adjoining businesses if there is adequate parking 06/12/07 LEFT MESSAGE NEED ORIGINAL SITE PLANS SHOWING PARKING PLACES ALLOWED FOR LOT 9 | |||
| ZON | HOLD | 06/26/2007 | |
| Note: Held By: ECOYNE Received revised site plan - need sealed plans (first page of plan must be changed out. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 11/02/2007 |
| REINSPECTION FEE | ¤40.00 | 11/02/2007 |
| REINSPECTION FEE | ¤40.00 | 11/02/2007 |
| REINSPECTION FEE | ¤40.00 | 11/02/2007 |
| REVISION | ¤40.00 | 11/02/2007 |
| REVISION | ¤40.00 | 11/02/2007 |
| ADDITIONAL FEE | ¤40.00 | 08/28/2007 |
| ADMIN FEE | ¤20.00 | 08/23/2007 |
| ELECTRIC FEE | ¤54.00 | 08/23/2007 |
| FIRE PLANS REVIEW | ¤25.00 | 08/23/2007 |
| MECHANICAL FEE | ¤54.00 | 08/23/2007 |
| PERMIT FEE | ¤280.00 | 08/23/2007 |
| PLAN CHECK FEE | ¤100.00 | 08/23/2007 |
| PLUMBING FEE | ¤54.00 | 08/23/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤867.00 |