I want to search for...
Permit #2007060205
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00880-0080 |
| CONDITIONED SPACE: 2596 sqft |
| GARAGE: 512 sqft |
| OPENED PORCH (WITH ROOF) : 201 sqft |
| OPENED PORCH (WITH ROOF) : 76 sqft |
| Total Square Footage: 3385 sqft |
| Block: 00880 |
| Subdivision: - |
| Job Phone: (908)872-1605 |
| Location Address: 70 ETHAN ALLEN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/19/2007 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: WRIGHT, JOSEPH E & TONYA |
|
Address 7 WESTBRIAR PLACE PALM COAST, FL 32164 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤287,725.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Sub Contractors
JEFFREY EUGENE COOK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
240 BARCO ROAD ST AUGUSTINE, FL 32086 |
EC13002583 (Exp: 08/31/2026) | 904-424-2491 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
JOSE ANTONIO PILLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
35 E. DIAMOND DRIVE PALM COAST, FL 32164 |
CCC1326043 (Exp: 08/31/2010) | (386)586-4969 | (386)239-9794 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/15/2008 | FINAL APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 02/14/2008 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: ALL OUTLETS AND SWITCHES IN-MASTER BEDROOM NOT ON ARC FAULT BREAKERS, A/C DISCONNECT MISSING BUSHING AND BOX DEFECTIVE REPLACE AND CALL BACK IN EVERYTHING ELSE IS IN WITH COMPLIANCE OF BUILDING CODE..........MARK 931-2912 | |||
| STORMWATER FINAL INSPECTION | 02/05/2008 | APPROVED | GLALIMA |
| UTILITY COMPANY FINAL | 02/05/2008 | APPROVED | MBACON |
| PRE DRIVEWAY | 01/15/2008 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 01/08/2008 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SPOKE WITH BUILDER '' AND HE NEEDED TO CALL THE OTHER INSPECTOR , FAILED '' IF NEEDED CALL GARY LALIMA AT 931-0208 . | |||
| RESIDENTIAL EARLY POWER | 12/18/2007 | APPROVED | JHINDMAN |
| INSULATION INSPECTION | 10/15/2007 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 10/12/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: DRAFTSTOPPING AT SERVICE PANEL IN CEILING INCOMPLETE | |||
| ALL ROUGH | 09/18/2007 | APPROVED | PGALLMANN |
| LATH /BRICK FLASHING | 09/17/2007 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/14/2007 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/12/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: PLANS SHOW 2-2X12 HEADER OVER ENTRY DOOR/T-43 + T-42 OSB NEEDS BLOCKING/BEAM POURED TOO LOW AT MID-POINT BEARING/FASTEN LOOSE STRAP AT ABOVE ROOF FRAMING/NO TRUSS ENGINEERING ON JOB. | |||
| LINTEL | 08/08/2007 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 08/07/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: MISSING MANY DOWELS DRILLING BEING DONE @ TIME OF INSPECTION CHECK ALL BOND BEAM STEEL FOR BEING TIED | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 08/03/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/26/2007 | APPROVED | PGALLMANN |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/25/2007 | CANCELLED BY INSPECTOR | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 07/24/2007 | APPROVED | PGALLMANN |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/23/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: CALLED BY CONTRACTOR WATER LINES THRU FOOTER MUST BE SLEEVED W/PIPE 21/2 X LARGER | |||
| FIRST ROUGH PLUMBING INSPECTION | 07/18/2007 | APPROVED | PGALLMANN |
| TEMPORARY POLE | 07/18/2007 | APPROVED | LHITES |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 01/11/2008 | 01/11/2008 |
| Note: Released By: LAPTEKAR Changing driveway to 2 3/8" pavers///in ROW concrete base will be used | |||
| BLD | COMPLETE | 09/14/2007 | 09/18/2007 |
| Note: Released By: FREODICA Rev. - glass miter detail. | |||
| BLD | COMPLETE | 06/14/2007 | 06/18/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 06/14/2007 | 06/14/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 06/08/2007 | 06/13/2007 |
| Note: Held By: JGONZALEZ need sealed survey showing lot size, flood information, and all easements need landscaping plan and one additional tree | |||
| SW1 | COMPLETE | 06/11/2007 | |
| Note: Released By: WKINELL Must institute erosion control measures along rear property line to protect Ditch.//wk |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 02/15/2008 |
| REINSPECTION FEE | ¤40.00 | 02/15/2008 |
| REINSPECTION FEE | ¤40.00 | 02/15/2008 |
| REINSPECTION FEE | ¤40.00 | 02/15/2008 |
| REINSPECTION FEE | ¤40.00 | 02/15/2008 |
| REINSPECTION FEE | ¤40.00 | 02/15/2008 |
| REINSPECTION FEE | ¤40.00 | 02/15/2008 |
| REVISION | ¤40.00 | 02/15/2008 |
| ADDITIONAL FEE | ¤40.00 | 02/15/2008 |
| ADDITIONAL FEE | ¤40.00 | 02/15/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/15/2008 |
| SW REVISION | ¤40.00 | 02/15/2008 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 06/19/2007 |
| ADMIN FEE | ¤20.00 | 06/19/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 06/19/2007 |
| BUILDING CODE ADMIN FUND | ¤16.93 | 06/19/2007 |
| ELECTRIC FEE | ¤202.80 | 06/19/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/19/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/19/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 06/19/2007 |
| MECHANICAL FEE | ¤202.80 | 06/19/2007 |
| PERMIT FEE | ¤1,123.20 | 06/19/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 06/19/2007 |
| PLAN CHECK FEE | ¤115.20 | 06/19/2007 |
| PLUMBING FEE | ¤202.80 | 06/19/2007 |
| RADON FEE | ¤16.93 | 06/19/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,193.71 |