Status: FINAL
| Parcel Id: 07-11-31-7024-00010-0310 |
| CONDITIONED SPACE: 984 sqft |
| PATIO/DECK (NO ROOF) : 672 sqft |
| Total Square Footage: 1656 sqft |
| Block: 00010 |
| Subdivision: - |
| Job Phone: (386) 547-0409 |
| Location Address: 28 PRINCESS RUTH LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 07/13/2007 |
| NOC: RECORDED |
| Applicant name: BOHDAN HAWRYLUK |
| Owner: SKINNER, DAVID & DENISE |
|
Address 28 PRINCESS RUTH LANE PALM COAST, FL 32164 |
| Lot: 0310 |
| Contracted Stated Job Value: ¤31,500.00 |
| Job Description: ADDITION & CONCRETE PATIO SLAB |
| Type: CN |
Contractor
INTERCOASTAL CONSTRUCTION CO.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
Sub Contractors
KEITH ALLEN MCCALL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
505 FINCH DRIVE EDGEWATER, FL 32132 |
EC13003555 (Exp: 09/30/2008) | (386)427-8920 | (386)427-8920 |
EDDIE T PALMATEER
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
2985 ENTERPRISE ROAD DEBARY, FL 32713 |
SUITE A DEBARY, FL 32713 |
CAC1813533 (Exp: 08/31/2024) | (386)668-8651 | (386)668-7758 |
ROBERT H L'AMIE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 730625 ORMOND BEACH, FL 32173 |
CFC029741 (Exp: 08/31/2014) | (386)527-1646 | (386)527-1646 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL INSPECTION (MISC) | 02/08/2008 | FINAL APPROVED | JGIBSON |
| Note: requested by contractor | |||
| STORMWATER FINAL INSPECTION | 02/05/2008 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: already passed inspection 1/18/08 | |||
| STORMWATER FINAL INSPECTION | 01/17/2008 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 01/11/2008 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 01/11/2008 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: pine needles are down, i don 't see any grass seed.....seed all exposed earth on left adj. property ,access to work area | |||
| LINTEL | 09/25/2007 | APPROVED | PGALLMANN |
| INSULATION INSPECTION | 09/14/2007 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 09/13/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO USE FIRE RATED FOAM OR CAULK AT ALL PENETRATIONS OF TOP PLATES......ALUMINUM FOIL IS NOT A CORRECT MEANS OF WIRE STRAPPING NEED TO USE APPROVED METHED BY REMOVING TAPE AND ADDING STRAPS...SEAL AROUND SWITCH BOX WHERE BLOCK IS KNOCKED OUT THAT CREATED A HOLE... | |||
| LATH /BRICK FLASHING | 09/13/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 09/12/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: NO PLANS OR PERMIT POSTED | |||
| ALL ROUGH | 09/07/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS IS A REINSPECTION requested by contractor at the countet CHECK STRAPS ON WIRES ON ENTRY | |||
| ALL ROUGH | 08/31/2007 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: Not ready | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/22/2007 | APPROVED | JGIBSON |
| LINTEL | 08/09/2007 | APPROVED | JGIBSON |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/26/2007 | APPROVED | ACOOPER |
| Note: 1) SLAB IS SEVERAL FEET LARGER THAN SHOWN ON PLAN. OBTAIN REVISION FOR SAME. 2) BATHROOM IS NOT SHOWN ON APPROVED PLAN. OBTAIN REVISION FOR SAME.RECHECKED OK PER ART | |||
| FIRST ROUGH PLUMBING INSPECTION | 07/23/2007 | APPROVED | MMOORE |
| Note: CALLED BY CONTRACTOR |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/11/2007 | 09/18/2007 |
| Note: Released By: FREODICA Rev.- Revised block wall opening. | |||
| SW1 | COMPLETE | 07/12/2007 | 07/12/2007 |
| Note: Released By: LAPTEKAR | |||
| BLD | HOLD | 07/05/2007 | 07/09/2007 |
| Note: Held By: JJOSEPH 1.The floor plan shows the new addition is 32'4''x30' whereas another side indicates the new addition is 23'8'' x30'. Conflict please clarify. 2. Provide protection of openings, the florida product approval number. | |||
| ZON | COMPLETE | 07/05/2007 | 07/05/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 07/03/2007 | 07/03/2007 |
| Note: Held By: JGONZALEZ floor plan does not match drawings in file please submitt correct floor plan showing addtion and location of new concrete patio on site plan, floor drawing and engineered drawing | |||
| ZON | HOLD | 06/26/2007 | 06/28/2007 |
| Note: Held By: JGONZALEZ need floor plan showing exsisting | |||
| BLD | COMPLETE | 07/10/2007 | |
| Note: Released By: LWOODROME approved as noted on plan cover sheet. Checked by Auba |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/06/2008 |
| REINSPECTION FEE | ¤40.00 | 01/08/2008 |
| REINSPECTION FEE | ¤40.00 | 01/08/2008 |
| REVISION | ¤40.00 | 01/08/2008 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/13/2007 |
| ADMIN FEE | ¤20.00 | 07/13/2007 |
| ARC RESIDENTIAL ALTERATION | ¤50.00 | 07/13/2007 |
| BUILDING CODE ADMIN FUND | ¤8.28 | 07/13/2007 |
| ELECTRIC FEE | ¤88.20 | 07/13/2007 |
| MECHANICAL FEE | ¤88.20 | 07/13/2007 |
| PERMIT FEE | ¤582.00 | 07/13/2007 |
| PLAN CHECK FEE | ¤40.00 | 07/13/2007 |
| PLUMBING FEE | ¤88.20 | 07/13/2007 |
| RADON FEE | ¤8.28 | 07/13/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,208.16 |