Permit Details
Status: COED
| Parcel Id: 07-11-31-7031-00380-0060 |
| CONDITIONED SPACE: 1597 sqft |
| GARAGE: 428 sqft |
| OPENED PORCH (WITH ROOF) : 190 sqft |
| OPENED PORCH (WITH ROOF) : 35 sqft |
| Total Square Footage: 2250 sqft |
| Block: 00380 |
| Subdivision: - |
| Job Phone: (386)851-7940 |
| Location Address: 11 RICHFIELD LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/12/2007 |
| NOC: RECORDED |
| Applicant name: LISA MARIE STEINER |
| Owner: MERCEDES HOMES, INC |
|
Address 775 HARLEY STRICKLAND BLVD ORANGE CITY, FL 32763 |
|
Address SUITE 110 ORANGE CITY, FL 32763 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MERCEDES HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12001 SCIENCE DRIVE #160 ORLANDO, FL 32826 |
CGC1510145 (Exp: 08/31/2012) | (407)272-5591 | (407)282-1563 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
EDDIE T PALMATEER
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
2985 ENTERPRISE ROAD DEBARY, FL 32713 |
SUITE A DEBARY, FL 32713 |
CAC1813533 (Exp: 08/31/2024) | (386)668-8651 | (386)668-7758 |
LISA MARIE STEINER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12001 SCIENCE DRIVE #160 ORLANDO, FL 32826 |
CGC1510145 (Exp: 08/31/2012) | (407)272-5591 | (407)282-1563 |
DAVID RAYMOND BARSANO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
600 S. VOLUSIA AVENUE ORANGE CITY, FL 32763 |
CFC055682 (Exp: 08/31/2012) | (386)774-8080 | (386)774-8189 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 01/11/2008 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 01/10/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: NEED SHOCK ARRESTER FOR DISHWASHER, MASTER BEDROOM RECEPTACLE BEHIND DOOR IS NOT ARC FAULT PROTECTED | |||
| STORMWATER FINAL INSPECTION | 01/09/2008 | APPROVED | GLALIMA |
| UTILITY COMPANY FINAL | 01/03/2008 | APPROVED - AS NOTED | MBACON |
| Note: Needs Pump Install and Bore and Tap. | |||
| RESIDENTIAL EARLY POWER | 12/21/2007 | APPROVED | RMARVEL |
| PRE DRIVEWAY | 12/07/2007 | APPROVED | GLALIMA |
| LATH /BRICK FLASHING | 11/27/2007 | APPROVED | CMINI |
| INSULATION INSPECTION | 11/20/2007 | APPROVED | MMOORE |
| ALL ROUGH | 11/16/2007 | APPROVED - AS NOTED | ACOOPER |
| Note: Add tapcon to garage buck. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/09/2007 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/08/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY. INCOMPLETE/COURTESY LIST FOLLOWS: 1) OFFSET STRAPS ON GARAGE GABLE. STRAP FROM OUTSIDE WITH TAPCONS OR ANOTHER APPROVED METHOD. 2) 3/8" TO 1/2" GAP UNDER GARAGE GABLE TRUSS. GROUT AS NEEDED. 3) POPPED NAILS ON GARAGE GABLE SHEATHING. RE-NAIL AS NEEDED. 4) SHORT BOX TRUSSES AT EITHER SIDE OF A/C ENCLOSURE ARE INADEQUATELY NAILED OFF. 5) RIGHT HAND GABLE MISSING BLOCKING TOP AND BOTTOM. SEE GABLE DETAIL SHEET T3. 6) STRAP IS FIELD BENT AT LEFT SIDE OF 2-PLY TRUSS GMAC. 7) RIDGE POLE AND ASSOCIATED RAFTERS AT FRONT ENTRY IS MISSING UPLIFT STRAPPING. | |||
| LINTEL | 10/29/2007 | APPROVED | PGALLMANN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 10/24/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/15/2007 | APPROVED - AS NOTED | ACOOPER |
| Note: STILL AWAITING SUBMITTED PAPERWORK ON EXTRA SINK IN GARAGE. | |||
| FIRST ROUGH PLUMBING INSPECTION | 10/12/2007 | APPROVED - AS NOTED | ACOOPER |
| Note: Extra plumbing for a sink in the rear of the garage will have to be approved by building dept. prior to next inspection. | |||
| TEMPORARY POLE | 10/05/2007 | APPROVED | LHITES |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/12/2007 | 10/16/2007 |
| Note: Released By: FREODICA Rev.- Added preplumb laundry tub at garage. | |||
| BLD | COMPLETE | 08/13/2007 | 08/16/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 08/09/2007 | 08/13/2007 |
| Note: Released By: JGONZALEZ | |||
| SW1 | COMPLETE | 07/20/2007 | 07/20/2007 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 07/20/2007 | 07/24/2007 |
| Note: Held By: ECOYNE need rear setback |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 01/14/2008 |
| REINSPECTION FEE | ¤40.00 | 01/14/2008 |
| REINSPECTION FEE | ¤40.00 | 01/14/2008 |
| REVISION | ¤40.00 | 01/14/2008 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/12/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/12/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 09/12/2007 |
| ADDITIONAL FEE | ¤40.00 | 09/12/2007 |
| ADMIN FEE | ¤20.00 | 09/12/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 09/12/2007 |
| BUILDING CODE ADMIN FUND | ¤11.25 | 09/12/2007 |
| ELECTRIC FEE | ¤138.00 | 09/12/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 09/12/2007 |
| MECHANICAL FEE | ¤138.00 | 09/12/2007 |
| PERMIT FEE | ¤702.00 | 09/12/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 09/12/2007 |
| PLAN CHECK FEE | ¤72.00 | 09/12/2007 |
| PLUMBING FEE | ¤138.00 | 09/12/2007 |
| RADON FEE | ¤11.25 | 09/12/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,248.55 |