I want to search for...

Permit #2007070525

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7032-00240-0140
CONDITIONED SPACE: 416 sqft
Block: 00240
Subdivision: -
Job Phone: (386)445-7343
Location Address: 29 ROYAL OAK DR
Type: BA - BUILDING ADDITION
Issue Date: 08/03/2007
NOC: RECORDED
Applicant name: BURTON ROBERT BERMAN
Owner: DILORETO, EDMUND N JR & NICOLETTE M

Address

29 ROYAL OAK DR

PALM COAST, FL 32164

Lot: 0140
Contracted Stated Job Value: ¤40,000.00
Job Description: BUILDING ADDITION
Type: CN

Contractor

PALM COAST HOMES & DEVELOPMENT CORP.
Status Location Address State License Number Phone
CANCEL

138 PALM COAST PARKWAY NE # 348

PALM COAST, FL 32137

CRC1326612 (Exp: 08/31/2012) (386)445-7343

Sub Contractors

KURT A UMBACH
Status Location Address State License Number Phone Fax
HOLD

110 Foster Lane

Palm Coast, FL 32137

EC13003356 (Exp: 08/31/2020) (386) 446-3616 (386)446-3548

Inspection History

Type Request Date Result Inspector
FINAL INSPECTION (MISC) 03/04/2008 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FINAL INSPECTION (MISC) 02/18/2008 Disapproved -FEE REQUIRED LHITES
Note: NEED REVISION FOR LEFT SIDE DOOR SWING ALSO NEED SHOWN ON PLANS THE CEILING FANS AND WHERE THEY ARE SWITCHED FROM
STORMWATER FINAL INSPECTION 02/14/2008 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION 2 / 15 / 08 REMOVE TOILET
STORMWATER FINAL INSPECTION 02/12/2008 Disapproved -FEE REQUIRED GLALIMA
Note: THIS IS A REINSPECTION / REMOVE ALL TRASH / ROOFING / CONCRETE AND ALL OTHER
UTILITY COMPANY FINAL 02/07/2008 APPROVED TSCHWEERS
Note: gravity ok.
STORMWATER FINAL INSPECTION 02/07/2008 Disapproved -FEE REQUIRED GLALIMA
Note: FAILED GRADE AND ALL DRAINAGE . SPOKE WITH BUILDER.
ALL ROUGH 02/06/2008 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
2ND ROUGH ELECTRICAL 12/13/2007 Disapproved -FEE REQUIRED RMARVEL
Note: CEILING ELECTRIC IS GOOD. ALL PVC PIPE WHERE SUBJECT TO PHYSICAL DAMAGE NEEDS TO BE SCHEDULE 80. REMOVE COVER PLATES AND DEVICES TO CHECK FOR USE OF BUSHINGS AND/OR CONNECTORS ON ENCLOSURES.
ALL ROUGH 11/30/2007 Disapproved -FEE REQUIRED ACOOPER
Note: not ready. install electrical to current NEC 2005 210.52. doors windows and frames to be installed in a manner to allow inspection of anchoring system.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/29/2007 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 10/29/2007 APPROVED JHINDMAN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/23/2007 Disapproved -FEE REQUIRED ACOOPER
Note: NEED ENGINEERING LETTER FOR CHANGES SUBMITTED TO CITY AND ADD 2.5`S IN HAND FRAMING AREA AT PEAK OVER EXISTING STRUCTURE. OK TO LATH COLUMNS.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/02/2007 Disapproved -FEE REQUIRED PGALLMANN
Note: THIS IS A REINSPECTION... 1) SPLICES IN REAR HEADER DON`T BREAK ON A COLUMN. 2) INSUFFICIENT HEADER BEARING AT OUTSIDE CORNER COLUMNS. 3) INSTALLATION OF ANGLE BRACKETS USED TO TIE-IN NEW STRUCTURE TO EXISTING IS INCOMPLETE. 4) UPLIFT HARDWARE MISSING BETWEEN RIDGE POLE AND MANUFACTURED TRUSS. 5) LEGS AND/OR COLLAR TIES MISSING UNDER HAND FRAMING.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/25/2007 CANCELLED BY APPLICANT PGALLMANN
MONOLITHIC SLAB INSPECTION/SLAB 08/31/2007 APPROVED JHINDMAN

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/03/2008 03/03/2008
Note: Released By: SKNOPF Approved for Release. Revision: Added receptacles, ceiling fans and switches to sunroom.
BLD COMPLETE 10/25/2007 10/25/2007
Note: Released By: FREODICA Rev.- Added 2x4 on ech side of 4x4 post, splicing 2x12 header and added valley/rafter detail.
BLD COMPLETE 08/01/2007 08/02/2007
Note: Released By: CCOTE Approved for Release. Review by Auba.
SW1 HOLD 07/31/2007 07/31/2007
Note: Held By: LAPTEKAR Right of way access application required for building additions.
SW1 COMPLETE 07/31/2007 08/01/2007
Note: Released By: LAPTEKAR RECEIVED COMPLETED ROW APPLICATION
ZON COMPLETE 07/30/2007 07/30/2007
Note: Released By: JGONZALEZ
ZON HOLD 07/26/2007 07/27/2007
Note: Held By: ECOYNE Need to eliminate shed from survey - cannot locate shed permit.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/21/2008
REINSPECTION FEE ¤40.00 05/21/2008
REINSPECTION FEE ¤40.00 05/21/2008
REINSPECTION FEE ¤40.00 05/21/2008
REINSPECTION FEE ¤40.00 05/21/2008
REVISION ¤40.00 05/21/2008
STORMWATER REINSPECTION FEE ¤35.00 05/21/2008
STORMWATER REINSPECTION FEE ¤35.00 05/21/2008
STORM WATER PERMIT FEES ¤80.00 08/03/2007
ADMIN FEE ¤20.00 08/03/2007
ARC RESIDENTIAL ALTERATION ¤50.00 08/03/2007
ELECTRIC FEE ¤54.00 08/03/2007
PERMIT FEE ¤240.00 08/03/2007
PLAN CHECK FEE ¤40.00 08/03/2007
Fees Total Due: ¤0.00 Total Paid: ¤794.00