Permit #2007070525
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7032-00240-0140 |
| CONDITIONED SPACE: 416 sqft |
| Block: 00240 |
| Subdivision: - |
| Job Phone: (386)445-7343 |
| Location Address: 29 ROYAL OAK DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 08/03/2007 |
| NOC: RECORDED |
| Applicant name: BURTON ROBERT BERMAN |
| Owner: DILORETO, EDMUND N JR & NICOLETTE M |
|
Address 29 ROYAL OAK DR PALM COAST, FL 32164 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤40,000.00 |
| Job Description: BUILDING ADDITION |
| Type: CN |
Contractor
PALM COAST HOMES & DEVELOPMENT CORP.
| Status | Location Address | State License Number | Phone |
| CANCEL |
138 PALM COAST PARKWAY NE # 348 PALM COAST, FL 32137 |
CRC1326612 (Exp: 08/31/2012) | (386)445-7343 |
Sub Contractors
KURT A UMBACH
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
110 Foster Lane Palm Coast, FL 32137 |
EC13003356 (Exp: 08/31/2020) | (386) 446-3616 | (386)446-3548 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL INSPECTION (MISC) | 03/04/2008 | FINAL APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| FINAL INSPECTION (MISC) | 02/18/2008 | Disapproved -FEE REQUIRED | LHITES |
| Note: NEED REVISION FOR LEFT SIDE DOOR SWING ALSO NEED SHOWN ON PLANS THE CEILING FANS AND WHERE THEY ARE SWITCHED FROM | |||
| STORMWATER FINAL INSPECTION | 02/14/2008 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 2 / 15 / 08 REMOVE TOILET | |||
| STORMWATER FINAL INSPECTION | 02/12/2008 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: THIS IS A REINSPECTION / REMOVE ALL TRASH / ROOFING / CONCRETE AND ALL OTHER | |||
| UTILITY COMPANY FINAL | 02/07/2008 | APPROVED | TSCHWEERS |
| Note: gravity ok. | |||
| STORMWATER FINAL INSPECTION | 02/07/2008 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: FAILED GRADE AND ALL DRAINAGE . SPOKE WITH BUILDER. | |||
| ALL ROUGH | 02/06/2008 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| 2ND ROUGH ELECTRICAL | 12/13/2007 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: CEILING ELECTRIC IS GOOD. ALL PVC PIPE WHERE SUBJECT TO PHYSICAL DAMAGE NEEDS TO BE SCHEDULE 80. REMOVE COVER PLATES AND DEVICES TO CHECK FOR USE OF BUSHINGS AND/OR CONNECTORS ON ENCLOSURES. | |||
| ALL ROUGH | 11/30/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: not ready. install electrical to current NEC 2005 210.52. doors windows and frames to be installed in a manner to allow inspection of anchoring system. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/29/2007 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 10/29/2007 | APPROVED | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/23/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: NEED ENGINEERING LETTER FOR CHANGES SUBMITTED TO CITY AND ADD 2.5`S IN HAND FRAMING AREA AT PEAK OVER EXISTING STRUCTURE. OK TO LATH COLUMNS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/02/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: THIS IS A REINSPECTION... 1) SPLICES IN REAR HEADER DON`T BREAK ON A COLUMN. 2) INSUFFICIENT HEADER BEARING AT OUTSIDE CORNER COLUMNS. 3) INSTALLATION OF ANGLE BRACKETS USED TO TIE-IN NEW STRUCTURE TO EXISTING IS INCOMPLETE. 4) UPLIFT HARDWARE MISSING BETWEEN RIDGE POLE AND MANUFACTURED TRUSS. 5) LEGS AND/OR COLLAR TIES MISSING UNDER HAND FRAMING. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/25/2007 | CANCELLED BY APPLICANT | PGALLMANN |
| MONOLITHIC SLAB INSPECTION/SLAB | 08/31/2007 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 03/03/2008 | 03/03/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision: Added receptacles, ceiling fans and switches to sunroom. | |||
| BLD | COMPLETE | 10/25/2007 | 10/25/2007 |
| Note: Released By: FREODICA Rev.- Added 2x4 on ech side of 4x4 post, splicing 2x12 header and added valley/rafter detail. | |||
| BLD | COMPLETE | 08/01/2007 | 08/02/2007 |
| Note: Released By: CCOTE Approved for Release. Review by Auba. | |||
| SW1 | HOLD | 07/31/2007 | 07/31/2007 |
| Note: Held By: LAPTEKAR Right of way access application required for building additions. | |||
| SW1 | COMPLETE | 07/31/2007 | 08/01/2007 |
| Note: Released By: LAPTEKAR RECEIVED COMPLETED ROW APPLICATION | |||
| ZON | COMPLETE | 07/30/2007 | 07/30/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 07/26/2007 | 07/27/2007 |
| Note: Held By: ECOYNE Need to eliminate shed from survey - cannot locate shed permit. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/21/2008 |
| REINSPECTION FEE | ¤40.00 | 05/21/2008 |
| REINSPECTION FEE | ¤40.00 | 05/21/2008 |
| REINSPECTION FEE | ¤40.00 | 05/21/2008 |
| REINSPECTION FEE | ¤40.00 | 05/21/2008 |
| REVISION | ¤40.00 | 05/21/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/21/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/21/2008 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/03/2007 |
| ADMIN FEE | ¤20.00 | 08/03/2007 |
| ARC RESIDENTIAL ALTERATION | ¤50.00 | 08/03/2007 |
| ELECTRIC FEE | ¤54.00 | 08/03/2007 |
| PERMIT FEE | ¤240.00 | 08/03/2007 |
| PLAN CHECK FEE | ¤40.00 | 08/03/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤794.00 |