I want to search for...
Permit #2007080086
Permit Details
Status: COED
| Parcel Id: 07-11-31-7032-00850-0110 |
| CONDITIONED SPACE: 2976 sqft |
| GARAGE: 435 sqft |
| OPENED PORCH (WITH ROOF) : 400 sqft |
| OPENED PORCH (WITH ROOF) : 21 sqft |
| Total Square Footage: 3832 sqft |
| Block: 00850 |
| Subdivision: - |
| Job Phone: (386)254-5081 |
| Location Address: 70 ROLLING FERN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/17/2007 |
| NOC: RECORDED |
| Applicant name: WAYNE LAWRENCE ADAMS |
| Owner: ADAMS HOMES |
|
Address 3000 GULF BREEZE PARKWAY GULF BREEZE, FL 32563 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤289,500.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
ADAMS HOMES OF NW FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1101 Gulf Breeze Parkway Suite 229 Gulf Breeze, FL 32561 |
CBC043518 (Exp: 08/31/2014) | (386)254-5081 | (386)252-8284 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
HERSEL L GARDNER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
939 ALEXANDER AVE. DAYTONA BCH, FL 32129 |
CFC033859 (Exp: 08/31/2010) | (386) 761-6049 | (386)767-9972 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 01/24/2008 | FINAL APPROVED | ACOOPER |
| STORMWATER FINAL INSPECTION | 01/23/2008 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 01/18/2008 | APPROVED | TSCHWEERS |
| Note: Gravity ok. | |||
| STORMWATER FINAL INSPECTION | 01/18/2008 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: No damages noted on 10/16/07 per GL REMOVE ALL CONCRETE / GROUT FROM INSIDE CULVERT PIPE , REMOVE ALL NAILS FROM FROMS IN DRIVE THIS A TRIPING '' HAZARD . BECAUSE OF SLOP IN REAR RIGHT AT AND AROUND WATER METER YOU SHOULD PLACE SOD. FAILED BEACAUSE OF # 8 A AND # 11 . | |||
| PRE DRIVEWAY | 01/04/2008 | APPROVED - AS NOTED | GLALIMA |
| Note: DO NOTFILL IN ROAD WITH CONCRETE , SEE PAINT . | |||
| RESIDENTIAL EARLY POWER | 01/03/2008 | APPROVED | RMARVEL |
| INSULATION INSPECTION | 12/04/2007 | APPROVED | MMOORE |
| INSULATION INSPECTION | 12/03/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Fireblock A/C plentum all the way around. | |||
| LATH /BRICK FLASHING | 11/28/2007 | APPROVED | JHINDMAN |
| ALL ROUGH | 11/28/2007 | APPROVED | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/28/2007 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 11/14/2007 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/14/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. ANCHOR BOLTS REQUIRED AT THE FRONT DOOR FRAMING AT BOTH SIDES AT 6" MAX FROM END OF 2X4 P.T. PLATE 2. PAGE/ SHEET 2 OF 9 AT ENDS OF LANAI BEAMS (MARKED IN RED) WRONG HANGERS / ALSO REQUIRES CORNER POSTS. NEED CLARIFICATION OF "CORNER POST" NEED REVISION TO DETERMINE SIZE | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 11/13/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/31/2007 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 10/26/2007 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| SW1 | CANCEL | 12/26/2007 | |
| Note: received new topo surveys | |||
| SW1 | HOLD | 12/07/2007 | 12/07/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are low by more than 10 feet. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| BLD | COMPLETE | 11/26/2007 | 11/27/2007 |
| Note: Released By: FREODICA Rev.- Revised beam 2 at lanai from 2-ply to 3-ply and connectors. | |||
| ZON | COMPLETE | 10/11/2007 | 10/11/2007 |
| Note: Released By: JGONZALEZ per barbara grossman member of dcc jgonzalez | |||
| BLD | COMPLETE | 10/11/2007 | 10/12/2007 |
| Note: Released By: FREODICA Reviewed by Auba. | |||
| SW1 | COMPLETE | 10/05/2007 | 10/08/2007 |
| Note: Released By: LAPTEKAR received new topo survey/ swale and culvert proposals are off..approved as noted | |||
| SW1 | HOLD | 09/26/2007 | 09/26/2007 |
| Note: Held By: LAPTEKAR received new driveway detail plan still need corrected topo survey with the correct FFE of lot #10 next door | |||
| SW1 | HOLD | 09/04/2007 | 09/06/2007 |
| Note: Held By: LAPTEKAR 1.FFE of lot #10 appears to be a typo 2.Driveway detail is city sample/please modify to incorporate company logo and details specific to Adams Homes/ | |||
| ZON | HOLD | 08/03/2007 | 08/08/2007 |
| Note: Held By: ECOYNE plans show covered lanai 400 sq ft survey shows patio 210 sq ft need landscaping plans along left elevation facing Robinson Dr. same style home on lot 10, need to change front elevation, brick, etc. | |||
| ZON | HOLD | 09/04/2007 | |
| Note: Held By: ECOYNE received new survey with c orrected landscaping need to address similiar house on Lot 10, also need to adddress patio showing on survey, not showing on plans, also having covered lanai on area calculations, not in plans or survey. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 01/28/2008 |
| REINSPECTION FEE | ¤40.00 | 01/28/2008 |
| REINSPECTION FEE | ¤40.00 | 01/28/2008 |
| REVISION | ¤40.00 | 01/28/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 01/28/2008 |
| SW REVISION | ¤40.00 | 01/28/2008 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 10/17/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/17/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/17/2007 |
| ADMIN FEE | ¤20.00 | 10/17/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 10/17/2007 |
| BUILDING CODE ADMIN FUND | ¤19.16 | 10/17/2007 |
| ELECTRIC FEE | ¤204.00 | 10/17/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 10/17/2007 |
| MECHANICAL FEE | ¤204.00 | 10/17/2007 |
| PERMIT FEE | ¤1,131.00 | 10/17/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 10/17/2007 |
| PLAN CHECK FEE | ¤116.00 | 10/17/2007 |
| PLUMBING FEE | ¤204.00 | 10/17/2007 |
| RADON FEE | ¤19.16 | 10/17/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,970.37 |