Location Address: 70 BROWNSTONE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/06/2007
NOC: RECORDED
Applicant name: WAYNE LAWRENCE ADAMS
Owner: ADAMS HOMES OF NORTHWEST FLORIDA INC

Address

3000 GULF BREEZE PKWY

GULF BREEZE, FL 32563

Lot: 0480
Contracted Stated Job Value: ¤243,000.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

ADAMS HOMES OF NW FLORIDA INC
Status Location Address State License Number Phone Fax
INACTIVE

1101 Gulf Breeze Parkway Suite 229

Gulf Breeze, FL 32561

CBC043518 (Exp: 08/31/2014) (386)254-5081 (386)252-8284

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
HERSEL L GARDNER
Status Location Address State License Number Phone Fax
CANCEL

939 ALEXANDER AVE.

DAYTONA BCH, FL 32129

CFC033859 (Exp: 08/31/2010) (386) 761-6049 (386)767-9972
MILLARD K KELLER
Status Location Address State License Number Phone Fax
CANCEL

313 S. VOLUSIA AVENUE

DELAND, FL 32724

CCC1325778 (Exp: 08/31/2010) (386) 774-9961 (386)774-2388

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 01/24/2008 FINAL APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 01/22/2008 Disapproved -FEE REQUIRED ACOOPER
Note: MISSING BUSHING BEHIND A/C DISCONNECT AND ATTIC STEPS NEED A FIRE RATING EQUAL TO THE CEILING OR BETTER.
STORMWATER FINAL INSPECTION 01/18/2008 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 01/17/2008 Disapproved -FEE REQUIRED DRANDALL
Note: remove all trash & construction debris from left, rear, & right adj. property [see pink paint]
UTILITY COMPANY FINAL 01/15/2008 APPROVED TSCHWEERS
Note: Gravity ok.
PRE DRIVEWAY 12/20/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
PRE DRIVEWAY 12/19/2007 Disapproved -FEE REQUIRED DRANDALL
Note: need 5" of concrete above pipe.....need 6" of space at end of culvert pipe to forms.....need 6" down, 6" back pit for steel.....need 90* cut at road edge not 45*
RESIDENTIAL EARLY POWER 12/11/2007 APPROVED JHINDMAN
INSULATION INSPECTION 11/13/2007 APPROVED ACOOPER
ALL ROUGH 11/13/2007 APPROVED ACOOPER
LATH /BRICK FLASHING 11/08/2007 APPROVED DROCKWELL
ALL ROUGH 11/08/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: CLOSE ALL UNSED OPENINGS. STRAP NM CABLE WHERE NOT SUPPORTED EVERY 4.5FT. DAMAGED NM CABLE IN BATHROOM. REMOVE KINKED/DAMAGED NM CABLE. RECHECK NAIL PLATES. PROPERLY ATTACH DUCT TO EXHAUST FAN. EXTEND PVC COMING OUT OF FLOOR IN KITCHEN TO 6IN. REMOVE NAIL STRAP FROM GUSSETT PLATE IN KITCHEN. DONOT STAPLE NM CABLE ON EDGE. EXHAUST FAN DUCT NEEDS TO TERMINATE OUTSIDE OF THE BUILDING.
EXTERIOR WALL SHEATHING/SHEAR WALL 10/31/2007 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/31/2007 APPROVED MMOORE
EXTERIOR WALL SHEATHING/SHEAR WALL 10/30/2007 APPROVED MMOORE
FOUNDATION SURVEY APPROVED BY STORMWATER 10/30/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 10/17/2007 APPROVED ACOOPER
FIRST ROUGH PLUMBING INSPECTION 10/15/2007 APPROVED JLEVRAULT

Review History

Department Status Date In Date Out
ZON COMPLETE 12/26/2007 12/26/2007
Note: Released By: ECOYNE
SW1 COMPLETE 12/13/2007 12/14/2007
Note: Released By: EBLACKER received new topo surveys
ZON HOLD 12/06/2007 12/06/2007
Note: Held By: ECOYNE revision submitted add circular driveway - sealed survey showed different setbacks w/o patio need a/c pad notes on survey
SW1 HOLD 11/19/2007 11/19/2007
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are higher than expected by an average of 0.62ft. and there is no reference made to NAVD of 1988 as required. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
SW1 HOLD 10/05/2007 10/09/2007
Note: Held By: LAPTEKAR Proposed circular driveway needs dimensions of driveway addition on the site plan to ensure city minimum width of 10 feet at the property line and 16' flair at the road are met. Placed revision sheet in builder's box faxed 10/9/07 and called
BLD COMPLETE 10/02/2007 10/02/2007
Note: Released By: FREODICA Rev.- clarification of strapping on detail 1 of sheet S-2 & S-3.
BLD COMPLETE 09/04/2007 09/06/2007
Note: Released By: FREODICA Approved for release. Reviewed by Auba.
ZON COMPLETE 09/04/2007 09/04/2007
Note: Released By: JGONZALEZ
SW1 COMPLETE 08/16/2007 08/16/2007
Note: Released By: WKINELL
SW1 HOLD 08/07/2007 08/08/2007
Note: Held By: WKINELL The proposed FFE of 101.50 ft exceeds the maximum allowable residential building height of 35 ft. The proposed FFE may be a typographical error. Nail and disk in the roadway is not an acceptable elevation benchmark. Benchmark must be on power pole, fire hydrant or rim of man hole and referenced to NAVD 1988 datum. Benchmark must be clearly identified and exact location described, i.e., top flange of hydrant, north rim of manhole, etc. The site plan does not appear to state proposed finished grade elevations, a Lot Grading Plan (LGP) is required. The site plan does not include suffucient proposed elevations in the rear yard to demonstrate adequate stormwater drainage away from the house. All stormwater must be contained onsite and directed from the rear, to the front swale. It would be a great benefit if the house number were stated on all survey documents. Please submit corrected topo survey/LGP, to the Stormwater Department, that addresses the above listed issues.//wk
ZON HOLD 08/03/2007 08/07/2007
Note: Held By: JGONZALEZ need rear property setbacks need a/c pad and concrete locations on site plans with setbacks

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 01/24/2008
REINSPECTION FEE ¤40.00 01/24/2008
REINSPECTION FEE ¤40.00 01/24/2008
REINSPECTION FEE ¤40.00 01/24/2008
REVISION ¤40.00 01/24/2008
STORMWATER REINSPECTION FEE ¤35.00 01/24/2008
STORMWATER REINSPECTION FEE ¤35.00 01/24/2008
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 09/06/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 09/06/2007
STORM WATER PERMIT FEES ¤80.00 09/06/2007
ADMIN FEE ¤20.00 09/06/2007
ARC HOUSE REVIEW ¤125.00 09/06/2007
BUILDING CODE ADMIN FUND ¤17.23 09/06/2007
ELECTRIC FEE ¤194.40 09/06/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 09/06/2007
MECHANICAL FEE ¤194.40 09/06/2007
PERMIT FEE ¤1,068.60 09/06/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 09/06/2007
PLAN CHECK FEE ¤109.60 09/06/2007
PLUMBING FEE ¤194.40 09/06/2007
RADON FEE ¤17.23 09/06/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,903.91