I want to search for...
Permit #2007080254
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7028-00390-0040 |
| CONDITIONED SPACE: 2270 sqft |
| GARAGE: 452 sqft |
| OPENED PORCH (WITH ROOF) : 200 sqft |
| OPENED PORCH (WITH ROOF) : 24 sqft |
| Total Square Footage: 2946 sqft |
| Block: 00390 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 67 POST VIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/28/2007 |
| NOC: RECORDED |
| Applicant name: GREGORY JOSEPH SEAL |
| Owner: MASTERPIECE HOMES INC |
|
Address PO BOX 740618 ORANGE CITY, FL 32774 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤141,486.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
MASTERPIECE HOMES INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 740618 ORANGE CITY, FL 32763 |
CRC1327666 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
Inspection History
| Type | Request Date | Result | Inspector |
| PROJECT STATUS INSPECTION | 12/14/2007 | Disapproved - NO FEE | JHINDMAN |
| Note: VACANT LOT,IT HAS NOT BEEN CLEARED, NO SAFETY ISSUES OBSERVED | |||
| PROJECT STATUS INSPECTION | |||
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | |||
| LATH /BRICK FLASHING | |||
| LINTEL | |||
| ALL ROUGH | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | |||
| RESIDENTIAL EARLY POWER | |||
| INSULATION INSPECTION | |||
| PRE DRIVEWAY | |||
| STORMWATER FINAL INSPECTION | |||
| UTILITY COMPANY FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/17/2007 | 09/19/2007 |
| Note: Released By: FREODICA Approved for release. Reviewed by Auba. | |||
| SW1 | COMPLETE | 08/23/2007 | 08/24/2007 |
| Note: Released By: LAPTEKAR Received new survey clearly labeling benchmark. | |||
| ZON | COMPLETE | 08/16/2007 | 08/23/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 08/13/2007 | 08/14/2007 |
| Note: Held By: BBARTON/training 1. A/C pad needs to be shown on Survey 2. Need Front Door Color | |||
| BLD | HOLD | 08/28/2007 | |
| Note: Held By: JJOSEPH 1.All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Decorative Cementituous Coating is not an approved covering over wood sheathing, however stucco is acceptable if applied per ASTM C926 and the following criteria: a.Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. b.Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. c.Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. 2 How do you comply to section R-703 .12 regarding Joist details at section F/S4 for flashing. 3.Provide protection of openings include the Florida Product Approval Number or Hurricane Shutter . | |||
| SW1 | HOLD | 08/16/2007 | |
| Note: Held By: LAPTEKAR All flat work needs to be indicated on survey. Benchmark needs to be clearly labeled...which power pole? Missing driveway detail plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 09/28/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 09/28/2007 |
| BUILDING CODE ADMIN FUND | ¤14.73 | 09/28/2007 |
| ELECTRIC FEE | ¤161.40 | 09/28/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 09/28/2007 |
| MECHANICAL FEE | ¤161.40 | 09/28/2007 |
| PERMIT FEE | ¤854.10 | 09/28/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 09/28/2007 |
| PLAN CHECK FEE | ¤87.60 | 09/28/2007 |
| PLUMBING FEE | ¤161.40 | 09/28/2007 |
| RADON FEE | ¤14.73 | 09/28/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/28/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/28/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 09/28/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,293.41 |