I want to search for...
Permit #2007080263
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7028-00590-0340 |
| CONDITIONED SPACE: 2607 sqft |
| GARAGE: 459 sqft |
| OPENED PORCH (WITH ROOF) : 180 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 3296 sqft |
| Block: 00590 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 179 POINT PLEASANT DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/10/2007 |
| NOC: RECORDED |
| Applicant name: GREGORY JOSEPH SEAL |
| Owner: MASTERPIECE HOMES INC |
|
Address PO BOX 740618 ORANGE CITY, FL 32774 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤157,984.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MASTERPIECE HOMES INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 740618 ORANGE CITY, FL 32763 |
CRC1327666 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
Inspection History
| Type | Request Date | Result | Inspector |
| PROJECT STATUS INSPECTION | 12/14/2007 | Disapproved - NO FEE | JHINDMAN |
| Note: VACANT UNCLEARED LOT, NO SAFETY ISSUES OBSERVED | |||
| PROJECT STATUS INSPECTION | |||
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | |||
| LATH /BRICK FLASHING | |||
| LINTEL | |||
| ALL ROUGH | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | |||
| RESIDENTIAL EARLY POWER | |||
| INSULATION INSPECTION | |||
| PRE DRIVEWAY | |||
| STORMWATER FINAL INSPECTION | |||
| UTILITY COMPANY FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/18/2007 | 09/21/2007 |
| Note: Released By: LAPTEKAR received corrected survey/// approved as noted: proposed elevations for the swale are high | |||
| BLD | COMPLETE | 09/17/2007 | 09/19/2007 |
| Note: Released By: FREODICA Approved for release. Reviewed by Auba. | |||
| BLD | HOLD | 08/21/2007 | 08/22/2007 |
| Note: Held By: JJOSEPH Provide protection of openings and Florida Product Approval Number. If the windows are not impact resistant or large missile impact, submit Hurricane Shutter and Florida Product Approval Number. | |||
| ZON | COMPLETE | 08/20/2007 | 08/21/2007 |
| Note: Released By: ECOYNE | |||
| SW1 | HOLD | 08/13/2007 | 08/16/2007 |
| Note: Held By: LAPTEKAR Survey has error in identifying the adjacent lot #...both are 35? | |||
| ZON | HOLD | 08/13/2007 | 08/14/2007 |
| Note: Held By: BBARTON/training 1. All surveys provided are incorrect. Both lots on either side of this property can not be lot 35. New surveys are required. 2. What is the purpose of the 3x3 concrete slab that is on the survey but not on the plans? Does it need to be removed from the survey? | |||
| BLD | HOLD | 08/22/2007 | |
| Note: Held By: JJOSEPH 1. In the Energy calculation , Precise the wall type at the first floor since frame wood appears for both first and second floor. 2.Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. 3.Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. 4.Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. 5 How do you comply to section R-703 .12 regarding Joist details at section F/S4 for flashing. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 10/10/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 10/10/2007 |
| BUILDING CODE ADMIN FUND | ¤16.48 | 10/10/2007 |
| ELECTRIC FEE | ¤178.80 | 10/10/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 10/10/2007 |
| MECHANICAL FEE | ¤178.80 | 10/10/2007 |
| PERMIT FEE | ¤967.20 | 10/10/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 10/10/2007 |
| PLAN CHECK FEE | ¤99.20 | 10/10/2007 |
| PLUMBING FEE | ¤178.80 | 10/10/2007 |
| RADON FEE | ¤16.48 | 10/10/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/10/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/10/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 10/10/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,473.81 |