Permit #2007090089
Permit Details
Status: COED
| CONDITIONED SPACE: 2643 sqft |
| GARAGE: 758 sqft |
| OPENED PORCH (WITH ROOF) : 375 sqft |
| OPENED PORCH (WITH ROOF) : 119 sqft |
| Total Square Footage: 3895 sqft |
| Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven |
| Job Phone: (386) 445-4408 |
| Location Address: 10 WATERVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/04/2007 |
| NOC: RECORDED |
| Applicant name: PATRICK E KOLLAR |
| Owner: HENRY J ISERN & |
|
Address MERRILL L STASS-ISERN (TRUSTEES) OVERLAND PARK, KS 66223 |
|
Address 13803 WOODWARD ST OVERLAND PARK, KS 66223 |
| Lot: 20 |
| Contracted Stated Job Value: ¤427,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
RED CARPET CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
8A Market Place Court Palm Coast, FL 32137 |
CRC017457 (Exp: 08/31/2026) | (386) 445-4408 | (386)446-2232 |
Sub Contractors
BEN K REIHL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
605 MCINTOSH ROAD Ormond Beach, 32174 |
EC0002867 (Exp: 08/31/2026) | (386) 677-4464 | 386-673-4199 |
SHAWN MICHAEL HISS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1315 LPGA BLVD HOLLY HILL, FL 32117 |
CAC1813585 (Exp: 08/31/2026) | (386)672-8688 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
RICHARD D MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
325 WALKER STREET HOLLY HILL, FL 32117 |
20370 (Exp: 07/12/2011) | (386)672-8494 | (386)672-0565 |
Inspection History
| Type | Request Date | Result | Inspector |
| GAS FINAL | 07/24/2008 | APPROVED | MMOORE |
| FINAL COMPLETE BUILDING INSPECTION | 07/24/2008 | FINAL APPROVED | MMOORE |
| Note: approved per signature on job card | |||
| FINAL COMPLETE BUILDING INSPECTION | 07/23/2008 | Disapproved - NO FEE | MMOORE |
| Note: Seal around toilets...smoke detectors | |||
| GAS FINAL | 07/23/2008 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. Gas valve in kitchen 2. Gas bond wire | |||
| STORMWATER FINAL INSPECTION | 07/21/2008 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 07/21/2008 | APPROVED - AS NOTED | TSCHWEERS |
| Note: Gravity ok, Permit box had wasps in it, DID NOT SIGN. | |||
| RESIDENTIAL EARLY POWER | 07/15/2008 | APPROVED | LHITES |
| GAS ROUGH | 07/14/2008 | APPROVED | MMOORE |
| Note: GAS TANK ABOVE GROUND ANDGAS LINE STUBBED INTO KITCHEN AND CAPPED-OFF / CONTRACTOR TOLD TO CALL-IN A GAS FINAL WITH HOUSE FINAL | |||
| INSULATION INSPECTION | 04/16/2008 | APPROVED | LHITES |
| Note: DRYER VENT IS OK | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/14/2008 | APPROVED | ACOOPER |
| ALL ROUGH | 04/14/2008 | APPROVED - AS NOTED | LHITES |
| Note: NEED TO SHORTEN DRYER VENT. WILL CHECK AT INSULATION | |||
| LATH /BRICK FLASHING | 03/25/2008 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/29/2008 | APPROVED - AS NOTED | DROCKWELL |
| Note: CHECK TRUSS REVISIONS AT ALL ROUGH | |||
| TUG ELECTRIC | 02/07/2008 | APPROVED | RMARVEL |
| LINTEL | 01/28/2008 | APPROVED | JGIBSON |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 01/09/2008 | APPROVED | WKINELL |
| FOUNDATION SURVEY APPROVED BY ZONING | 01/09/2008 | APPROVED | BBARTON |
| MONOLITHIC SLAB INSPECTION/SLAB | 12/28/2007 | APPROVED | RMARVEL |
| MONOLITHIC SLAB INSPECTION/SLAB | 12/27/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: CLEAN OUT CAVE-INS. MISSING DOWN RODS AT COLUMN PADS WHER CALLING FOR 2 NOT 1. | |||
| FIRST ROUGH PLUMBING INSPECTION | 12/20/2007 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/09/2008 | 04/08/2008 |
| Note: Released By: JJOSEPH R5 Insulation changes to R4 | |||
| ZON | COMPLETE | 03/12/2008 | 03/14/2008 |
| Note: Released By: ECOYNE | |||
| BLD | COMPLETE | 03/12/2008 | 03/14/2008 |
| Note: Released By: FREODICA Rev. - Added 60 gal. above ground gas tank with 1/2" CSST pipe supply to gas range of 50 kBTU load. Note: This is the 3rd revision submitted. The previous (2) revisions were not approved. See plan review comments for history. | |||
| BLD | COMPLETE | 02/29/2008 | 02/29/2008 |
| Note: Released By: JMCGOWEN truss revision | |||
| BLD | HOLD | 01/02/2008 | 01/03/2008 |
| Note: Held By: FREODICA 1. The submitted riser diagram shows total pipe lenght of only 10 ft. from the tank to the gas range. Please clarify. | |||
| BLD | HOLD | 12/14/2007 | 12/18/2007 |
| Note: Held By: FREODICA Relocate underground gas tank to meet code requirement of 10 ft away from house and 10 ft away from property line. | |||
| BLD | COMPLETE | 10/02/2007 | 10/03/2007 |
| Note: Released By: FREODICA Reviewed by Auba. | |||
| BLD | HOLD | 09/25/2007 | 09/25/2007 |
| Note: Held By: JJOSEPH 1. provide mittered glass details. 2. Provide protection of openings and Florida Product approval number. If the windows are not impact resistant, Hurricane shutter will be needed to submit and Florida Product approval number. 3. How the stucco will be applied over the exterior masonry wall? | |||
| URB | COMPLETE | 09/24/2007 | 09/25/2007 |
| Note: Released By: JBEAUDET JB TREE BARRICADES ARE NOW INSTALLED | |||
| ZON | COMPLETE | 09/17/2007 | 09/26/2007 |
| Note: Released By: ECOYNE stamp survey to show no a/c pad will be done. | |||
| URB | HOLD | 09/13/2007 | 09/14/2007 |
| Note: Held By: JBEAUDET 9/14/07 NEED TO INSTALL TREE BARRICADES AROUND ALL SAVED TREES AND CALL JOHN WITH URBAN FORESTRY FOR A REINSPECTION | |||
| ZON | COMPLETE | 09/11/2007 | 09/13/2007 |
| Note: Released By: JGONZALEZ recieved fax from builder no a/c pad because requesting a geo thermo unit. Approved site plan based on no a/c pad. If unit not approved please add zoning review and need new site plans. Jgonzalez | |||
| SW1 | COMPLETE | 09/10/2007 | 09/10/2007 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 09/07/2007 | 09/10/2007 |
| Note: Held By: JGONZALEZ need location of a/c pad on site plan Geo-thermo unit not approved the please add zoning review and return to zoning department |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 07/24/2008 |
| REINSPECTION FEE | ¤40.00 | 07/24/2008 |
| REINSPECTION FEE | ¤40.00 | 07/24/2008 |
| REVISION | ¤40.00 | 07/24/2008 |
| REVISION | ¤80.00 | 07/24/2008 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/04/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/04/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 10/04/2007 |
| ADMIN FEE | ¤20.00 | 10/04/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 10/04/2007 |
| BUILDING CODE ADMIN FUND | ¤19.48 | 10/04/2007 |
| ELECTRIC FEE | ¤286.20 | 10/04/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 10/04/2007 |
| MECHANICAL FEE | ¤286.20 | 10/04/2007 |
| PERMIT FEE | ¤1,665.30 | 10/04/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 10/04/2007 |
| PLAN CHECK FEE | ¤170.80 | 10/04/2007 |
| PLUMBING FEE | ¤286.20 | 10/04/2007 |
| RADON FEE | ¤19.48 | 10/04/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,811.71 |