I want to search for...
Permit #2007100072
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00010-0010 |
| CONDITIONED SPACE: 1902 sqft |
| CONDITIONED SPACE: 1701 sqft |
| GARAGE: 334 sqft |
| GARAGE: 312 sqft |
| OPENED PORCH (WITH ROOF) : 177 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| OPENED PORCH (WITH ROOF) : 163 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 4685 sqft |
| Block: 00010 |
| Subdivision: - |
| Job Phone: (386)445-7343 |
| Location Address: 134 FERNDALE LN |
| Type: DU - DUPLEX |
| Issue Date: 01/28/2008 |
| NOC: RECORDED |
| Applicant name: BURTON ROBERT BERMAN |
| Owner: SAMUELS, DONOVAN A |
|
Address 96 OLIVER AVENUE VALLEY STREAM, NY 11580 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: DUPLEX RESIDENCE |
| Type: CN |
Contractor
PALM COAST HOMES & DEVELOPMENT CORP.
| Status | Location Address | State License Number | Phone |
| CANCEL |
138 PALM COAST PARKWAY NE # 348 PALM COAST, FL 32137 |
CRC1326612 (Exp: 08/31/2012) | (386)445-7343 |
Sub Contractors
KURT A UMBACH
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
110 Foster Lane Palm Coast, FL 32137 |
EC13003356 (Exp: 08/31/2020) | (386) 446-3616 | (386)446-3548 |
SINCLAIR W STICKLE
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
15 HARGROVE GRADE BLD 2 UNIT G PALM COAST, FL 32137 |
CAC052428 (Exp: 08/31/2018) | 386-446-1114 | (386)446-1278 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
GEMMA CATALINA CARRASCO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
665 WEST COUNTY RD SUITE 206 BUNNELL, FL 32110 |
CCC1326074 (Exp: 08/31/2010) | (386)931-5655 | (386)206-9823 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 10/29/2008 | FINAL APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 10/27/2008 | Disapproved -FEE REQUIRED | LHITES |
| Note: THIS IS A REINSPECTION Inspection Resulted at 10/27/2008 3:06:05 PM SIDE A 1 GROUT TOILETS 2 MUST HAVE 2" CLEANOUT FINISHED. 3. MASTER BATH NEEDS TO BE ON ARC FAULT BREAKERS. 4 FILL HOLES IN BLOCK WALLS AT WELL PIPES AND INSIDE GARAGE WHERE THER IS EXPOSED REBAR 5 MASTER CLOSET NEEDS CEILING VENT COVER. SIDE B GROUT TOILETS, FINISH 2" CLEANOUTS. | |||
| UTILITY COMPANY FINAL | 10/09/2008 | APPROVED | TSCHWEERS |
| Note: REQUESTD BY CONTRACTOR Gravity ok | |||
| FINAL COMPLETE BUILDING INSPECTION | 10/09/2008 | CANCELLED BY APPLICANT | LHITES |
| Note: REQUESTED BY CONTRACTOR Inspection Resulted at 10/9/2008 2:45:35 PM MUST HAVE EARLY POWER COMPLETE BEFORE FINAL | |||
| RESIDENTIAL EARLY POWER | 10/09/2008 | APPROVED | LHITES |
| Note: REQUESTED BY CONTRACTOR | |||
| STORMWATER FINAL INSPECTION | 10/02/2008 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 09/29/2008 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: remove dumpster right side adj. property, & pick up trash from around same area.....seed & straw all exposed earth on right adj. property.....place sod on right adj. property swale as marked, at same level as existing grade.....remove all trash from right adj. property.....46 sf road damage $468.00 | |||
| PRE DRIVEWAY | 08/15/2008 | APPROVED | DRANDALL |
| Note: Burt called to schedule this inspection for 8/15/08 | |||
| INSULATION INSPECTION | 05/27/2008 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 05/22/2008 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: PLANS INDICATE SKY-LIGHT ON BOTH SIDES OF DUPLEX, WHAT APPEARS TO BE IN IS SUN TUBE. CLARIFICATION IS NEEDED TO VERIFY INSULATION AND FRAMING NEEDED FOR TUBE OR SKY-LIGHT TO EXSTEND TO CEILING HEIGHT..........MARK 931-2912 | |||
| ALL ROUGH | 05/20/2008 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 05/15/2008 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: ON THE RIGHT SIDE, THE WIRING RUNNING PARALLEL OUT OF THE ELECTRICAL PANEL SHOULD BE STAPLED, ADD FIREBLOCKING TO BOTH SIDES IN THE TOP OF THE DOUBLE WALL CLOSETS, FRAME OUT AROUND BOTH DRYER VENTS, ADD FIREBLOCKING OVER THE LEFT SIDE AIR RETURN. THE FIRE WALL ALSO HAS TO BE CALLED IN WHEN COMPLETE, IT NEEDS TO BE TOTALLY SHEETROCKED (SOFFITS AS WELL], BLOCK TOTALLY THE PEAK VENTING AND TAPE AND MUD IT UP! ART 931 3958 | |||
| FIREWALL FRAMING (DUPLEX) | 05/13/2008 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 05/05/2008 | APPROVED | DROCKWELL |
| FIREWALL INSPECTION | 05/05/2008 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: MUST HAVETOTAL SEPARATION WITH FIRE ROCK,WRAP BRACING AS REQUESTED PREVIOUS INSPECTION.OFF-RIDGE VENT IS CENTERED ON FIRE WALL-MOVE AND REPAIR HOLE. | |||
| FIREWALL FRAMING (DUPLEX) | 05/01/2008 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: ALL WOOD MEMBERS( INCLUDING BRACING) ATTACHED TO FIREWALL TRUSS MUST BE PROTECTED WITH FIRE-RATED SHEETROCK. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/29/2008 | APPROVED - AS NOTED | DROCKWELL |
| Note: ROOF METAL INSTALLED AS REQUESTED | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/25/2008 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION CALL FOR ROOF-IN-PROGRESS BEFORE OR DURING ALL-ROUGH | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/21/2008 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: CHECK ALL TRUSS STRAPS-RE-STRAP OR PAD OUT ALL OFF-SET STRAPS/BOLT 4PLY TO PLAN/BOLT LEDGER AT TOP PLATE 6`` FROM ENDS/CHECK TRUSS ENGINEERING. | |||
| LINTEL | 04/10/2008 | APPROVED | DROCKWELL |
| LINTEL | 04/02/2008 | APPROVED | DROCKWELL |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/01/2008 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/24/2008 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 03/20/2008 | APPROVED | PGALLMANN |
| TEMPORARY POLE | 03/20/2008 | APPROVED | RMARVEL |
| Note: KC ELECTRIC |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/14/2007 | 11/16/2007 |
| Note: Released By: FREODICA Reviewed by Auba. | |||
| BLD | HOLD | 11/09/2007 | 11/13/2007 |
| Note: Held By: JJOSEPH 1. How the Openings will be protected? If the windows are not impact resistant or large missile impact; please submit hurricane shutter or corrugated metal or storm panels or plywood shutter and Florida Product Approval number. 2..Indicate how the wall separation will be rated (fire resistance)? | |||
| ZON | COMPLETE | 11/01/2007 | 11/01/2007 |
| Note: Released By: ECOYNE | |||
| SW1 | COMPLETE | 10/24/2007 | 10/25/2007 |
| Note: Released By: WKINELL Topo survey/LGP received.\\wk | |||
| PLENV | COMPLETE | 10/05/2007 | 11/19/2007 |
| Note: Released By: DBEVAN received e-mail to add Denise Brevan as reviewer on this permit | |||
| ZON | HOLD | 10/04/2007 | 10/08/2007 |
| Note: Held By: JGONZALEZ 1. need survey with setbacks, easements, and house shown on it 2. need to see all a/c and door pads on survey and relation to 5ft easement 3. landscaping needed along rear of house becuse backs up to a road 4. Need 2 additional trees on property. 1 tree for every 2,500 sqft. only 4 trees on 15,000 sqft lot. must have at least 6 trees. jgonzalez | |||
| SW1 | HOLD | 10/04/2007 | 10/04/2007 |
| Note: Held By: WKINELL No Lot Grading Plan (LGP) received. Please submit a LGP to the Stormwater Department that includes proposed elevations sufficient to demonstrate that stormwater will not flow onto adjacent properties and will be directed to the front swales. Proposed elevations of the swales and culvert pipe inverts must also be included.\\wk | |||
| ZON | HOLD | 10/31/2007 | |
| Note: Held By: ECOYNE sumnation on plans does not add up correctly. a/c pads still not on site plan | |||
| BLD | HOLD | 11/06/2007 | |
| Note: Held By: JJOSEPH 1. Please match up the area between the floor plan(1902sq.ft and1701sq.ft) and the Energy calculation sheet(1571sq.ft and 1772 sq.ft). 2. Please submit two differents copies for each side. 3. How the Openings will be protected? If the windows are not impact resistant or large missile impact; please submit hurricane shutter or corrugated metal or storm panels or plywood shutter and Florida Product Approval number. 4.Indicate how the wall separation will be rated (fire resistance)? | |||
| BLD | COMPLETE | 04/04/2008 | |
| Note: Released By: JJOSEPH |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REINSPECTION FEE | ¤40.00 | 10/30/2008 |
| REVISION | ¤40.00 | 10/30/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 10/30/2008 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤6,497.02 | 01/28/2008 |
| SCHOOL BOARD IMPACT FEE RES | ¤7,200.00 | 01/28/2008 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/28/2008 |
| ADMIN FEE | ¤20.00 | 01/28/2008 |
| ARC HOUSE REVIEW | ¤125.00 | 01/28/2008 |
| BUILDING CODE ADMIN FUND | ¤23.43 | 01/28/2008 |
| ELECTRIC FEE | ¤257.40 | 01/28/2008 |
| FIRE IMPACT FEE RES 4/1/07 | ¤370.22 | 01/28/2008 |
| MECHANICAL FEE | ¤257.40 | 01/28/2008 |
| PERMIT FEE | ¤1,478.10 | 01/28/2008 |
| PARKS IMPACT FEE 4/1/07 | ¤2,392.22 | 01/28/2008 |
| PLAN CHECK FEE | ¤151.60 | 01/28/2008 |
| PLUMBING FEE | ¤257.40 | 01/28/2008 |
| RADON FEE | ¤23.43 | 01/28/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,488.22 |