Permit #2007100299

Permit Details

Status: COED

COMMERCIAL SQUARE FOOTAGE: 1603 sqft
Total Square Footage: 1603 sqft
Block: 00000
Subdivision: -
Job Phone: (904)260-2900
Location Address: 21 HOSPITAL DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 12/12/2007
NOC: RECORDED
Applicant name: RONALD H FOSTER
Owner: PALM COAST MEDICAL SPECIALISTS,LLC

Address

595 W. GRANADA BLVD

ORMOND BEACH, FL 32174

Lot: 20
Contracted Stated Job Value: ¤150,000.00
Job Description: BUILD OUT FOR "QUEST DIAGNOSTIC" -- SUITE 265
Type: CN

Contractor

STELLAR GROUP INC
Status Location Address State License Number Phone
INACTIVE

2900 HARTLEY ROAD

JACKSONVILLE, FL 32257

CGC052029 (Exp: 08/31/2024) 904-899-9214

Sub Contractors

RONALD A AUTREY
Status Location Address State License Number Phone
CANCEL

PO Box 1799

Jacksonville, Fl., 32201

ECOOOO388 (Exp: 08/31/2018) (904) 388-8000
WILLIAM W GAY
Status Location Address State License Number Phone Fax
DECEASED

524 STOCKTON STREET

JACKSONVILLE, FL 32204

CMC008140 (Exp: 08/31/2020) (904)388-2696 904-394-7944
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
JOHN W BARBER JR
Status Location Address State License Number Phone Fax
INACTIVE

1514 BERNITA STREET

JACKSONVILLE, FL 32211

CCC057141 (Exp: 08/31/2020) (904)744-4067 (904)744-4209

Inspection History

Type Request Date Result Inspector
UTILITY COMMERCIAL FINAL 04/08/2008 APPROVED DSPENCER
FINAL COMPLETE BUILDING INSPECTION 04/08/2008 FINAL APPROVED JLEVRAULT
FIRE FINAL 04/04/2008 APPROVED JPATTEE
ELECTRICAL FINAL 03/28/2008 APPROVED RMARVEL
PLUMBING FINAL 03/27/2008 APPROVED JGIBSON
H.V.A.C. FINAL 03/25/2008 APPROVED JLEVRAULT
ABOVE CEILING 02/18/2008 APPROVED JLEVRAULT
COMMERCIAL POWER INSPECTION 02/01/2008 APPROVED LHITES
H.V.A.C. ROUGH 01/31/2008 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
FIREWALL INSPECTION 01/30/2008 APPROVED JPATTEE
2ND ROUGH ELECTRICAL 01/14/2008 APPROVED JHINDMAN
SECOND ROUGH PLUMBING INSPECTION 01/14/2008 APPROVED PGALLMANN
H.V.A.C. ROUGH 01/14/2008 Disapproved -FEE REQUIRED JLEVRAULT
Note: NOT READY.

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/31/2008 03/31/2008
Note: Released By: SKNOPF Approved for Release Revision - Panel moved
BLD COMPLETE 03/27/2008 03/27/2008
Note: Released By: FREODICA Revision: paper towel dispenser lighting layout in waiting area has been adjusted to accomodate for space availability above the ceiling.
ELEC COMPLETE 03/20/2008 03/20/2008
Note: Released By: SKNOPF Approved for Release. Revision: Various electrical changes (see electrical comments 3-14-2008). Released by L.W.
ELEC HOLD 03/11/2008 03/14/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2007100299 (Suite 265 Quest Diagnostics @ 21 Hospital Dr) 3/14/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-265: a. Circuit 38 RTU-2-13-A shows only 10KW load in panel schedule. Mechanical schedule shows 10KW for the evaporator heater alone, not including the evaporator fan. Please review and revise panel load. b. The following circuits have undersized loads in the panel schedule: 1,7,19. Please review and revise. c. Circuit 25 in panel schedule shows no load. Provide load in panel schedule. d. Provide nameplate load for the following equipment: refrigerator (9), microwave (11), refrigerator (13), copier (17). e. Provide nameplate load for BD-2-13-A. Mechanical schedule does not provide sufficient electrical data to verify load. f. Revise Load Calculation to comply with NEC 220 using actual lighting, receptacle, equipment, HVAC and largest motor loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD COMPLETE 01/22/2008 01/23/2008
Note: Released By: FREODICA Rev.- 1. Sheet P101-265: Added remote shut-off valves for drug testing rooms (2664, 2663) 2. Sheet P801-265: Revised Domestic Water Isometric.
BLD COMPLETE 12/06/2007 12/10/2007
Note: Released By: FREODICA
BLD HOLD 11/08/2007 11/21/2007
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application Number 2007100299 Architectural Comments: 1. Cover sheet: Building Code Analysis: a. Revise project Name " Tenant Build-Out For Vein Treatment Center" to Quest Diagnostics to match plans. b. On Applicable codes, revise FBC to include 2005 supplements, and update National Electrical Code from 2002 to 2005. c. On occupancy separation, referenced Table 704.1 can not be found. d. On exit lights, referenced section 1016.2 is for minimum corridor width. Mechanical Comments: 1. Sheet M001-265: Rooftop A/C Equipment Schedule: Provide data on total sensible/cooling capacity and MCA/MOCP. 2. Sheet M001-265: VAV Box Schedule: Verify if VAV-2-13-B and VAV-2-13-C can deliver the required CFM indicated on plan. The maximum CFM on those VAV is about 25% less than the required CFM. 3. Sheet M101-265: Mechanical Roof Plan Notes: Note #2 does not match with the roof plan. Plumbing Comments: 1. Sheet P801-265: Domestic Water Isometric Suite 265: a. Water heater cold/hot water piping branch take off do not match with plan. b. Cold water piping supply to lMB-1 at Break Room and at Processing Room does not match with plan. Electrical Comments: 1. Sheet E001-265: a. Electrical Drawing List shows E601 Electrical Power Single Line diagram, but this drawing was not submitted with the plans. b. Panel Schedule 265 - Circuit 30 has no KVA shown. Include KVA in revised load calculations c. Review and clarify Suite 265 load calculations for lighting, receptacles and HVAC 2. Sheet E102-265: a. Business Office 2651 shows (1) duplex receptacle. Detail 10 A201-265 shows (1) quad receptacle. b. Processing 2661 shows an isolated ground quad receptacle within 6' of the sink. This should be a GFCI receptacle. 3. Review and clarify whether this facility meets the criteria of a "Laboratory" as defined by NFPA 99 Chapter 3.3.87. If so, comply with NFPA 99 Chapter 11, and NFPA 45.
FI1 COMPLETE 10/24/2007 12/11/2007
Note: Released By: JPATTEE
UD1 COMPLETE 10/18/2007 10/23/2007
Note: Released By: CJOHNSON
DSD COMPLETE 10/17/2007 10/18/2007
Note: Released By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
ADMIN FEE ¤20.00 12/12/2007
ELECTRIC FEE ¤120.00 12/12/2007
FIRE PLANS REVIEW ¤25.00 12/12/2007
MECHANICAL FEE ¤120.00 12/12/2007
PERMIT FEE ¤1,050.00 12/12/2007
PLAN CHECK FEE ¤172.50 12/12/2007
PLUMBING FEE ¤120.00 12/12/2007
Fees Total Due: ¤0.00 Total Paid: ¤1,827.50