Permit #2007110218
Permit Details
Status: COED
| Parcel Id: 06-12-31-5815-00000-0050 |
| COMMERCIAL SQUARE FOOTAGE: 4995 sqft |
| Total Square Footage: 4995 sqft |
| Block: 00000 |
| Subdivision: 2088 - TOWN CENTER |
| Job Phone: (386)677-8736 |
| Location Address: 746 BELLE TERRE PKWY |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 01/25/2008 |
| NOC: RECORDED |
| Applicant name: LEONARD MARINACCO |
| Owner: NATIONAL CITY BANK |
|
Address 4105 9TH ST SW VERO BEACH, FL 32968 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤800,000.00 |
| Job Description: NATIONAL CITY BANK TOWN CENTER- SP-MIN-07-01 |
| Type: CN |
Contractor
BOMAR CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
27 S ORCHARD STREET ORMOND BEACH, FL 32174 |
CGC015648 (Exp: 08/31/2022) | (386)677-8736 | (386)677-7726 |
Sub Contractors
BRADLEY S GILES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 214176 S. DAYTONA, FL 32119 |
EC0001538 (Exp: 08/31/2026) | (386) 767-5895 | (386)767-6260 |
DONALD G MEYER
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Drawer 730008 Ormond Beach, FL 32174 |
CAC039739 (Exp: 08/31/2016) | (386) 253-7774 |
ISAAC WALTER JOHNSTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
887 BRENTWOOD DRIVE Daytona Beach, FL 32117 |
CFC023634 (Exp: 08/31/2026) | (386) 252-7047 |
STUART A LYONS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
2393 Bellevue Ave. Ext. DAYTONA BEACH, FL 32114 |
CCC032500 (Exp: 08/31/2024) | (386) 257-1007 | (386)257-9040 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/29/2008 | FINAL APPROVED | JHINDMAN |
| Note: requested by contractor | |||
| ENGINEERING FINAL | 05/28/2008 | APPROVED | LFITZGERALD |
| TRAFFIC ENGINEER | 05/28/2008 | APPROVED | LFITZGERALD |
| UTILITY COMMERCIAL FINAL | 05/27/2008 | APPROVED | DSPENCER |
| UTILITY COMPANY FINAL | 05/27/2008 | APPROVED | DSPENCER |
| LANDSCAPE FINAL | 05/23/2008 | APPROVED | WBUTLER |
| PLUMBING FINAL | 05/23/2008 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 05/22/2008 | APPROVED | RMARVEL |
| H.V.A.C. FINAL | 05/20/2008 | APPROVED | JLEVRAULT |
| FIRE FINAL | 05/20/2008 | APPROVED | JPATTEE |
| PLUMBING FINAL | 05/20/2008 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: MISSING 2 WALL C/O IN MENS RESTROOM ADD TOILETS NOT TO CODE WATER HEATER IS LEAKING @ T& P VALVE MAKE CORRECTIONS AND CALL BACK FOR INSPECTION.MARK 931-2912 | |||
| COMMERCIAL POWER INSPECTION | 05/12/2008 | APPROVED | RMARVEL |
| Note: GILES | |||
| FIREWALL INSPECTION | 05/07/2008 | APPROVED | JPATTEE |
| ABOVE CEILING | 05/07/2008 | APPROVED | JLEVRAULT |
| H.V.A.C. ROUGH | 05/07/2008 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 04/23/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: THIS IS A REINSPECTION requested by contractor DRIVE THRU CEILING FRAMING. | |||
| FRAMING | 04/22/2008 | CANCELLED BY APPLICANT | JLEVRAULT |
| Note: per request of contractor | |||
| H.V.A.C. ROUGH | 04/10/2008 | PARTIALLY APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION requested by contractor ALL DUCTWORK EXCEPT FOR MECHANICAL ROOMS. | |||
| INSULATION INSPECTION | 04/10/2008 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION requested by contractor | |||
| ROOF IN PROGRESS | 04/07/2008 | APPROVED | RMARVEL |
| 2ND ROUGH ELECTRICAL | 04/07/2008 | APPROVED | RMARVEL |
| LATH /BRICK FLASHING | 04/07/2008 | APPROVED | RMARVEL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/31/2008 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| 2ND ROUGH ELECTRICAL | 03/31/2008 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION OUTSIDE SOFFIT CANS MAIN BUILDING | |||
| 2ND ROUGH ELECTRICAL | 03/28/2008 | PARTIALLY APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION SEPERATION OF WATER COOLER POWER FROM BATHROOM. STRAPPING OF MC ABOVE THE PANEL. | |||
| INSULATION INSPECTION | 03/28/2008 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: PROVIDE A REVISION SHOWING NEW WALL SECTION WITH METAL STUDS AND INSULATION IN LIEU OF CORE FILLED BLOCK INSULATION. | |||
| H.V.A.C. ROUGH | 03/28/2008 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: PLANS SHOW METAL DUCT - INSUL DUCT BOARD WAS USED INSTEAD. REMOVE OR PROVIDE A REVISION. | |||
| FRAMING | 03/25/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: INTERIOR WALL FRAMING. | |||
| 2ND ROUGH ELECTRICAL | 03/25/2008 | PARTIALLY APPROVED | LHITES |
| Note: HIGHLITED ON PLANS | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/24/2008 | APPROVED - AS NOTED | CMINI |
| Note: SLABS FOR DRIVE-THRU.. | |||
| FOUNDATION SURVEY APPROVED BY ZONING | 03/24/2008 | APPROVED | JGONZALEZ |
| SECOND ROUGH PLUMBING INSPECTION | 03/20/2008 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 03/19/2008 | APPROVED | DROCKWELL |
| FOOTER | 03/19/2008 | APPROVED - AS NOTED | DROCKWELL |
| Note: DUMPSTER SLAB AND ISLAND CURBING | |||
| LINTEL | 03/19/2008 | APPROVED | DROCKWELL |
| Note: DUMPSTER LINTEL | |||
| SECOND ROUGH PLUMBING INSPECTION | 03/18/2008 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY. FLOOR DRAINS NOT SET, SEVERAL WALL AND FLOOR CLEANOUTS MISSING. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/12/2008 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION NEED TO FILL IN LOW TIE BEAM ....NEED ATTACHMENT DETAIL FOR SOFFIT TO CMUS...NEED LETTER FOR USE OF 1X4 INSTEAD OF 2X4 ON 6` O.C. BRACING ON TRUSSES.... OK TO ROOF,ENGINEERING GOOD.. CHARLIE 931-1251 | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/06/2008 | CANCELLED BY APPLICANT | JLEVRAULT |
| TEMPORARY POLE | 03/05/2008 | APPROVED | LHITES |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/22/2008 | APPROVED | CMINI |
| STEM WALL FOUNDATION | 02/22/2008 | APPROVED - AS NOTED | CMINI |
| Note: DUMPSTER PAD STEM WALL.. | |||
| FOOTER | 02/21/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: FOR DUMPSTER DUMPSTER PAD. | |||
| LINTEL | 02/21/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: Contractor called to schedule this inspection for 2/21/08 LAST LIFT - CENTER WALL AND ABOVE TIE BEAMS - HILITED AND DATED ON JOB PLANS. | |||
| COLUMN INSPECTION | 02/19/2008 | PARTIALLY APPROVED | JLEVRAULT |
| Note: requested by contractor COLUMNS AND TIE BEAMS APPROVED - HILITED AND DATED ON JOB PLANS. | |||
| LINTEL | 02/19/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: requested by contractor LAST LIFT, EXCEPT CENTER WALL AND ABOVE TIE BEAMS. | |||
| LINTEL | 02/13/2008 | APPROVED - AS NOTED | DROCKWELL |
| Note: 2ND LIFT CALLED BY LEVI HUTCHINGS OK TO ADD PER JOE MC 2ND LIFT | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/13/2008 | APPROVED | JGIBSON |
| LINTEL | 02/11/2008 | APPROVED - AS NOTED | DROCKWELL |
| Note: per Joe McGowen I was given permission to lower priority code 1ST LIFT O.K | |||
| TIE BEAM | 02/06/2008 | APPROVED | DROCKWELL |
| FOOTER | 02/04/2008 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION PER CONTRACTOR REQUEST | |||
| FOOTER | 01/31/2008 | Disapproved -FEE REQUIRED | CMINI |
| Note: requested by contractor APPROVED PLAN DOES NOT MATCH WORK ON JOB NEED REVISION OR CORRECTION. CHARLIE 931-1251 | |||
| ELECTRIC FEEDER | 01/31/2008 | APPROVED | LHITES |
| Note: requested by contractor UNDERGROUND FEEDER TO TRANSFORMER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/21/2008 | 04/21/2008 |
| Note: Released By: FREODICA Revision Drive thru ceiling framing detail sheet. | |||
| BLD | COMPLETE | 04/07/2008 | 04/09/2008 |
| Note: Released By: JMCGOWEN AS BUILT ELETRICAL DRAWINGS AMD EXTERIOR WALL FRAMING/INSULATION | |||
| ELEC | COMPLETE | 04/07/2008 | 04/09/2008 |
| Note: Released By: JMCGOWEN as built and revision as per plan review comments. | |||
| ELEC | HOLD | 02/19/2008 | 02/19/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2007110218 (National City Bank @ 746 Belle Terre Pkwy) 2/19/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Sheet E-311 Power Riser Diagram: a. Both Notes 9 & 10 in Riser Notes on line and load side of 100A disconnect for Panel 'C' require four (4) conductors and an equipment ground. Only 3 conductors shown for both feeders. Review and revise. b. Provide physical location on Sheet E111 where 100A disconnect for Panel 'C' will be located. c. Comply with NEC 240.21 Tap Rules for Note 9 feeder. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 02/18/2008 | 02/20/2008 |
| Note: Released By: FREODICA Rev.- Architectural, structural, Mech & electrical. See listing. Note: All submitted electrical sheets are on hold. | |||
| BLD | COMPLETE | 01/18/2008 | 01/18/2008 |
| Note: Released By: FREODICA | |||
| FI1 | COMPLETE | 12/20/2007 | 12/20/2007 |
| Note: Released By: JPATTEE | |||
| BLD | HOLD | 11/14/2007 | 12/14/2007 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2007110218 (746 Belle Terre Pkwy) 12/14/2007 The following items must be resolved in order to complete the Building Permit plan review. Architectural Comments: 1. Revise design codes to indicate 2004 Florida Building, Plumbing and Mechanical Code(s) with 2007 revisions and the 2005 National Electrical Code. 2. Revise cover sheet "New Building and Construction Data" Occupancy Classification to indicate Mixed (Separated). 3. Building Construction type is shown as Type II B Unprotected Non-sprinklered but numerous plan details indicate pre-engineered wood trusses with plywood decking (shown as ½" in detail and 5/8" in sheathing note on sheet S-103), which is not permitted, by code, for Type II B construction. Revise accordingly. 4. An Accessory Assembly Area (conference room 120) greater than 750 sq ft must be separated from other occupancies by at least 1 hour fire resistant construction per FBC, sections 302.1.1 and 302.2.1. 5. Provide detail(s) which indicate the method(s) of extending from the top of the wall to the roof deck, the rated walls (types 2 and 3), which enclose the conference room. 6. Provide labeled a door, door frame and the appropriate hardware for the door opening in the rated wall assembly between the conference room and corridor 123. 7. Provide separation of the exit doors, from conference room 120, equal to at least half the diagonal measurement of that space 8. Conference room 120 has a calculated occupant load of 55 persons (811 sq ft / 15 sq per person = 54.06). Given that there are two exits from the conference room, each exit would serve half of that occupant load, which would imply that the exit into the corridor (marked 123) would serve 28 persons from the conference room and that corridor would also serve 4 additional persons form office spaces 121 and 122 for a total of 32 persons. That being said, a corridor, in a non-sprinklered business occupancy, serving an occupant load greater than 30 must have a 1 hour fire resistance rating per FBC, Table 1016.1. Provide at least 1 hour fire resistant construction for the full length of the corridor marked 123 with equivalent protection for all openings in assemblies of rated construction. 9. Provide UL Listing Number and installation detail(s) for methods of protecting through penetrations of rated assemblies. 10. Provide signs or stencils, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS", on walls of rated construction, above decorative ceilings and in other concealed spaces. 11. Provide maneuvering space(s) on the pull side of the rest room doors per FBC, Chapter 11, figure 25, as applicable. Mechanical Comment: 1. Sheet M101: Additional fire dampers would be required for all ducts penetrating fire rated walls as mentioned in Architectural Comment #8 above. Plumbing Comments: 1. Sheet P101: Water Floor Plan: a. The location of cold water line going into the building does not match with the location shown on site plan. Please revise plan and water riser to match each other. b. The cold water line entering the building has a note that indicates 1-1/2" CW up above ceiling but the water riser shows below grade on sheet P401. Please clarify. Electrical Comments: 1. Sheet E002: Pole Detail shows minimum windload of 110mph. Please revise to 120 mph minimum windload this area. 2. Sheet E311: Power Riser Diagram a. Note 2 Feeder from CT to Service Disconnect indicates a #1/0 ground. Please revise Riser to conform to NEC 250. b. Note 4 indicates #3 grounding electrode conductor. Revise grounding electrode conductor to comply with NEC Table 250.66. c. Optional Standby Generator: 1) Manual Transfer Switch cannot be placed on the load side of the panel it is serving. When Generator is running, this will create backfeeding of power through any closed ("on") circuit breakers. Please revise Power Riser. 2) Provide identification of circuit breakers and load calculations for all loads that Generator will be sustaining. 3) You may reference the 2008 NEC at www.nfpa.org/aboutthecodes/AboutTheCodes.asp?DocNum=70 for further clarification of the intent of NEC Art. 702.5 where it relates to Manual Transfer Switches and Optional Standby Generators. Larry Woodrome, CBO Building Official 386-986-3786 | |||
| FI1 | HOLD | 12/05/2007 | |
| Note: Held By: JPATTEE 1) Unable to locate exit lighting on sheet E211. | |||
| BLD | COMPLETE | 03/26/2008 | |
| Note: Released By: JJOSEPH |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/21/2008 |
| REVISION | ¤40.00 | 04/21/2008 |
| REINSPECTION FEE | ¤40.00 | 04/09/2008 |
| REINSPECTION FEE | ¤40.00 | 04/09/2008 |
| REVISION | ¤60.00 | 04/09/2008 |
| REVISION | ¤40.00 | 03/28/2008 |
| REINSPECTION FEE | ¤40.00 | 03/18/2008 |
| REINSPECTION FEE | ¤40.00 | 03/18/2008 |
| REVISION | ¤80.00 | 02/21/2008 |
| REINSPECTION FEE | ¤40.00 | 02/01/2008 |
| TRANSPORTATION IMPACT FEE | ¤112,104.93 | 01/25/2008 |
| ADMIN FEE | ¤20.00 | 01/25/2008 |
| BUILDING CODE ADMIN FUND | ¤24.98 | 01/25/2008 |
| ELECTRIC FEE | ¤510.00 | 01/25/2008 |
| FIRE COMM IMPACT FEE 4/1/07 | ¤256.24 | 01/25/2008 |
| FIRE PLANS REVIEW | ¤49.95 | 01/25/2008 |
| MECHANICAL FEE | ¤510.00 | 01/25/2008 |
| PERMIT FEE | ¤4,400.00 | 01/25/2008 |
| PLAN CHECK FEE | ¤920.00 | 01/25/2008 |
| PLUMBING FEE | ¤510.00 | 01/25/2008 |
| RADON FEE | ¤24.98 | 01/25/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤119,791.08 |