Permit #2007110405

Permit Details

Status: FINAL

Parcel Id: 20-10-30-0000-01020-0000
Block: 01020
Subdivision: 2135 - SAWMILL CREEK SUBDIVISION
Job Phone: (407)467-5271
Location Address: 11 SWEETBAY CT
Type: EL - ELECTRICAL
Issue Date: 04/01/2008
NOC: Unknown
Applicant name: MICHAEL MCRAE DEESE
Owner: PALM COAST FOREST LLC

Address

SUITE 3A

PALM COAST, FL 32137

Address

1 CORPORATE DRIVE

PALM COAST, FL 32137

Lot: 0000
Contracted Stated Job Value: ¤2,350.00
Job Description: INSTALL RACK DISCONNECTS, METER CAN, CONTROL PANEL & WIRE PUMPS - WELLFIELDS # SW-126
Type: CN

Contractor

ALL FLORIDA POWER SYSTEMS INC.
Status Location Address State License Number Phone Fax
CANCEL

734 PATE ROGERS ROAD

POMPANO BEACH, FL 33060

EC0001688 (Exp: 09/30/2008) (407)467-5271 (386)774-9687

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 04/07/2008 FINAL APPROVED RMARVEL

Review History

Department Status Date In Date Out
BLD COMPLETE 01/18/2008 01/22/2008
Note: Released By: SKNOPF Approved for Release
BLD HOLD 11/28/2007 12/04/2007
Note: Held By: SKNOPF Electrical Comments: 1. Sheet E-05: a. Revise Single Line Diagram to reflect SW-126 and it's 75HP future brackish well pump. b. Provide bonding per NEC 250. c. Clarify equipment grounding conductor for feeders: 1) 225A Disconnect to ATS 2) Generator to ATS d. Please include 3KVA transformer load in load calculations e. Revise Load Calculations to reflect SW-126. f. Well Designations table reflects SW126 as 25HP pump. Sheet E-22 shows pump as 20HP. Please coordinate drawings. 2. Sheets E-05 and E-22: Provide grounding and bonding requirements for generator including grounding electrode conductor size, grounding electrode requirements per NEC. 3. Sheet E-22: Provide grounding electrode requirements, ie; quantity, diameter and length per NEC. 4. Sheet E-23: a. Revise circuit L1-6 to include 180VA for each receptacle on each pole. Revise load calculations. 5. Sheet E-24: a. Detail 1 - Provide size of copper grounding conductor for gate or fence post grounding. b. Detail 2 - Provide grounding requirements for aluminum light poles per NEC. c. Detail 3 - Provide size of copper grounding conductor for RTU Antenna & Mast Installation. 6. 8-1/2" x 11" attached Riser a. 8-1/2" x 11" attached Riser does not match single Line Diagram Sheet E-05 for sequence of feeders and grounding requirements. Please coordinate these drawings. b. Riser this sheet has power source entering Service disconnect before Meter. Power source must pass thru Meter first. c. Riser this sheet shows Service ground developed at the Meter. Meter enclosure can be bonded, but Service ground is developed at the first means of disconnect, which would be the Service Disconnect. Please revise.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ELECTRIC FEE ¤31.41 04/01/2008
Fees Total Due: ¤0.00 Total Paid: ¤31.41