Permit #2007110405
Permit Details
Status: FINAL
| Parcel Id: 20-10-30-0000-01020-0000 |
| Block: 01020 |
| Subdivision: 2135 - SAWMILL CREEK SUBDIVISION |
| Job Phone: (407)467-5271 |
| Location Address: 11 SWEETBAY CT |
| Type: EL - ELECTRICAL |
| Issue Date: 04/01/2008 |
| NOC: Unknown |
| Applicant name: MICHAEL MCRAE DEESE |
| Owner: PALM COAST FOREST LLC |
|
Address SUITE 3A PALM COAST, FL 32137 |
|
Address 1 CORPORATE DRIVE PALM COAST, FL 32137 |
| Lot: 0000 |
| Contracted Stated Job Value: ¤2,350.00 |
| Job Description: INSTALL RACK DISCONNECTS, METER CAN, CONTROL PANEL & WIRE PUMPS - WELLFIELDS # SW-126 |
| Type: CN |
Contractor
ALL FLORIDA POWER SYSTEMS INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
734 PATE ROGERS ROAD POMPANO BEACH, FL 33060 |
EC0001688 (Exp: 09/30/2008) | (407)467-5271 | (386)774-9687 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRICAL FINAL | 04/07/2008 | FINAL APPROVED | RMARVEL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/18/2008 | 01/22/2008 |
| Note: Released By: SKNOPF Approved for Release | |||
| BLD | HOLD | 11/28/2007 | 12/04/2007 |
| Note: Held By: SKNOPF Electrical Comments: 1. Sheet E-05: a. Revise Single Line Diagram to reflect SW-126 and it's 75HP future brackish well pump. b. Provide bonding per NEC 250. c. Clarify equipment grounding conductor for feeders: 1) 225A Disconnect to ATS 2) Generator to ATS d. Please include 3KVA transformer load in load calculations e. Revise Load Calculations to reflect SW-126. f. Well Designations table reflects SW126 as 25HP pump. Sheet E-22 shows pump as 20HP. Please coordinate drawings. 2. Sheets E-05 and E-22: Provide grounding and bonding requirements for generator including grounding electrode conductor size, grounding electrode requirements per NEC. 3. Sheet E-22: Provide grounding electrode requirements, ie; quantity, diameter and length per NEC. 4. Sheet E-23: a. Revise circuit L1-6 to include 180VA for each receptacle on each pole. Revise load calculations. 5. Sheet E-24: a. Detail 1 - Provide size of copper grounding conductor for gate or fence post grounding. b. Detail 2 - Provide grounding requirements for aluminum light poles per NEC. c. Detail 3 - Provide size of copper grounding conductor for RTU Antenna & Mast Installation. 6. 8-1/2" x 11" attached Riser a. 8-1/2" x 11" attached Riser does not match single Line Diagram Sheet E-05 for sequence of feeders and grounding requirements. Please coordinate these drawings. b. Riser this sheet has power source entering Service disconnect before Meter. Power source must pass thru Meter first. c. Riser this sheet shows Service ground developed at the Meter. Meter enclosure can be bonded, but Service ground is developed at the first means of disconnect, which would be the Service Disconnect. Please revise. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ELECTRIC FEE | ¤31.41 | 04/01/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤31.41 |