I want to search for...
Permit #2007120129
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00490-0050 |
| CONDITIONED SPACE: 1980 sqft |
| OPENED PORCH (WITH ROOF) : 297 sqft |
| OPENED PORCH (WITH ROOF) : 64 sqft |
| GARAGE: 583 sqft |
| Total Square Footage: 2924 sqft |
| Block: 00490 |
| Subdivision: - |
| Job Phone: (386) 437-2800 |
| Location Address: 167 FRONTIER DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/15/2008 |
| NOC: RECORDED |
| Applicant name: JOHN E RAWLINS |
| Owner: MCLAUGHLIN, PAUL D |
|
Address 8 CEDARVIEW COURT PALM COAST, FL 32137 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤175,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
JOHN RAWLINS CONST.INC DBA ELITE HOMES OF FLAGLER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 1583 Bunnell, FL 32110 |
CRC021225 (Exp: 08/31/2026) | (386) 437-2800 | (386)437-2314 |
Sub Contractors
JOPSEH GARDNER
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO Box 762 , FL 32110 |
EC13003038 (Exp: 09/30/2008) | (386) 672-0640 |
THOMAS ALAN MOSE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1894 HOLLY HILL, FL 32117 |
CAC048082 (Exp: 08/31/2026) | 386-255-4545 | (386)252-4979 |
ALFERD MITCHUM FUTCH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1218 San Jose Blvd Holly Hill, FL 32117 |
CFC044175 (Exp: 08/31/2012) | (386) 672-3576 | (386)672-0107 |
EUGENIA MAY MILHOLEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 2088 Bunnell, FL 32110 |
CCC048174 (Exp: 08/31/2010) | (386) 437-6457 | (386)437-6457 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/09/2008 | FINAL APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 07/08/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: plans call for 1/4" lag based screws 16" on center for hurricane panels | |||
| STORMWATER FINAL INSPECTION | 07/03/2008 | APPROVED | DRANDALL |
| Note: no inspection done, lot already cleared with dirt on site. no road damage noted | |||
| UTILITY COMPANY FINAL | 07/01/2008 | APPROVED | TSCHWEERS |
| RESIDENTIAL EARLY POWER | 06/04/2008 | APPROVED | RMARVEL |
| Note: requested by contractor FARMCO | |||
| PRE DRIVEWAY | 05/08/2008 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 05/06/2008 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: road needs to be cut at a 90 degree angle...not 45 | |||
| INSULATION INSPECTION | 04/11/2008 | APPROVED | DROCKWELL |
| ALL ROUGH | 04/09/2008 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 04/08/2008 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION NEED APPROVED NAIL PLATE FOR DRYER DUCT AT TOP PLATE.NEED APPROVED NAIL PLATE FOR KITCHEN EXHAUST DUCT ON BEDROOM SIDE.CHECK WIRING AT TOP PLATE IN LAUNDRY ROOM FOR NAIL PLATES.ALL ITEMS WERE POINTED OUT AT LAST INSPECTION TO BOTH PARTIES PRESENT WHO WALKED THROUGH WITH ME. | |||
| ALL ROUGH | 04/04/2008 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: SUPPORT WIRING WHERE IDENTIFIED/NAIL PLATES IN MASTER ALONG TOP PLATE/NAIL PLATE FOR DRYER DUCT AND KITCHEN EXHAUST.CHECK 2 GANG SWITCH BACK WALL FOR BOX FILL. | |||
| LATH /BRICK FLASHING | 03/31/2008 | APPROVED | DROCKWELL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/24/2008 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/20/2008 | Disapproved -FEE REQUIRED | CMINI |
| Note: 1. MISSING VALLEY AND RIDGE STRAPS... 2. MISSING STRAPS ON TRUSS JACKS J7A AND GO1...3 NEED TO HAVE ANCHOR BOLTS ON GARAGE WALL AT 24" O.C. 4... H-03 CALLS FOR 2 HETA 20S ON EACH END.. 5 BLOCK OUT OFF SET STRAPS ON TRUSS H-07 IF LESS THAN 1-1/2".... 6. TRUSSES AT FRONT ENTRY NOT 24" O.C. NEED TO GROUT UNDER TRUSS S-02 WHERE NOT SITTING ON FULL BEARING.. NOT READY.CHARLIE 931-1251 | |||
| LINTEL | 02/13/2008 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 02/12/2008 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: BATH VENT NOT ATTACHED INSIDE WALL. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/11/2008 | APPROVED | LAPTEKAR |
| FOUNDATION SURVEY APPROVED BY ZONING | 02/11/2008 | APPROVED | BBARTON |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/29/2008 | APPROVED | CMINI |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/28/2008 | CANCELLED BY APPLICANT | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 01/24/2008 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 01/22/2008 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: NO WATER IN STACK. POSSIBLE LEAK. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/03/2008 | 03/03/2008 |
| Note: Released By: JMCGOWEN change back porch trusses to a flat ceiling no valt | |||
| BLD | COMPLETE | 02/11/2008 | 02/11/2008 |
| Note: Released By: JJOSEPH | |||
| BLD | COMPLETE | 01/07/2008 | 01/08/2008 |
| Note: Released By: FREODICA Reviewed by Auba. | |||
| BLD | HOLD | 12/28/2007 | 01/02/2008 |
| Note: Held By: JJOSEPH Need toprovide protection for windows, such as: Hurricane shutter or storm panel or corrugated metal or plywood shutte and Florida Product Approval number, because of the windows are not impact resistant. | |||
| ZON | COMPLETE | 12/28/2007 | 12/28/2007 |
| Note: Released By: ECOYNE changed roof lines added shutters | |||
| SW1 | COMPLETE | 12/11/2007 | 12/11/2007 |
| Note: Released By: WKINELL Watch right side, rear, may drain to Lot 4??????\\wk | |||
| ZON | HOLD | 12/11/2007 | 12/12/2007 |
| Note: Held By: ECOYNE Same Model on Lot 4 171 Frontier. Suggest changing elevation/doors/windows | |||
| BLD | HOLD | 01/04/2008 | |
| Note: Held By: JJOSEPH Please revise the energy calculation to conform to the floor plan. ( Energy calculation indicates 3 bedrooms whereas the floor plan shows 4 bedrooms) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 07/14/2008 |
| REINSPECTION FEE | ¤40.00 | 07/14/2008 |
| REINSPECTION FEE | ¤40.00 | 07/14/2008 |
| REINSPECTION FEE | ¤40.00 | 07/14/2008 |
| REINSPECTION FEE | ¤40.00 | 07/14/2008 |
| REINSPECTION FEE | ¤40.00 | 07/14/2008 |
| REINSPECTION FEE | ¤40.00 | 07/14/2008 |
| REVISION | ¤40.00 | 07/14/2008 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 07/14/2008 |
| TRANS IMPACT FEE 6 - RESIDENTI | ¤3,841.11 | 01/15/2008 |
| ADMIN FEE | ¤20.00 | 01/15/2008 |
| ARC HOUSE REVIEW | ¤125.00 | 01/15/2008 |
| BUILDING CODE ADMIN FUND | ¤14.62 | 01/15/2008 |
| ELECTRIC FEE | ¤163.20 | 01/15/2008 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/15/2008 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/15/2008 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 01/15/2008 |
| MECHANICAL FEE | ¤163.20 | 01/15/2008 |
| PERMIT FEE | ¤865.80 | 01/15/2008 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 01/15/2008 |
| PLAN CHECK FEE | ¤88.80 | 01/15/2008 |
| PLUMBING FEE | ¤163.20 | 01/15/2008 |
| RADON FEE | ¤14.62 | 01/15/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,875.77 |