Permit #2008040181
Permit Details
Status: COED
| Parcel Id: 31-12-31-5371-00000-0040 |
| CONDITIONED SPACE: 5881 sqft |
| OPENED PORCH (WITH ROOF) : 2501 sqft |
| Total Square Footage: 8382 sqft |
| Block: 00000 |
| Subdivision: 2138 - SEMINOLE POINTE SUBDIVISION |
| Job Phone: 386-586-2806 |
| Location Address: 1000 INTEGRA WOODS BLVD |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 08/15/2008 |
| NOC: RECORDED |
| Applicant name: JAMES G PYLE |
| Owner: PALM COAST SEMINOLE GROUP LLC 1 FLORIDA PARK DRIVE |
|
Address #307 PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤349,841.00 |
| Job Description: LEASING CENTER- TYPE 4 (1 FLOOR, OFFICE & GYM, TANNING ROOM, THEATER, MEETING AREAS) |
| Type: CN |
Contractor
LANDSOUTH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1680 THE GREENS WAY JACKSONVILLE , FL 32277 |
CBC035104 (Exp: 08/31/2010) | 386-586-0781 | 386-586-2805 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
NINO JOE PARRALES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6824 PHILLIPS PKWY DR. S JACKSONVILLE , FL 32256 |
CAC057164 (Exp: 08/31/2010) | (904)346-1774 | (904)346-4788 |
STEPHEN JOHN CHASTAIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1923 TAMPA EAST BLVD TAMPA, FL 33619 |
CFC024520 (Exp: 08/31/2012) | (813)246-5341 | (813)246-5345 |
FRED M POMAR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1025 6TH STREET DAYTONA BEACH, FL 32117 |
CCC1328140 (Exp: 08/31/2010) | (386)255-6113 | (386)254-8816 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRICAL FINAL | 02/27/2009 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL BUILDING FINAL | 02/27/2009 | FINAL APPROVED | LWOODROME |
| Note: Approval based on previous inspection | |||
| LANDSCAPE FINAL | 02/26/2009 | APPROVED - AS NOTED | WBUTLER |
| Note: A performance bond was received in the amount of $186,585.70 to cover the unfinished landscaping and irrigation. | |||
| LANDSCAPE FINAL | 02/26/2009 | CANCELLED BY INSPECTOR | WBUTLER |
| UTILITY COMMERCIAL FINAL | 02/25/2009 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 02/25/2009 | APPROVED | KKING |
| ENGINEERING FINAL | 02/25/2009 | APPROVED | MCOBB |
| Note: per Don S. | |||
| TRAFFIC ENGINEER | 02/25/2009 | APPROVED | MCOBB |
| Note: per Don S. | |||
| H.V.A.C. FINAL | 02/20/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 2/19/2009 4:57:37 PM AFTERNOON REQUESTED | |||
| FIRE FINAL | 02/19/2009 | APPROVED | JPATTEE |
| COMMERCIAL BUILDING FINAL | 02/10/2009 | APPROVED | JHINDMAN |
| Note: Inspection Resulted at 2/10/2009 3:26:02 PM FINAL OK BUT CANNOT 99 UNTIL OTHER INSPECTIONS HAVE PASSED | |||
| H.V.A.C. FINAL | 02/10/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/10/2009 3:14:47 PM REGISTER SIZES IN SEVERAL ROOMS DOES NOT MATCH PLANS. TEST AND BALANCE REPORT MUST BE SIGNED AND SEALED AND ALSO NEEDS TO BE LEGIBLE. | |||
| ELECTRICAL FINAL | 02/06/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 2/6/2009 3:07:55 PM EXISTING ELECTRICAL NEEDS TO MATCH APPROVED SET OF PLANS. DO AS BUILTS FOR PANELS NEED REVISED LOAD CALCS DUE TO ADDED RECEPTACLES THROUGH OUT BUILDING. | |||
| H.V.A.C. FINAL | 02/04/2009 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: Inspection Resulted at 2/4/2009 3:37:07 PM BY DAVE | |||
| PLUMBING FINAL | 02/04/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 01/22/2009 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: Inspection Requested at 1/21/2009 4:35:28 PM PARTIAL ONLY FOR SEWER TIE IN | |||
| COMMERCIAL POWER INSPECTION | 01/13/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL POWER INSPECTION | 01/09/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: requested by contractor Inspection Resulted at 1/9/2009 3:19:15 PM PROPERLY TORQUE LUGS IN PANELS. BOND NEUTRAL TO GROUND AT FIRST MEANS OF DISCONNECT. | |||
| TIE DOWN | 11/12/2008 | APPROVED | BBEMBRY |
| Note: letter submitted from engineer regarding the quick tie cables | |||
| LATH /BRICK FLASHING | 11/10/2008 | APPROVED | JHINDMAN |
| INSULATION INSPECTION | 10/24/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 10/20/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION REQUESTED BY DAVE Inspection Resulted at 10/20/2008 3:28:20 PM DRAFTSTOP NOT COMPLETE ON TRUSS ABOVE REC ROOM, FIRESTOPS MISSING IN SEVERAL PLACES. | |||
| INSULATION INSPECTION | 10/14/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 10/14/2008 3:15:49 PM FIRESTOP ALL CHASES AND FIREBLOCKS | |||
| FRAMING | 10/13/2008 | APPROVED | JHINDMAN |
| FOUNDATION SURVEY APPROVED BY ZONING | 10/13/2008 | APPROVED | DRAMIREZ |
| SECOND ROUGH PLUMBING INSPECTION | 10/10/2008 | APPROVED | JMCGOWEN |
| H.V.A.C. ROUGH | 10/10/2008 | APPROVED | JMCGOWEN |
| 2ND ROUGH ELECTRICAL | 10/09/2008 | APPROVED | RMARVEL |
| Note: requested by contracotor | |||
| ROOF IN PROGRESS | 09/30/2008 | APPROVED | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/25/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 09/24/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/24/2008 1:51:30 PM CHECKED ANCHORS ON PORCHES | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/19/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 9/19/2008 1:41:40 PM NEED REVISION FOR QUICK TIE SYSTEM,NEED REVISION FOR TOWER WALL ANCHORAGE, NEED APPROVED TRUSS REPAIR LETTERS FOR LOOSE GUSSET PLATES ON RC23 RC31 RC41, BRACE MISSING RC63, RESTRAIN CLB BRACING PER ENGINEERING, ROOF SHEATHING OK. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 09/10/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: lower 8 foot of walls |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 02/26/2009 | 02/26/2009 |
| Note: Released By: JMCGOWEN Revision clubhouse electrical power and lighting | |||
| ELEC | COMPLETE | 02/24/2009 | 02/25/2009 |
| Note: Released By: JMCGOWEN Revision site light | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN Revision adding receptacles/ change light fixtures/ update panel schedule | |||
| MECH | CANCEL | 02/18/2009 | |
| Note: Revision 1. HVAC REVISION PLANS. SEE SHEET ME1.41 REV. 11 DATED 2-17-09. | |||
| PLUM | COMPLETE | 02/02/2009 | 02/02/2009 |
| Note: Released By: FREODICA Revision: 1. Revision 7 dated 11-26-08, sheets P1.41, P6.01, P 6.02, P6.03. | |||
| ELEC | HOLD | 01/30/2009 | 01/30/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Integra Woods #2008040172, 2008040174, 2008040177, 2008040181, 2008040182, 2008040183, 2008040184, 2008040185, 2008040186, 2008040187, 2008040188, 2008040189, 2008040190, 2008040191, 2008040192, 2008040193, 2008040194, 2008040195, 2008040198, 2008040200, 2008040202, 2008040203, 2008040204, 2008040205 1/30/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. This plan sheet shows circuits P-1, 2, 3, 4 and 6 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. b. This plan sheet shows circuit TC-2 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. c. A total of 4000W of fixture load is shown on a 1P20A circuit breaker on circuit HP3-10. Panel schedule shows an 1100W total load for both HP3-10 and HP3-11. Revise. d. A total of 3900W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-20. Panel schedule shows a 2800W total load for 3 circuits, HP1-20, 22, and 24. Revise. e. A total of 2700W of fixture load is shown on a 1P20A circuit breaker on circuit HP2-17. Revise. f. A total of 4100W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-22. Revise. g. Circuit HP2-17 thru 19 is shown as Bldg/Site lights in panel schedule, but HP2-19 does not appear on E1.01 Site Plan. Coordinate. 2. E1.91: a. Compactor Power Riser Diagram shows #6 grounding electrode conductor for a #250 Aluminum service feeder. Revise grounding electrode conductor on this sheet per NEC Table 250.66 and Grounding Electrode Table on Sheet E6.02. b. Identify HP for garage door opener circuit S-3 and GP-1, 2. Panel shows load is only 500W per motor, which would make motor smaller than 1/4HP. Confirm HP size for motor and provide load in panel schedule per NEC Table 430.248. c. Mail Kiosk Detail 1 does not identify circuit number or which Clubhouse Panel the Mail Kiosk lighting is fed from. E6.01 Clubhouse panel schedules also do not reflect Mail Kiosk lighting. Revise. d. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L1E is 2P60A on circuit C1-2:4. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. e. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L2I is 2P60A on circuit C1-6:8. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. f. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L3 is 2P60A with a 5.7KVA load on circuit C1-10:12. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. g. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L5 is 2P60A with a 5.7KVA load on circuit C2-6:8. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. h. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L4 is 2P60A on circuit C2-35:37. Panel Schedule on E6.01 has a 2P50A circuit breaker for this unit. Resolve conflict. i. Equipment Schedule ME1.43 still shows HVAC unit PTHP1 on a 2P60A circuit breaker on C2-2:4. Panel schedule C2 now shows this circuit as blank. If PTHP1 is no longer an HVAC unit on this building, delete unit from equipment schedule and submit revised drawings. Resolve conflict. j. Revise loads for circuit GP-3, 4 which are undersized in panel schedule. 3. E6.01 and E1.01: Clarify how (1) 2P40A circuit breaker on circuit HP1-16:18 is protecting feeders to (2) MLO sub-panels, "GP" and "S", in accordance with NEC 240.21(B)(5). 4. E6.02: a. Clubhouse Service Calculation - revise loads for panels in load calculation to match Demand Loads calculated in Panel Schedules on Sheet E6.01. b. Indicate which House Panel is associated with each Load Calculation for Meter Centers A & B, Bldg. Types 1, 2, and 3. Also indicate building number where each Meter Center is located. c. Revise Demand Load Calculations for Meter Centers A & B, Buildings 1, 2, and 3 to reflect Demand Load, not Connected Loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| PLLA | COMPLETE | 01/21/2009 | 01/22/2009 |
| Note: Released By: WBUTLER | |||
| ELEC | HOLD | 01/21/2009 | 01/21/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008040181 (Integra Woods Leasing Center Type 4 @ 1000 Integra Woods Blvd.) 1/21/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. Information on Sheet E1.01 regarding Electrical service feeders from FPL transformers has been deleted from this plan sheet. Reinsert this information back on this sheet. b. Identify panel circuits on plan sheet and provide revised House panel schedules with updated load calculations. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | CANCEL | 12/12/2008 | 12/15/2008 |
| Note: Contractor took out all submitted revisions (GE appliances cut sheets) for clarification- to be resubmitted later. | |||
| ZON | CANCEL | 11/19/2008 | |
| BLD | CANCEL | 11/18/2008 | 01/22/2009 |
| Note: Revision Elevations of slab | |||
| BLD | COMPLETE | 10/23/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH Revision Roofing submittals | |||
| PLUM | HOLD | 10/22/2008 | 10/23/2008 |
| Note: Held By: FREODICA Revision: 1. Submitted (2) sets of plumbing plans shall be signed and sealed by FL. Registered Engineer. | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION code compliant Hardware | |||
| BLD | COMPLETE | 09/23/2008 | 09/23/2008 |
| Note: Released By: JJOSEPH | |||
| BLD | COMPLETE | 09/22/2008 | 09/22/2008 |
| Note: Released By: JMONTARULI Released by: J Joseph Anchor placement plans that show anchor spacing for all bearing walls | |||
| BLD | COMPLETE | 09/19/2008 | 09/22/2008 |
| Note: Released By: JJOSEPH Anchor placement plans that show anchor spacing for all bearing walls REVISION attachment of a ledger to trusses | |||
| ELEC | COMPLETE | 08/04/2008 | 08/04/2008 |
| Note: Released By: SKNOPF Approved for Release. | |||
| FI1 | COMPLETE | 08/01/2008 | 08/01/2008 |
| Note: Released By: JPATTEE | |||
| ELEC | HOLD | 07/30/2008 | 08/01/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008040181 (Leasing Office Integra Woods @ 1000 Integra Woods Blvd) 8/1/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. ME1.42 & E6.02: Feeder to Panel C2 was revised to "F28" on Power Riser sheet ME1.42. Feeder Schedule E6.02 does not list this feeder identification. Identify new feeder size. 2. Service Demand Load Calculation was not given. Provide Service Demand Load Calculation for verification of Feeder "F46" from Utility Transformer. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| ELEC | HOLD | 07/23/2008 | 07/23/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008040181 (Leasing Office for Integra Woods) 7/23/2008 The following items must be resolved in order to complete the Building Permit plan review. No corrections were made to the previous July 2, 2008 COPC comments as listed below. Electrical Comments: 1. ME1.42: a. The following new Fixture types have been added to the Lighting Plans, but do not appear in the Fixture Schedule or require fixture loads in the Fixture Schedule: 1) Type 'CP', 'CJ', 'CK1', 'CR', 'CN' b. No apparent lighting controls are shown on this sheet for circuits C2-11 and C1-14. 2. ME1.43: AHU-L4 and CU-L4 were added to the Power Plan and Panel Schedule, but a revised Mechanical Schedule for these units was not submitted. Provide revised Mechanical Schedule showing these units. 3. E6.01: a. The following circuits now have undersized loads in the panel schedules: 1) C1-14, 18, 20, 23, 29, 37 2) C2-13, 15, 19, 24 b. Circuit C1-34 has 2 duplex receptacles plus a refrigerator on this circuit, but is only showing a total load of 600VA in the panel schedule. Please update panel schedule load. c. Revised calculated load for C2 shows 54.75KVA yielding 228A. Panel is sized as a 225A panel with a 200A feeder, and a 200A disconnect. Please review and revise. d. When loads are updated from Comment 3.a.1 above, the calculated demand load for C1 may exceed the disconnect size and the feeder size shown. Please review and revise as necessary. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 07/23/2008 | 07/23/2008 |
| Note: Released By: FREODICA Revision: Architectural and Structural drawings: (Revision 1) 1. Revised sheets A0.41, A0.42, A4.41, A7.01, 7.02, A7.31, A7.51, S1.40, S1.41, SDT-2, SDT-5. | |||
| PLUM | COMPLETE | 07/23/2008 | 07/23/2008 |
| Note: Released By: FREODICA revision 1. Deleted fountain (see revision 1) | |||
| MECH | COMPLETE | 07/22/2008 | 07/23/2008 |
| Note: Released By: FREODICA Revision: Relocated AHU-L4 and revised ductwork (see revision 1) | |||
| ELEC | HOLD | 07/02/2008 | 07/02/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008040181 (Leasing Office for Integra Woods) 7/2/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. ME1.42: a. The following new Fixture types have been added to the Lighting Plans, but do not appear in the Fixture Schedule or require fixture loads in the Fixture Schedule: 1) Type 'CP', 'CJ', 'CK1', 'CR', 'CN' b. No apparent lighting controls are shown on this sheet for circuits C2-11 and C1-14. 2. ME1.43: AHU-L4 and CU-L4 were added to the Power Plan and Panel Schedule, but a revised Mechanical Schedule for these units was not submitted. Provide revised Mechanical Schedule showing these units. 3. E6.01: a. The following circuits now have undersized loads in the panel schedules: 1) C1-14, 18, 20, 23, 29, 37 2) C2-13, 15, 19, 24 b. Circuit C1-34 has 2 duplex receptacles plus a refrigerator on this circuit, but is only showing a total load of 600VA in the panel schedule. Please update panel schedule load. c. Revised calculated load for C2 shows 54.75KVA yielding 228A. Panel is sized as a 225A panel with a 200A feeder, and a 200A disconnect. Please review and revise. d. When loads are updated from Comment 3.a.1 above, the calculated demand load for C1 may exceed the disconnect size and the feeder size shown. Please review and revise as necessary. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| FI1 | HOLD | 04/11/2008 | 04/14/2008 |
| Note: Held By: JPATTEE 1)Sheet A4.41, sales 103 Indicates a 24" wide walkway, this thall be a minmum of 36". OK JDP 2) sheet E6.02, fire alarm riser diagram indicates wiring devices in bedrooms of first floor units, correct me if I am wrong but this is a clubhouse, right? OK JDP 3) Sheet A1.42 symbol legend indicates sprinkler heads. Is this building sprinklered or not? OK JDP 4) Sheet A4.41 indicates doors labeled 23, 25, 26 exceed allowable swing into the corridor. OK JDP 5) Sheet ME1.43 fire alarm riser detail indicates tamper and flow switch for unsprinklered building, revise.OK JDP | |||
| MECH | COMPLETE | 04/11/2008 | 04/11/2008 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 04/11/2008 | 04/11/2008 |
| Note: Released By: FREODICA | |||
| ELEC | HOLD | 04/10/2008 | 04/10/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008040181 (Leasing Center for Integra Woods @ 1000 Integra Woods Blvd.) 4/10/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. ME1.42: a. The following lighting fixtures require circuiting: Janitor room, Men's restroom, Women's restroom. b. Ceiling fan circuit C1-26 in exercise room shows no load in panel and no load in Fixture Schedule. Furnish loads. c. Lease Office Power Riser Diagram: 1) Feeder size codes are not identified on plan sheet for size conduit and wiring. Identify feeder size codes #F23 and #F46. 2) Grounding electrode conductor size has not been provided. Provide grounding electrode conductor size per NEC. 2. ME1.43 Equipment Schedule & P6.01, P6.03: a. P6.03 shows Electric Water Heater for clubhouse to be EWH3. P6.01 shows this equipment has (2) 4500W elements. ME1.43 shows a load of only 4500W in lieu of 9000W. Please review and revise load, wire size, circuit breaker size and disconnect size. 3. ME1.43 & E6.01 - Circuit C2-38 has 7 convenience receptacles on it and an undersized load in panel. Please review and revise. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 04/09/2008 | 04/11/2008 |
| Note: Released By: FREODICA |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/27/2009 |
| REINSPECTION FEE | ¤40.00 | 02/27/2009 |
| REINSPECTION FEE | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 01/15/2009 |
| REVISION | ¤40.00 | 01/15/2009 |
| REVISION | ¤40.00 | 01/15/2009 |
| REVISION | (¤40.00) | 01/15/2009 |
| REVISION | (¤40.00) | 01/15/2009 |
| REVISION | (¤40.00) | 01/15/2009 |
| REVISION | (¤40.00) | 01/15/2009 |
| REVISION | ¤40.00 | 01/15/2009 |
| REVISION | ¤40.00 | 01/15/2009 |
| REVISION | (¤40.00) | 01/15/2009 |
| REINSPECTION FEE | (¤40.00) | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | (¤40.00) | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | (¤40.00) | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | (¤40.00) | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| BUILDING CODE ADMIN FUND | ¤41.91 | 08/15/2008 |
| ELECTRIC FEE | ¤417.60 | 08/15/2008 |
| FIRE COMM IMPACT FEE 4/1/07 | ¤430.00 | 08/15/2008 |
| FIRE PLANS REVIEW | ¤83.82 | 08/15/2008 |
| MECHANICAL FEE | ¤417.60 | 08/15/2008 |
| PERMIT FEE | ¤3,573.00 | 08/15/2008 |
| PLAN CHECK FEE | ¤742.90 | 08/15/2008 |
| PLUMBING FEE | ¤417.60 | 08/15/2008 |
| RADON FEE | ¤41.91 | 08/15/2008 |
| REVISION | ¤240.00 | 08/15/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤7,046.34 |