Permit #2008040189
Permit Details
Status: COED
| Parcel Id: 31-12-31-5371-00000-0040 |
| CONDITIONED SPACE: 29352 sqft |
| GARAGE: 2892 sqft |
| OPENED PORCH (WITH ROOF) : 2704 sqft |
| Total Square Footage: 34948 sqft |
| Block: 00000 |
| Subdivision: 2138 - SEMINOLE POINTE SUBDIVISION |
| Job Phone: 386-586-2806 |
| Location Address: 200 SHADY OAKS DR |
| Type: BM - BUILDING MULTI - APARTMENT |
| Issue Date: 07/10/2008 |
| NOC: RECORDED |
| Applicant name: JAMES G PYLE |
| Owner: PALM COAST SEMINOLE GROUP LLC 1 FLORIDA PARK DRIVE |
|
Address #307 PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤1,680,487.00 |
| Job Description: BUILDING 1- TYPE 2 (3 FLOORS, 32 APT. UNITS) SP-MAJ-07-06 FOR "INTEGRA WOODS" |
| Type: CN |
Contractor
LANDSOUTH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1680 THE GREENS WAY JACKSONVILLE , FL 32277 |
CBC035104 (Exp: 08/31/2010) | 386-586-0781 | 386-586-2805 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
NINO JOE PARRALES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6824 PHILLIPS PKWY DR. S JACKSONVILLE , FL 32256 |
CAC057164 (Exp: 08/31/2010) | (904)346-1774 | (904)346-4788 |
STEPHEN JOHN CHASTAIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1923 TAMPA EAST BLVD TAMPA, FL 33619 |
CFC024520 (Exp: 08/31/2012) | (813)246-5341 | (813)246-5345 |
FRED M POMAR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1025 6TH STREET DAYTONA BEACH, FL 32117 |
CCC1328140 (Exp: 08/31/2010) | (386)255-6113 | (386)254-8816 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/27/2009 | FINAL APPROVED | LWOODROME |
| Note: Approval based on previous inspection | |||
| LANDSCAPE FINAL | 02/26/2009 | APPROVED - AS NOTED | WBUTLER |
| Note: A performance bond was received in the amount of $186,585.70 to cover the unfinished landscape and irrigation work. | |||
| COMMERCIAL BUILDING FINAL | 02/26/2009 | APPROVED - AS NOTED | JHINDMAN |
| Note: Inspection Resulted at 2/26/2009 3:28:24 PM BUILDING FINAL OK BUT CANNOT CO UNTIL OTHER DEPARTMENTS INSPECTIONS HAVE BEEN APPROVED | |||
| UTILITY COMMERCIAL FINAL | 02/25/2009 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 02/25/2009 | APPROVED | KKING |
| ENGINEERING FINAL | 02/25/2009 | APPROVED | MCOBB |
| Note: per Don. S. | |||
| TRAFFIC ENGINEER | 02/25/2009 | APPROVED | MCOBB |
| Note: per Don S. | |||
| ELECTRICAL FINAL | 02/25/2009 | APPROVED | JHINDMAN |
| FIRE FINAL | 02/24/2009 | APPROVED | JPATTEE |
| H.V.A.C. FINAL | 02/20/2009 | APPROVED | JHINDMAN |
| Note: Inspection Requested at 2/19/2009 4:56:21 PM AFTERNOON REQUESTED | |||
| PLUMBING FINAL | 02/18/2009 | APPROVED | JHINDMAN |
| UNDERGROUND ELECTRICAL | 01/23/2009 | APPROVED | RMARVEL |
| Note: Inspection Requested at 1/22/2009 4:22:51 PM CONDUIT / STREET LIGHTING | |||
| COMMERCIAL POWER INSPECTION | 01/23/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Requested at 1/22/2009 4:08:02 PM CONDUIT INSPECTION Inspection Resulted at 1/23/2009 2:02:47 PM NOT READY. | |||
| COMMERCIAL POWER INSPECTION | 01/23/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL POWER INSPECTION | 01/22/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 1/22/2009 3:35:40 PM NOT READY | |||
| INSULATION INSPECTION | 12/08/2008 | APPROVED | JHINDMAN |
| FRAMING | 12/05/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/05/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 12/04/2008 | APPROVED | JHINDMAN |
| FRAMING | 12/04/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Requested at 12/3/2008 5:14:13 PM AFTER LUNCH INSPECTION IF POSSIBLE Inspection Resulted at 12/4/2008 2:01:22 PM 1. BLOCKING MISSING. 2. TRUSS REPAIRS NEEDED CENTER WALLS 3. NEED TO FIX OVER BORING OF STUDS MANY PLACES. | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/04/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 12/3/2008 5:14:45 PM AFTER LUNCH INSPECTION IF POSSIBLE Inspection Resulted at 12/4/2008 2:01:21 PM PIPING SUPPORTS MISSING SEVERAL PLACES. STRAPPING MISSING, NEED TO CHECK DWV TEST. | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/02/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/2/2008 3:21:35 PM 1. ISOMETRIC DETAILS S8 AND S9A DO NOT MATCH AS BUILT. 2. RECHECK NAIL PLATES AND OVER BORING REPAIRS. 3. STRAP VENT STACKS IN ATTIC. | |||
| H.V.A.C. ROUGH | 11/25/2008 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| SECOND ROUGH PLUMBING INSPECTION | 11/17/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION squedule by Robyn Inspection Resulted at 11/17/2008 3:49:47 PM NOT PER PLAN | |||
| SECOND ROUGH PLUMBING INSPECTION | 11/14/2008 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: Inspection Resulted at 11/14/2008 10:35:48 AM BY DAVE | |||
| H.V.A.C. ROUGH | 11/14/2008 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: Inspection Resulted at 11/14/2008 10:52:27 AM LAUNDRY ROOM DUCT WORK PINCHED. "E" UNITS.TRANSFER DUCT AT FRONT AND REAR BED ROOMS MISSING IN UNITS. location of exhaust in bathrooms not to plan | |||
| 2ND ROUGH ELECTRICAL | 11/14/2008 | APPROVED - AS NOTED | LHITES |
| Note: THIS IS A REINSPECTION Inspection Resulted at 11/14/2008 11:28:22 AM MOVE A/C WIRES FROM EDGE OF 2X4 REPLACE JUMPER IN UNIT 310 | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/13/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| TIE DOWN | 11/12/2008 | APPROVED | BBEMBRY |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/10/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 11/7/2008 4:25:39 PM WINDOW SCREW INSPECTION Inspection Resulted at 11/10/2008 3:44:47 PM WINDOW SCREWS | |||
| 2ND ROUGH ELECTRICAL | 11/10/2008 | CANCELLED BY APPLICANT | RMARVEL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/07/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 11/7/2008 3:10:19 PM TRUSS BRACING COMPLETE | |||
| FIREWALL INSPECTION | 11/05/2008 | APPROVED | JPATTEE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/30/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 10/30/2008 3:25:16 PM 1. FIRST FLOOR AND NORTH HALF OF 2ND FLOOR, FLOOR TRUSSES DO NOT BEAR COMPLETELY PER ENGINEERING.2. 3RD FLOOR NORTH SIDE END UNITS, HJHC26 VST ANCHOR IS NOT PER TRUSS ENGINEERING. 4. UNIT 300, TRUSS R125 MISSING TOP PLATE. 5. UNIT 300 VALLEY STRAPS NOT ANCHORED. 6. SMOOKE WALLS ARE NOT COMPLETE. 7. LS18``S MISSING ON CENTER BEARING WALLS. 8. UNIT 302, R124 AND R125 GIRDER TRUSSES ARE NOT NAILED PER ENGINEERING. 9. REAR BREEZEWAY OUTSIDE OF UNIT 302 R65A MISSING NAILS IN BUCKET. DID NOT WALK 2ND AND 3RD FLOOR SOUTH SIDE UNITS. | |||
| FIREWALL INSPECTION | 10/23/2008 | APPROVED - AS NOTED | JLEWIS |
| Note: 1st layer drywall. needs second layer | |||
| ROOF IN PROGRESS | 10/16/2008 | APPROVED | JHINDMAN |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/16/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/15/2008 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 10/15/2008 2:31:01 PM CANCELLED BY JOHN | |||
| FOUNDATION SURVEY APPROVED BY ZONING | 10/10/2008 | APPROVED | DRAMIREZ |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/09/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: called by contractor Inspection Resulted at 10/9/2008 2:00:09 PM ROOF SHEATHING IS OK | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/09/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: called by contractor Inspection Resulted at 10/9/2008 2:00:09 PM PORCH COLUMN FRAMING IS OK, BREEZEWAY SHEATHING IS OK. | |||
| TEMPORARY POLE | 08/19/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/19/2008 1:57:27 PM TRI CITY | |||
| TEMPORARY POLE | 08/15/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 8/15/2008 3:35:16 PM LOOSE CONNECTIONS | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 07/24/2008 | APPROVED - AS NOTED | CMINI |
| Note: POST TENSION SLAB ON BUILDING 1...... | |||
| FIRST ROUGH PLUMBING INSPECTION | 07/18/2008 | APPROVED | PGALLMANN |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 03/25/2009 | 03/25/2009 |
| Note: Released By: FREODICA Revision: Air handler tonage changed (Rev. 12, dated 2-23-09.) | |||
| ELEC | COMPLETE | 03/25/2009 | 03/27/2009 |
| Note: Released By: SKNOPF Approved for Release. Revised house panel schedules/site lighting circuit schedule. | |||
| ELEC | COMPLETE | 02/24/2009 | 02/25/2009 |
| Note: Released By: JMCGOWEN Revision site lighting | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN Revision adding of hallway light | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN Revision deletion of GFI receptacle in bathroom move hall switch | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN revision addition of closet light (garage) | |||
| ELEC | HOLD | 01/30/2009 | 01/30/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Integra Woods #2008040172, 2008040174, 2008040177, 2008040181, 2008040182, 2008040183, 2008040184, 2008040185, 2008040186, 2008040187, 2008040188, 2008040189, 2008040190, 2008040191, 2008040192, 2008040193, 2008040194, 2008040195, 2008040198, 2008040200, 2008040202, 2008040203, 2008040204, 2008040205 1/30/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. This plan sheet shows circuits P-1, 2, 3, 4 and 6 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. b. This plan sheet shows circuit TC-2 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. c. A total of 4000W of fixture load is shown on a 1P20A circuit breaker on circuit HP3-10. Panel schedule shows an 1100W total load for both HP3-10 and HP3-11. Revise. d. A total of 3900W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-20. Panel schedule shows a 2800W total load for 3 circuits, HP1-20, 22, and 24. Revise. e. A total of 2700W of fixture load is shown on a 1P20A circuit breaker on circuit HP2-17. Revise. f. A total of 4100W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-22. Revise. g. Circuit HP2-17 thru 19 is shown as Bldg/Site lights in panel schedule, but HP2-19 does not appear on E1.01 Site Plan. Coordinate. 2. E1.91: a. Compactor Power Riser Diagram shows #6 grounding electrode conductor for a #250 Aluminum service feeder. Revise grounding electrode conductor on this sheet per NEC Table 250.66 and Grounding Electrode Table on Sheet E6.02. b. Identify HP for garage door opener circuit S-3 and GP-1, 2. Panel shows load is only 500W per motor, which would make motor smaller than 1/4HP. Confirm HP size for motor and provide load in panel schedule per NEC Table 430.248. c. Mail Kiosk Detail 1 does not identify circuit number or which Clubhouse Panel the Mail Kiosk lighting is fed from. E6.01 Clubhouse panel schedules also do not reflect Mail Kiosk lighting. Revise. d. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L1E is 2P60A on circuit C1-2:4. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. e. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L2I is 2P60A on circuit C1-6:8. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. f. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L3 is 2P60A with a 5.7KVA load on circuit C1-10:12. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. g. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L5 is 2P60A with a 5.7KVA load on circuit C2-6:8. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. h. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L4 is 2P60A on circuit C2-35:37. Panel Schedule on E6.01 has a 2P50A circuit breaker for this unit. Resolve conflict. i. Equipment Schedule ME1.43 still shows HVAC unit PTHP1 on a 2P60A circuit breaker on C2-2:4. Panel schedule C2 now shows this circuit as blank. If PTHP1 is no longer an HVAC unit on this building, delete unit from equipment schedule and submit revised drawings. Resolve conflict. j. Revise loads for circuit GP-3, 4 which are undersized in panel schedule. 3. E6.01 and E1.01: Clarify how (1) 2P40A circuit breaker on circuit HP1-16:18 is protecting feeders to (2) MLO sub-panels, "GP" and "S", in accordance with NEC 240.21(B)(5). 4. E6.02: a. Clubhouse Service Calculation - revise loads for panels in load calculation to match Demand Loads calculated in Panel Schedules on Sheet E6.01. b. Indicate which House Panel is associated with each Load Calculation for Meter Centers A & B, Bldg. Types 1, 2, and 3. Also indicate building number where each Meter Center is located. c. Revise Demand Load Calculations for Meter Centers A & B, Buildings 1, 2, and 3 to reflect Demand Load, not Connected Loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | COMPLETE | 01/27/2009 | 01/28/2009 |
| Note: Released By: FREODICA Revision: Specs for washers/dryers in A1 & E units. | |||
| BLD | COMPLETE | 01/26/2009 | 01/26/2009 |
| Note: Released By: JJOSEPH Revision screen enclosure submittals and location | |||
| PLLA | CANCEL | 01/21/2009 | |
| ELEC | HOLD | 01/21/2009 | 01/21/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008040189 (Integra Woods Bldg 1 Type 2 @ 200 Shady Oaks Dr.) 1/21/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. Information on Sheet E1.01 regarding Electrical service feeders from FPL transformers has been deleted from this plan sheet. Reinsert this information back on this sheet. b. Identify panel circuits on plan sheet and provide revised House panel schedules with updated load calculations. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | COMPLETE | 01/06/2009 | 01/06/2009 |
| Note: Released By: FREODICA Revision: E- unit type alternate bathroom exhaust route. | |||
| PLUM | COMPLETE | 12/19/2008 | 12/22/2008 |
| Note: Released By: FREODICA Revision: Sealed letter concerning washer location. | |||
| PLUM | COMPLETE | 11/26/2008 | 12/01/2008 |
| Note: Released By: FREODICA revision submitted 11/26/08 - "Plumbing Revisions for Entire Building System" Revised sheets P1.21, P1.21a, P1.22, P1.23, P6.01, P6.02 & P6.04. | |||
| MECH | COMPLETE | 11/19/2008 | 11/19/2008 |
| Note: Released By: FREODICA Revision Removed (2) radiation ceiling dampers at bedroom #2 Unit E on Sheet M4.06 and installed wall return above door. | |||
| ZON | CANCEL | 11/19/2008 | |
| MECH | COMPLETE | 11/18/2008 | 11/19/2008 |
| Note: Released By: JJOSEPH Revision alternate exhaust location | |||
| BLD | COMPLETE | 11/06/2008 | 11/06/2008 |
| Note: Released By: JMCGOWEN truss repair revision | |||
| PLUM | HOLD | 10/22/2008 | 10/24/2008 |
| Note: Held By: FREODICA Revision: Plans shall be signed and sealed by FL. Reg. Engr. | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION Roofing submittals | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION code compliant Hardware | |||
| BLD | COMPLETE | 10/22/2008 | 10/24/2008 |
| Note: Released By: JJOSEPH Revision Third floor: Removal of columns, cap and flashing details cabinet change/shelving change | |||
| DSD | HOLD | 10/02/2008 | 10/06/2008 |
| Note: Held By: DRAMIREZ Architectural plans need to be modified. On hold until modification is approved. | |||
| BLD | COMPLETE | 09/15/2008 | 09/22/2008 |
| Note: Released By: JJOSEPH Anchor placement plans that show anchor spacing for all bearing walls REVISION | |||
| BLD | COMPLETE | 07/02/2008 | 07/03/2008 |
| Note: Released By: FREODICA Rev. - Architectural , structural, and mech. sheets. | |||
| ELEC | COMPLETE | 07/02/2008 | 07/02/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision - Relocated switches and CU risers in garage. Relocated FACP, FACP heat detector, and FACP signage. Deleted AHU-FACP & CU-FACP and replaced with PTAC-F at ne FACP closet under stairwell. Relocated Owner Closet receptacles to Garage area. | |||
| BLD | COMPLETE | 05/09/2008 | 05/09/2008 |
| Note: Released By: FREODICA Correction Energy calculations | |||
| FI1 | COMPLETE | 05/09/2008 | 05/12/2008 |
| Note: Released By: JPATTEE correction Fire sprinkler design criteria | |||
| ELEC | COMPLETE | 04/10/2008 | 04/10/2008 |
| Note: Released By: FREODICA Reviewed by R. Marvel. | |||
| FI1 | HOLD | 04/10/2008 | 04/23/2008 |
| Note: Held By: JPATTEE 1) Plans do not provide design criteria for automatic fire sprinkler system(s) 2) Unable to locate detail for the rated garage wall and rated floor ceiling. | |||
| MECH | COMPLETE | 04/10/2008 | 04/10/2008 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 04/10/2008 | 04/10/2008 |
| Note: Released By: FREODICA | |||
| BLD | HOLD | 04/09/2008 | 04/10/2008 |
| Note: Held By: FREODICA 1. Provide energy calculations for building 1, type ll, Unit E, second floor. This is typical for building 6 ( permit application # 2008040190) and building 20 (permit application # 2008040191). | |||
| DSD | COMPLETE | 10/24/2008 | |
| Note: Released By: DRAMIREZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤120.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| REVISION | ¤40.00 | 02/27/2009 |
| SPECIAL INSPECTIONS | ¤200.00 | 02/27/2009 |
| REINSPECTION FEE | ¤40.00 | 02/09/2009 |
| REINSPECTION FEE | ¤40.00 | 02/09/2009 |
| REINSPECTION FEE | ¤40.00 | 02/09/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/05/2009 |
| REINSPECTION FEE | ¤40.00 | 12/23/2008 |
| REINSPECTION FEE | ¤40.00 | 08/18/2008 |
| ADMIN FEE | ¤20.00 | 07/10/2008 |
| BUILDING CODE ADMIN FUND | ¤174.74 | 07/10/2008 |
| ELECTRIC FEE | ¤1,810.80 | 07/10/2008 |
| FIRE IMPACT FEE RES 4/01/08 | ¤6,089.28 | 07/10/2008 |
| MECHANICAL FEE | ¤1,810.80 | 07/10/2008 |
| PERMIT FEE | ¤16,324.00 | 07/10/2008 |
| PARKS IMPACT FEE 4/01/08 | ¤39,347.20 | 07/10/2008 |
| PLUMBING FEE | ¤1,810.80 | 07/10/2008 |
| RADON FEE | ¤174.74 | 07/10/2008 |
| SCHOOL BOARD IMPACT FEE MULTI | ¤29,792.00 | 07/10/2008 |
| REVISION | ¤20.00 | 07/10/2008 |
| REVISION | ¤40.00 | 07/10/2008 |
| 10/07 TRANS MULTI - FAMILY | ¤71,243.20 | 07/10/2008 |
| REVISION | ¤40.00 | |
| REVISION | ¤40.00 | |
| Fees | Total Due: ¤80.00 | Total Paid: ¤169,897.56 |