Permit #2008040190
Permit Details
Status: COED
| Parcel Id: 31-12-31-5371-00000-0040 |
| CONDITIONED SPACE: 29352 sqft |
| GARAGE: 2892 sqft |
| OPENED PORCH (WITH ROOF) : 2704 sqft |
| Total Square Footage: 34948 sqft |
| Block: 00000 |
| Subdivision: 2138 - SEMINOLE POINTE SUBDIVISION |
| Job Phone: 386-586-2806 |
| Location Address: 400 SHADY OAKS DR |
| Type: BM - BUILDING MULTI - APARTMENT |
| Issue Date: 07/10/2008 |
| NOC: RECORDED |
| Applicant name: JAMES G PYLE |
| Owner: PALM COAST SEMINOLE GROUP LLC 1 FLORIDA PARK DRIVE |
|
Address #307 PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤1,680,487.00 |
| Job Description: BUILDING 6- TYPE 2 (3 FLOORS, 32 APT. UNITS) SP-MAJ-07-06 FOR "INTEGRA WOODS" |
| Type: CN |
Contractor
LANDSOUTH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1680 THE GREENS WAY JACKSONVILLE , FL 32277 |
CBC035104 (Exp: 08/31/2010) | 386-586-0781 | 386-586-2805 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
NINO JOE PARRALES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6824 PHILLIPS PKWY DR. S JACKSONVILLE , FL 32256 |
CAC057164 (Exp: 08/31/2010) | (904)346-1774 | (904)346-4788 |
STEPHEN JOHN CHASTAIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1923 TAMPA EAST BLVD TAMPA, FL 33619 |
CFC024520 (Exp: 08/31/2012) | (813)246-5341 | (813)246-5345 |
FRED M POMAR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1025 6TH STREET DAYTONA BEACH, FL 32117 |
CCC1328140 (Exp: 08/31/2010) | (386)255-6113 | (386)254-8816 |
Inspection History
| Type | Request Date | Result | Inspector |
| ENGINEERING FINAL | 04/21/2009 | APPROVED | MCOBB |
| TRAFFIC ENGINEER | 04/21/2009 | APPROVED | MCOBB |
| UTILITY COMPANY FINAL | 04/21/2009 | APPROVED | KKING |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL BUILDING FINAL | 04/20/2009 | FINAL APPROVED | JHINDMAN |
| Note: Inspection Resulted at 4/20/2009 3:45:20 PM FINAL BUILDING IS OK BUT CANNOT 99 UNTIL OTHER DEPARTMENTS HAVE SIGNED OFF. | |||
| COMMERCIAL BUILDING FINAL | 04/17/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 4/17/2009 12:56:46 PM FIRE SEAL HVAC CLOSETS | |||
| LANDSCAPE FINAL | 04/15/2009 | APPROVED | WBUTLER |
| UTILITY COMMERCIAL FINAL | 04/13/2009 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 04/13/2009 | Disapproved - NO FEE | KKING |
| Note: Meters need to be checked and accounts set up. After that recall inspection. | |||
| H.V.A.C. FINAL | 04/09/2009 | APPROVED | JHINDMAN |
| ELECTRICAL FINAL | 04/03/2009 | APPROVED - AS NOTED | RMARVEL |
| Note: Inspection Resulted at 4/3/2009 3:23:42 PM CHECK PANEL SCHEDULE PER PLOANS. E UNIT A/C UNITS WERE NOT CORRECT. | |||
| FIRE FINAL | 04/02/2009 | APPROVED | JPATTEE |
| PLUMBING FINAL | 03/31/2009 | APPROVED | JHINDMAN |
| UNDERGROUND ELECTRICAL | 03/24/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 3/23/2009 4:01:32 PM SITE LIGHTING | |||
| UNDERGROUND ELECTRICAL | 03/23/2009 | CANCELLED BY APPLICANT | RMARVEL |
| Note: Inspection Requested at 3/20/2009 1:50:46 PM SITE LIGHTING | |||
| COMMERCIAL POWER INSPECTION | 03/06/2009 | APPROVED | RMARVEL |
| LATH /BRICK FLASHING | 01/09/2009 | APPROVED | JHINDMAN |
| Note: Inspection Requested at 1/8/2009 3:24:42 PM LATHE | |||
| H.V.A.C. ROUGH | 01/07/2009 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION Inspection Requested at 1/6/2009 3:36:32 PM HVAC REINSPECT | |||
| INSULATION INSPECTION | 01/07/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 12/31/2008 | CANCELLED BY APPLICANT | DROCKWELL |
| H.V.A.C. ROUGH | 12/23/2008 | Disapproved -FEE REQUIRED | LWOODROME |
| Note: Inspection Resulted at 12/23/2008 2:59:41 PM NEED REVISION FOR EF -1 DUCT LOCATIN FOR E UNITS. 2.. STRAP EF DUCTS AS REQUIRED IN ALL UNITS. 3. UNIT 207 DUCT PINCHED AT A/C CLOSET.4 UNITS 204 AND 205 BELLY IN EF DUCT. ....OK TO INSULATE...VERIFY CORRCTIONS AT INSULATION INSPECTION. | |||
| FRAMING | 12/23/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/23/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/19/2008 | CANCELLED BY APPLICANT | AIRS WEB |
| Note: Inspection Requested at 12/18/2008 6:15:39 AM THIS INSPECTION IS FOR 12/18. | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/19/2008 | CANCELLED BY APPLICANT | AIRS WEB |
| Note: Inspection Requested at 12/18/2008 6:15:39 AM THIS INSPECTION IS FOR 12/18. Inspection Requested at 12/18/2008 6:16:55 AM THIS INSPECTION IS FOR 12/18. COMPUTER PROBLEM | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/19/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Requested at 12/18/2008 6:15:39 AM THIS INSPECTION IS FOR 12/18. Inspection Requested at 12/18/2008 6:16:55 AM THIS INSPECTION IS FOR 12/18. COMPUTER PROBLEM Inspection Resulted at 12/19/2008 3:01:27 PM BRANCH ARMS FOR THE KITCHEN SINKS ARE NOT PER PLAN. STRAP AND SUPPORT DWV SYSTEM AT LAST ELBOWS. | |||
| 2ND ROUGH ELECTRICAL | 12/17/2008 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| 2ND ROUGH ELECTRICAL | 12/12/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 12/12/2008 3:56:56 PM OUTER INSULATION NEEDS TO ENTER BOX .25IN. RECHECK NAIL PLATES. REMOVE STRAPS FROM GUSSETT PLATES. LAND CONDUCTORS COMPLETELY UNDEDR LUGS. TORQUE ALL LUGS TO PROPER SPECIFICATIONS. ADD RECEPTACLE ON WALLS 24IN OR GREATER. | |||
| FRAMING | 11/20/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Requested at 11/19/2008 4:26:41 PM WINDOW SCREW INSPECTION Inspection Resulted at 11/20/2008 3:20:51 PM WINDOW ANCHORS | |||
| FIREWALL INSPECTION | 11/19/2008 | APPROVED | JPATTEE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/17/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/12/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 11/10/2008 5:11:50 PM TRUSSES Inspection Resulted at 11/12/2008 3:59:50 PM 1. UNIT 305 MISSING BRACE R68. 2. R63 AND R64 IN UNITS 303 AND 301 | |||
| TIE DOWN | 11/12/2008 | APPROVED | BBEMBRY |
| Note: letter submitted from engineer regarding the quick tie cables | |||
| ROOF IN PROGRESS | 11/12/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL INSPECTION | 11/12/2008 | Disapproved - NO FEE | JPATTEE |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 11/06/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 11/5/2008 11:12:54 PM REINSPECT EXTERIOR WALL SHEATHING | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 11/05/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 11/5/2008 3:37:17 PM NAILS TO DEEP IN MANY AREAS | |||
| ROOF IN PROGRESS | 11/05/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 11/5/2008 3:37:18 PM ROOF METALS ARE NOT COMPLETE. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/28/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 10/28/2008 2:01:45 PM ROOF SHEATHING IS OK | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/28/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 10/28/2008 2:01:45 PM PORCHES AND BREEZEWAYS | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/27/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 10/27/2008 3:03:26 PM SOUTH BREEZEWAY IS NOT COMPLETE FOR BREEZEWAY AND PORCH INSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/27/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 10/27/2008 3:03:25 PM NOT READY | |||
| FOUNDATION SURVEY APPROVED BY ZONING | 10/10/2008 | APPROVED | DRAMIREZ |
| TEMPORARY POLE | 10/06/2008 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 10/6/2008 2:35:44 PM TRICITY | |||
| TEMPORARY POLE | 08/19/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| TEMPORARY POLE | 08/15/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 8/15/2008 3:35:16 PM STRAP LFNC. TIGHTEN CONNECTORS. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 08/15/2008 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 08/12/2008 | APPROVED | PGALLMANN |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 03/25/2009 | 03/25/2009 |
| Note: Released By: FREODICA Revision: Air handler tonage changed (Rev. 12, dated 2-23-09.) | |||
| ELEC | COMPLETE | 03/25/2009 | 03/27/2009 |
| Note: Released By: SKNOPF Approved for Release. Revised house panel schedules/site lighting circuit schedule | |||
| ELEC | COMPLETE | 02/24/2009 | 02/25/2009 |
| Note: Released By: JMCGOWEN revision site lighting | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN Revision Adding of hallway light | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN Revision deletion of GFI receptacle in bathroom move hall switch | |||
| ELEC | COMPLETE | 02/23/2009 | 02/24/2009 |
| Note: Released By: JMCGOWEN revision addition of closet lighting (garage) | |||
| ELEC | HOLD | 01/30/2009 | 01/30/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Integra Woods #2008040172, 2008040174, 2008040177, 2008040181, 2008040182, 2008040183, 2008040184, 2008040185, 2008040186, 2008040187, 2008040188, 2008040189, 2008040190, 2008040191, 2008040192, 2008040193, 2008040194, 2008040195, 2008040198, 2008040200, 2008040202, 2008040203, 2008040204, 2008040205 1/30/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. This plan sheet shows circuits P-1, 2, 3, 4 and 6 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. b. This plan sheet shows circuit TC-2 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. c. A total of 4000W of fixture load is shown on a 1P20A circuit breaker on circuit HP3-10. Panel schedule shows an 1100W total load for both HP3-10 and HP3-11. Revise. d. A total of 3900W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-20. Panel schedule shows a 2800W total load for 3 circuits, HP1-20, 22, and 24. Revise. e. A total of 2700W of fixture load is shown on a 1P20A circuit breaker on circuit HP2-17. Revise. f. A total of 4100W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-22. Revise. g. Circuit HP2-17 thru 19 is shown as Bldg/Site lights in panel schedule, but HP2-19 does not appear on E1.01 Site Plan. Coordinate. 2. E1.91: a. Compactor Power Riser Diagram shows #6 grounding electrode conductor for a #250 Aluminum service feeder. Revise grounding electrode conductor on this sheet per NEC Table 250.66 and Grounding Electrode Table on Sheet E6.02. b. Identify HP for garage door opener circuit S-3 and GP-1, 2. Panel shows load is only 500W per motor, which would make motor smaller than 1/4HP. Confirm HP size for motor and provide load in panel schedule per NEC Table 430.248. c. Mail Kiosk Detail 1 does not identify circuit number or which Clubhouse Panel the Mail Kiosk lighting is fed from. E6.01 Clubhouse panel schedules also do not reflect Mail Kiosk lighting. Revise. d. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L1E is 2P60A on circuit C1-2:4. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. e. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L2I is 2P60A on circuit C1-6:8. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. f. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L3 is 2P60A with a 5.7KVA load on circuit C1-10:12. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. g. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L5 is 2P60A with a 5.7KVA load on circuit C2-6:8. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. h. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L4 is 2P60A on circuit C2-35:37. Panel Schedule on E6.01 has a 2P50A circuit breaker for this unit. Resolve conflict. i. Equipment Schedule ME1.43 still shows HVAC unit PTHP1 on a 2P60A circuit breaker on C2-2:4. Panel schedule C2 now shows this circuit as blank. If PTHP1 is no longer an HVAC unit on this building, delete unit from equipment schedule and submit revised drawings. Resolve conflict. j. Revise loads for circuit GP-3, 4 which are undersized in panel schedule. 3. E6.01 and E1.01: Clarify how (1) 2P40A circuit breaker on circuit HP1-16:18 is protecting feeders to (2) MLO sub-panels, "GP" and "S", in accordance with NEC 240.21(B)(5). 4. E6.02: a. Clubhouse Service Calculation - revise loads for panels in load calculation to match Demand Loads calculated in Panel Schedules on Sheet E6.01. b. Indicate which House Panel is associated with each Load Calculation for Meter Centers A & B, Bldg. Types 1, 2, and 3. Also indicate building number where each Meter Center is located. c. Revise Demand Load Calculations for Meter Centers A & B, Buildings 1, 2, and 3 to reflect Demand Load, not Connected Loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | COMPLETE | 01/27/2009 | 01/28/2009 |
| Note: Released By: FREODICA Revision: Specs for washers/dryers in A1& E units. | |||
| BLD | COMPLETE | 01/26/2009 | 01/26/2009 |
| Note: Released By: JJOSEPH Revision Screen enclosure submittals and location | |||
| ELEC | HOLD | 01/21/2009 | 01/21/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008040190 (Integra Woods Bldg 6 Type 2 @ 400 Shady Oaks Dr.) 1/21/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. Information on Sheet E1.01 regarding Electrical service feeders from FPL transformers has been deleted from this plan sheet. Reinsert this information back on this sheet. b. Identify panel circuits on plan sheet and provide revised House panel schedules with updated load calculations. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| PLLA | COMPLETE | 01/21/2009 | 01/22/2009 |
| Note: Released By: WBUTLER | |||
| MECH | COMPLETE | 01/06/2009 | 01/06/2009 |
| Note: Released By: FREODICA Revision: E- UNIT TYPE ALTERNATE BATHROOM EXHAUST ROUTE. | |||
| PLUM | COMPLETE | 12/19/2008 | 12/22/2008 |
| Note: Released By: FREODICA Revision: Sealed letter concerning washer location. | |||
| BLD | COMPLETE | 12/18/2008 | 12/18/2008 |
| Note: Released By: JJOSEPH Revision: Applying Simpson RPS28 Straps. | |||
| PLUM | COMPLETE | 11/26/2008 | 12/01/2008 |
| Note: Released By: FREODICA Revision submitted 11/26/08 - "Plumbing Revisions for Entire Building System" Revised sheets P1.21, P1.21a, P1.22, P1.23, P6.01, P6.02 & P6.04. | |||
| MECH | COMPLETE | 11/19/2008 | 11/19/2008 |
| Note: Released By: FREODICA Revision 1. Removed (2) radiation ceiling dampers and installed wall return at bedroom #2 Unit E shown on sheet M4.06. | |||
| ZON | CANCEL | 11/19/2008 | |
| MECH | COMPLETE | 11/18/2008 | 11/19/2008 |
| Note: Released By: JJOSEPH Revision Alternate exhaust location | |||
| BLD | COMPLETE | 11/06/2008 | 11/06/2008 |
| Note: Released By: JMCGOWEN revision for trusses | |||
| PLUM | HOLD | 10/22/2008 | 10/24/2008 |
| Note: Held By: FREODICA Revision: Plans shall be signed and sealed by FL. Reg. Engr. | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION Roofing submittals | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION code compliant Hardware | |||
| PLUM | COMPLETE | 10/22/2008 | 10/24/2008 |
| Note: Released By: JJOSEPH Revision Third floor: Removal of columns, cap and flashing details cabinet change/shelving change | |||
| DSD | HOLD | 10/02/2008 | 10/06/2008 |
| Note: Held By: DRAMIREZ Architectural plans need to be modified. On hold until modification is approved. | |||
| BLD | COMPLETE | 09/15/2008 | 09/22/2008 |
| Note: Released By: JJOSEPH Anchor placement plans that show anchor spacing for all bearing walls REVISION | |||
| BLD | COMPLETE | 07/02/2008 | 07/03/2008 |
| Note: Released By: FREODICA Rev.- Arch., struct., and mech. sheets. | |||
| ELEC | COMPLETE | 07/02/2008 | 07/02/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision - Relocated switches and CU risers in garage. Relocated FACP, FACP heat detector, and FACP signage. Deleted AHU-FACP & CU-FACP and replaced with PTAC-F at ne FACP closet under stairwell. Relocated Owner Closet receptacles to Garage area. | |||
| BLD | COMPLETE | 05/09/2008 | 05/09/2008 |
| Note: Released By: FREODICA | |||
| FI1 | COMPLETE | 05/09/2008 | 05/12/2008 |
| Note: Released By: JPATTEE | |||
| ELEC | COMPLETE | 04/10/2008 | 04/10/2008 |
| Note: Released By: FREODICA Reviewed by R. Marvel. | |||
| FI1 | HOLD | 04/10/2008 | 04/23/2008 |
| Note: Held By: JPATTEE 1) Plans do not provide design criteria for automatic fire sprinkler system(s) 2) Unable to locate detail for the rated garage wall and rated floor ceiling. | |||
| MECH | COMPLETE | 04/10/2008 | 04/10/2008 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 04/10/2008 | 04/10/2008 |
| Note: Released By: FREODICA | |||
| BLD | HOLD | 04/09/2008 | 04/10/2008 |
| Note: Held By: FREODICA 1. Provide energy calculations for building type ll, unit E, second floor. | |||
| DSD | COMPLETE | 10/24/2008 | |
| Note: Released By: DRAMIREZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/21/2009 |
| REINSPECTION FEE | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | 04/21/2009 | |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤80.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REINSPECTION FEE | ¤40.00 | 02/09/2009 |
| REINSPECTION FEE | ¤40.00 | 01/27/2009 |
| REINSPECTION FEE | ¤40.00 | 01/26/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 01/15/2009 |
| REINSPECTION FEE | ¤40.00 | 08/18/2008 |
| ADMIN FEE | ¤20.00 | 07/10/2008 |
| BUILDING CODE ADMIN FUND | ¤174.74 | 07/10/2008 |
| ELECTRIC FEE | ¤1,810.80 | 07/10/2008 |
| FIRE IMPACT FEE RES 4/01/08 | ¤6,089.28 | 07/10/2008 |
| MECHANICAL FEE | ¤1,810.80 | 07/10/2008 |
| PERMIT FEE | ¤16,324.00 | 07/10/2008 |
| PARKS IMPACT FEE 4/01/08 | ¤39,347.20 | 07/10/2008 |
| PLUMBING FEE | ¤1,810.80 | 07/10/2008 |
| RADON FEE | ¤174.74 | 07/10/2008 |
| REVISION | ¤20.00 | 07/10/2008 |
| REVISION | ¤40.00 | 07/10/2008 |
| SCHOOL BOARD IMPACT FEE MULTI | ¤29,792.00 | 07/10/2008 |
| 10/07 TRANS MULTI - FAMILY | ¤71,243.20 | 07/10/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤169,777.56 |