I want to search for...
Permit #2008040194
Permit Details
Status: COED
| Parcel Id: 31-12-31-5371-00000-0040 |
| CONDITIONED SPACE: 30040 sqft |
| OPENED PORCH (WITH ROOF) : 2476 sqft |
| GARAGE: 3892 sqft |
| OPENED PORCH (WITH ROOF) : 6286 sqft |
| Total Square Footage: 42694 sqft |
| Block: 00000 |
| Subdivision: 2138 - SEMINOLE POINTE SUBDIVISION |
| Job Phone: 386-586-0781 |
| Location Address: 555 SHADY OAKS DR |
| Type: BM - BUILDING MULTI - APARTMENT |
| Issue Date: 07/22/2008 |
| NOC: RECORDED |
| Applicant name: JAMES G PYLE |
| Owner: PALM COAST SEMINOLE GROUP LLC 1 FLORIDA PARK DRIVE |
|
Address #307 PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤1,882,433.00 |
| Job Description: BUILDING 11- TYPE 1 (3 FLOORS, 32 APT. UNITS) SP-MAJ-07-06 FOR "INTEGRA WOODS" |
| Type: CN |
Contractor
LANDSOUTH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1680 THE GREENS WAY JACKSONVILLE , FL 32277 |
CBC035104 (Exp: 08/31/2010) | 386-586-0781 | 386-586-2805 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
NINO JOE PARRALES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6824 PHILLIPS PKWY DR. S JACKSONVILLE , FL 32256 |
CAC057164 (Exp: 08/31/2010) | (904)346-1774 | (904)346-4788 |
STEPHEN JOHN CHASTAIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1923 TAMPA EAST BLVD TAMPA, FL 33619 |
CFC024520 (Exp: 08/31/2012) | (813)246-5341 | (813)246-5345 |
FRED M POMAR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1025 6TH STREET DAYTONA BEACH, FL 32117 |
CCC1328140 (Exp: 08/31/2010) | (386)255-6113 | (386)254-8816 |
Inspection History
| Type | Request Date | Result | Inspector |
| COMMERCIAL BUILDING FINAL | 05/19/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/19/2009 2:10:15 PM VERIFIED FIXED HOLE IN FIRE WALL OF GARAGE AS PER GERALD HINDMAN. | |||
| COMMERCIAL BUILDING FINAL | 05/15/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 5/15/2009 3:38:26 PM FIX HOLES IN FIRE WALLS IN MIDDLE GARAGE UNIT. | |||
| ENGINEERING FINAL | 05/14/2009 | APPROVED | MCOBB |
| TRAFFIC ENGINEER | 05/14/2009 | APPROVED | MCOBB |
| LANDSCAPE FINAL | 05/14/2009 | APPROVED | WBUTLER |
| Note: A bond is on file for the remaining punch list items. Bill Butler | |||
| UTILITY COMMERCIAL FINAL | 05/12/2009 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 05/12/2009 | APPROVED | KKING |
| H.V.A.C. FINAL | 05/06/2009 | APPROVED | JHINDMAN |
| FIRE FINAL | 04/29/2009 | APPROVED | JLEWIS |
| ELECTRICAL FINAL | 04/28/2009 | APPROVED | RMARVEL |
| ELECTRICAL FINAL | 04/27/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 4/27/2009 4:03:09 PM LIGHT SWITCHES IN BEDROOMS MUST BE ON ARC FAULT CIRCUIT. NEED REVISED PLAN FOR HOUSE PANEL. | |||
| PLUMBING FINAL | 04/23/2009 | APPROVED | JHINDMAN |
| UNDERGROUND ELECTRICAL | 04/16/2009 | APPROVED | RMARVEL |
| COMMERCIAL POWER INSPECTION | 04/06/2009 | APPROVED | RMARVEL |
| UNDERGROUND ELECTRICAL | 03/24/2009 | APPROVED | JHINDMAN |
| Note: Inspection Requested at 3/23/2009 1:17:49 PM SITE LIGHTING | |||
| INSULATION INSPECTION | 02/12/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 02/11/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 2/11/2009 2:55:55 PM NOT READY. FIRE SPRINKLER LINE CUT OPEN , INSULATION BY SPRINKLER LINES IS NOT IN PLACE. | |||
| INSULATION INSPECTION | 02/10/2009 | CANCELLED BY APPLICANT | AIRS WEB |
| FRAMING | 02/05/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 2/3/2009 3:10:47 PM FINAL FRAMING | |||
| FRAMING | 02/04/2009 | CANCELLED BY APPLICANT | AIRS WEB |
| Note: THIS IS A REINSPECTION Inspection Requested at 2/3/2009 3:10:47 PM FINAL FRAMING | |||
| FRAMING | 01/28/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 1/27/2009 3:56:11 PM FINAL FRAME Inspection Resulted at 1/28/2009 2:44:45 PM FLOOR TRUSS SPACING IS NOT PER ENGINEERS DESIGN FOR OVER SPAN | |||
| SECOND ROUGH PLUMBING INSPECTION | 01/28/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| SECOND ROUGH PLUMBING INSPECTION | 01/27/2009 | CANCELLED BY APPLICANT | AIRS WEB |
| H.V.A.C. ROUGH | 01/27/2009 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| H.V.A.C. ROUGH | 01/23/2009 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/23/2009 2:39:06 PM PENATRATION THRU THE PLENUM AREA NEED TO BE SEAL AND WOOD NEEDS TO BE OUT OF AREA...ALSO WALL STUDS HAVE BEEN COMPREMISED. | |||
| LATH /BRICK FLASHING | 01/23/2009 | APPROVED | JHINDMAN |
| SECOND ROUGH PLUMBING INSPECTION | 01/09/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: partial sanitary except tubsets | |||
| H.V.A.C. ROUGH | 01/09/2009 | Disapproved -FEE REQUIRED | LWOODROME |
| Note: Inspection Resulted at 1/9/2009 3:37:10 PM NEED REVISION FOR EXAUST VENTS IN C-UNITS...NEED TO REMOVE FLAMABLE MATERIAL AND PVC PIPE FROM AIR RETURNS. | |||
| 2ND ROUGH ELECTRICAL | 01/09/2009 | APPROVED | RMARVEL |
| Note: Inspection Requested at 1/8/2009 11:19:52 AM REINSPECT | |||
| 2ND ROUGH ELECTRICAL | 01/08/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 1/8/2009 3:06:51 PM PROPERLY TORQUE LUGS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/30/2008 | PARTIALLY APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Requested at 12/29/2008 2:55:19 PM TRUSS BRACES/ENGINEERING REMAINS TO BE VIEWED. Inspection Resulted at 12/30/2008 11:36:01 AM TRUSS BRACING AND TIE-DOWN ONLY OK.......DR | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/23/2008 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/23/2008 12:57:01 PM BY JOHN | |||
| FRAMING | 12/16/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Requested at 12/15/2008 10:33:09 AM PARTIAL WINDOW SCREW Inspection Resulted at 12/16/2008 2:41:48 PM WINDOW ANCHORS | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/10/2008 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/10/2008 2:35:46 PM BY JOHN | |||
| ROOF IN PROGRESS | 12/04/2008 | APPROVED | JHINDMAN |
| FIREWALL INSPECTION | 12/02/2008 | APPROVED | JPATTEE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/02/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 12/1/2008 1:19:30 PM INSPECTION FOR CABLE ONLY Inspection Resulted at 12/2/2008 3:21:38 PM QUICK TIE CABLES AND SILL PLATE ANCHORS ONLY | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 11/26/2008 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Requested at 11/25/2008 2:17:44 PM 2ND HALF OF WALL SHEATHING INSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/20/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Requested at 11/19/2008 4:25:18 PM SHEATHING FOR DRY IN Inspection Resulted at 11/20/2008 3:20:52 PM ROOF SHEATHING ONLY | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/19/2008 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: Inspection Requested at 11/18/2008 4:47:55 PM DRY-IN ONLY Inspection Resulted at 11/19/2008 3:49:35 PM BY JOHN | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 11/19/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Requested at 11/18/2008 4:47:43 PM PARTIAL ON BREEZEWAYS AND COLUMNS Inspection Resulted at 11/19/2008 3:49:34 PM BREEZEWAYS AND BALCONYS ONLY | |||
| TEMPORARY POLE | 11/13/2008 | APPROVED | JHINDMAN |
| Note: Robin sent a note requesting this inspection Inspection Resulted at 11/13/2008 3:25:24 PM TRANSFORMER 16298 18 | |||
| TIE BEAM | 11/12/2008 | APPROVED | BBEMBRY |
| FOUNDATION SURVEY APPROVED BY ZONING | 10/10/2008 | APPROVED | DRAMIREZ |
| MONOLITHIC SLAB INSPECTION/SLAB | 09/19/2008 | APPROVED | JHINDMAN |
| FIRST ROUGH PLUMBING INSPECTION | 09/15/2008 | APPROVED | PGALLMANN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 04/21/2009 | 04/21/2009 |
| Note: Released By: SKNOPF Approved for Release. Revision: panel schedule changes. | |||
| ELEC | COMPLETE | 03/25/2009 | 03/27/2009 |
| Note: Released By: SKNOPF Approved for Release. revisions to panel schedule/site lighting circuit schedule | |||
| MECH | COMPLETE | 03/25/2009 | 03/25/2009 |
| Note: Released By: FREODICA Revision: Air handler tonage changed (Rev. 12, dated 2-23-09.) | |||
| ELEC | COMPLETE | 02/25/2009 | 02/25/2009 |
| Note: Released By: JMCGOWEN revision site lighting | |||
| BLD | COMPLETE | 02/09/2009 | 02/09/2009 |
| Note: Released By: JMCGOWEN Revision revision to stair tower/connections | |||
| BLD | COMPLETE | 02/04/2009 | 02/05/2009 |
| Note: Released By: JJOSEPH truss repair | |||
| ELEC | HOLD | 01/30/2009 | 01/30/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Integra Woods #2008040172, 2008040174, 2008040177, 2008040181, 2008040182, 2008040183, 2008040184, 2008040185, 2008040186, 2008040187, 2008040188, 2008040189, 2008040190, 2008040191, 2008040192, 2008040193, 2008040194, 2008040195, 2008040198, 2008040200, 2008040202, 2008040203, 2008040204, 2008040205 1/30/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. This plan sheet shows circuits P-1, 2, 3, 4 and 6 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. b. This plan sheet shows circuit TC-2 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. c. A total of 4000W of fixture load is shown on a 1P20A circuit breaker on circuit HP3-10. Panel schedule shows an 1100W total load for both HP3-10 and HP3-11. Revise. d. A total of 3900W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-20. Panel schedule shows a 2800W total load for 3 circuits, HP1-20, 22, and 24. Revise. e. A total of 2700W of fixture load is shown on a 1P20A circuit breaker on circuit HP2-17. Revise. f. A total of 4100W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-22. Revise. g. Circuit HP2-17 thru 19 is shown as Bldg/Site lights in panel schedule, but HP2-19 does not appear on E1.01 Site Plan. Coordinate. 2. E1.91: a. Compactor Power Riser Diagram shows #6 grounding electrode conductor for a #250 Aluminum service feeder. Revise grounding electrode conductor on this sheet per NEC Table 250.66 and Grounding Electrode Table on Sheet E6.02. b. Identify HP for garage door opener circuit S-3 and GP-1, 2. Panel shows load is only 500W per motor, which would make motor smaller than 1/4HP. Confirm HP size for motor and provide load in panel schedule per NEC Table 430.248. c. Mail Kiosk Detail 1 does not identify circuit number or which Clubhouse Panel the Mail Kiosk lighting is fed from. E6.01 Clubhouse panel schedules also do not reflect Mail Kiosk lighting. Revise. d. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L1E is 2P60A on circuit C1-2:4. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. e. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L2I is 2P60A on circuit C1-6:8. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. f. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L3 is 2P60A with a 5.7KVA load on circuit C1-10:12. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. g. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L5 is 2P60A with a 5.7KVA load on circuit C2-6:8. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. h. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L4 is 2P60A on circuit C2-35:37. Panel Schedule on E6.01 has a 2P50A circuit breaker for this unit. Resolve conflict. i. Equipment Schedule ME1.43 still shows HVAC unit PTHP1 on a 2P60A circuit breaker on C2-2:4. Panel schedule C2 now shows this circuit as blank. If PTHP1 is no longer an HVAC unit on this building, delete unit from equipment schedule and submit revised drawings. Resolve conflict. j. Revise loads for circuit GP-3, 4 which are undersized in panel schedule. 3. E6.01 and E1.01: Clarify how (1) 2P40A circuit breaker on circuit HP1-16:18 is protecting feeders to (2) MLO sub-panels, "GP" and "S", in accordance with NEC 240.21(B)(5). 4. E6.02: a. Clubhouse Service Calculation - revise loads for panels in load calculation to match Demand Loads calculated in Panel Schedules on Sheet E6.01. b. Indicate which House Panel is associated with each Load Calculation for Meter Centers A & B, Bldg. Types 1, 2, and 3. Also indicate building number where each Meter Center is located. c. Revise Demand Load Calculations for Meter Centers A & B, Buildings 1, 2, and 3 to reflect Demand Load, not Connected Loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 01/29/2009 | 01/30/2009 |
| Note: Released By: JJOSEPH Revision Truss repair | |||
| MECH | COMPLETE | 01/27/2009 | 01/29/2009 |
| Note: Released By: FREODICA Revision: Specs for washers/dryers in B1, C1, & D units. | |||
| BLD | COMPLETE | 01/26/2009 | 01/26/2009 |
| Note: Released By: JJOSEPH revision screen enclosure submittals and location | |||
| PLLA | COMPLETE | 01/21/2009 | 01/22/2009 |
| Note: Released By: WBUTLER | |||
| ELEC | HOLD | 01/21/2009 | 01/21/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008040194 (Integra Woods Bldg 11 Type 1 @ 555 Shady Oaks Dr.) 1/21/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. Information on Sheet E1.01 regarding Electrical service feeders from FPL transformers has been deleted from this plan sheet. Reinsert this information back on this sheet. b. Identify panel circuits on plan sheet and provide revised House panel schedules with updated load calculations. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| PLUM | COMPLETE | 01/08/2009 | 01/08/2009 |
| Note: Released By: FREODICA REVISION: Revised Riser diagrams 1S and 1SA- kitchen sinks from 2" to 1-1/2". | |||
| PLUM | COMPLETE | 12/19/2008 | 12/22/2008 |
| Note: Released By: FREODICA Revision: Sealed letter concerning washer location. | |||
| PLUM | COMPLETE | 12/19/2008 | 12/19/2008 |
| Note: Released By: FREODICA Revision: Sealed letter concerning bathtub models (BT-2, BT-1). | |||
| BLD | COMPLETE | 12/18/2008 | 12/18/2008 |
| Note: Released By: JJOSEPH Revision: Applying Simpson RPS28 Straps. | |||
| BLD | COMPLETE | 12/18/2008 | 12/18/2008 |
| Note: Released By: FREODICA Revision: 1. Revised clothes dryer exhaust vent and bathroom exhaust layouts for Units C1 and D. | |||
| BLD | COMPLETE | 12/12/2008 | 12/12/2008 |
| Note: Released By: JJOSEPH Revision:- clarification / modification of a quick tip 3rd floor vault area only | |||
| PLUM | COMPLETE | 12/08/2008 | 12/08/2008 |
| Note: Released By: FREODICA Revision: Plumbing revision 7 dated 11-26-08. | |||
| BLD | COMPLETE | 11/24/2008 | 11/24/2008 |
| Note: Released By: JJOSEPH Revision Web removal for AC chase | |||
| ZON | CANCEL | 11/19/2008 | |
| BLD | COMPLETE | 11/06/2008 | 11/06/2008 |
| Note: Released By: JMCGOWEN revison for trusses | |||
| BLD | COMPLETE | 10/22/2008 | 10/24/2008 |
| Note: Released By: JJOSEPH Revision Third floor: Removal of columns, cap and flashing details cabinet change/shelving change | |||
| PLUM | HOLD | 10/22/2008 | 10/24/2008 |
| Note: Held By: FREODICA Revision: Plans shall be signed and sealed by FL. Reg. Engr. | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION Roofing submittals | |||
| BLD | COMPLETE | 10/22/2008 | 10/23/2008 |
| Note: Released By: JJOSEPH REVISION code compliant Hardware | |||
| DSD | HOLD | 10/02/2008 | 10/06/2008 |
| Note: Held By: DRAMIREZ Architectural plans need to be modified. On hold until modification is approved. | |||
| BLD | COMPLETE | 09/22/2008 | 09/22/2008 |
| Note: Released By: JMONTARULI released by: J Joseph Anchor placement plans that show anchor spacing for all bearing walls | |||
| BLD | COMPLETE | 09/15/2008 | 09/22/2008 |
| Note: Released By: JJOSEPH Anchor placement plans that show anchor spacing for all bearing walls REVISION | |||
| FI1 | COMPLETE | 07/11/2008 | 07/14/2008 |
| Note: Released By: JPATTEE | |||
| FI1 | HOLD | 07/02/2008 | 07/11/2008 |
| Note: Held By: JPATTEE Sheet A5.01 not attached | |||
| ELEC | COMPLETE | 04/11/2008 | 04/11/2008 |
| Note: Released By: SKNOPF Approved for Release. | |||
| FI1 | HOLD | 04/11/2008 | 05/06/2008 |
| Note: Held By: JPATTEE 1) Plans do not provide design criteria for automatic fire sprinkler system(s) 2) Unable to locate detail for the rated garage wall and rated floor ceiling.Ok JDP | |||
| MECH | COMPLETE | 04/11/2008 | 04/11/2008 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 04/11/2008 | 04/11/2008 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 04/09/2008 | 04/11/2008 |
| Note: Released By: FREODICA | |||
| DSD | COMPLETE | 10/24/2008 | |
| Note: Released By: DRAMIREZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/19/2009 |
| REINSPECTION FEE | ¤40.00 | 05/19/2009 |
| REINSPECTION FEE | ¤40.00 | 05/19/2009 |
| REINSPECTION FEE | ¤40.00 | 05/19/2009 |
| REINSPECTION FEE | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REVISION | ¤40.00 | 05/19/2009 |
| REINSPECTION FEE | ¤40.00 | 05/06/2009 |
| REINSPECTION FEE | ¤40.00 | 05/06/2009 |
| REVISION | ¤40.00 | 01/27/2009 |
| PLAN CHECK FEE | ¤3,786.95 | 07/22/2008 |
| PARKS IMPACT FEE 4/01/08 | ¤39,347.20 | 07/22/2008 |
| PLUMBING FEE | ¤2,005.80 | 07/22/2008 |
| BUILDING CODE ADMIN FUND | ¤213.47 | 07/22/2008 |
| FIRE IMPACT FEE RES 4/01/08 | ¤6,089.28 | 07/22/2008 |
| ELECTRIC FEE | ¤2,005.80 | 07/22/2008 |
| MECHANICAL FEE | ¤2,005.80 | 07/22/2008 |
| PERMIT FEE | ¤18,131.50 | 07/22/2008 |
| RADON FEE | ¤213.47 | 07/22/2008 |
| SCHOOL BOARD IMPACT FEE MULTI | ¤29,792.00 | 07/22/2008 |
| 10/07 TRANS MULTI - FAMILY | ¤71,243.20 | 07/22/2008 |
| 10/07 TRANS MULTI - FAMILY | ¤71,243.20 | 07/18/2008 |
| BUILDING CODE ADMIN FUND | (¤213.47) | 07/18/2008 |
| 10/07 TRANS MULTI - FAMILY | (¤71,243.20) | 07/18/2008 |
| RADON FEE | ¤213.47 | 07/18/2008 |
| SCHOOL BOARD IMPACT FEE MULTI | ¤29,792.00 | 07/18/2008 |
| SCHOOL BOARD IMPACT FEE MULTI | (¤29,792.00) | 07/18/2008 |
| PERMIT FEE | ¤18,131.50 | 07/18/2008 |
| PARKS IMPACT FEE 4/01/08 | ¤39,347.20 | 07/18/2008 |
| PARKS IMPACT FEE 4/01/08 | (¤39,347.20) | 07/18/2008 |
| PERMIT FEE | (¤18,131.50) | 07/18/2008 |
| FIRE IMPACT FEE RES 4/01/08 | (¤6,089.28) | 07/18/2008 |
| FIRE IMPACT FEE RES 4/01/08 | ¤6,089.28 | 07/18/2008 |
| MECHANICAL FEE | ¤2,005.80 | 07/18/2008 |
| MECHANICAL FEE | (¤2,005.80) | 07/18/2008 |
| BUILDING CODE ADMIN FUND | ¤213.47 | 07/18/2008 |
| ELECTRIC FEE | ¤2,005.80 | 07/18/2008 |
| ELECTRIC FEE | (¤2,005.80) | 07/18/2008 |
| RADON FEE | (¤213.47) | 07/18/2008 |
| PLAN CHECK FEE | (¤3,786.95) | 07/18/2008 |
| PLAN CHECK FEE | ¤3,786.95 | 07/18/2008 |
| PLUMBING FEE | ¤2,005.80 | 07/18/2008 |
| PLUMBING FEE | (¤2,005.80) | 07/18/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤175,954.47 |