I want to search for...

Permit #2008040205

Permit Details

Status: COED

Parcel Id: 31-12-31-5371-00000-0040
CONDITIONED SPACE: 1816 sqft
GARAGE: 1968 sqft
OPENED PORCH (WITH ROOF) : 182 sqft
OPENED PORCH (WITH ROOF) : 275 sqft
Total Square Footage: 4241 sqft
Block: 00000
Subdivision: 2138 - SEMINOLE POINTE SUBDIVISION
Job Phone: 386-586-0781
Location Address: 745 SHADY OAKS DR
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 08/15/2008
NOC: RECORDED
Applicant name: JAMES G PYLE
Owner: PALM COAST SEMINOLE GROUP LLC 1 FLORIDA PARK DRIVE

Address

#307

PALM COAST, FL 32137

Lot: 0040
Contracted Stated Job Value: ¤174,714.00
Job Description: BUILDING 30- TYPE 3 A (2 FLOORS, 2 APT. UNITS) SP-MAJ-07-06 FOR "INTEGRA WOODS"
Type: CN

Contractor

LANDSOUTH CONSTRUCTION LLC
Status Location Address State License Number Phone Fax
CANCEL

1680 THE GREENS WAY

JACKSONVILLE , FL 32277

CBC035104 (Exp: 08/31/2010) 386-586-0781 386-586-2805

Sub Contractors

RANCE F BORDERICK
Status Location Address State License Number Phone Fax
ACTIVE

430 WEST DRIVE

ALTAMONTE SPRINGS, FL 32714

EC0000981 (Exp: 08/31/2026) (407)788-3500 407-788-2007
NINO JOE PARRALES
Status Location Address State License Number Phone Fax
CANCEL

6824 PHILLIPS PKWY DR. S

JACKSONVILLE , FL 32256

CAC057164 (Exp: 08/31/2010) (904)346-1774 (904)346-4788
STEPHEN JOHN CHASTAIN
Status Location Address State License Number Phone Fax
CANCEL

1923 TAMPA EAST BLVD

TAMPA, FL 33619

CFC024520 (Exp: 08/31/2012) (813)246-5341 (813)246-5345
FRED M POMAR
Status Location Address State License Number Phone Fax
CANCEL

1025 6TH STREET

DAYTONA BEACH, FL 32117

CCC1328140 (Exp: 08/31/2010) (386)255-6113 (386)254-8816

Inspection History

Type Request Date Result Inspector
COMMERCIAL BUILDING FINAL 06/29/2009 FINAL APPROVED JHINDMAN
LANDSCAPE FINAL 06/22/2009 APPROVED - AS NOTED WBUTLER
Note: Landscape final approved however a punch list has been submitted and bonded that must be completed prior to the last building c.o. and prior to the release of the bond.
ENGINEERING FINAL 06/18/2009 APPROVED MCOBB
TRAFFIC ENGINEER 06/18/2009 APPROVED MCOBB
UTILITY COMPANY FINAL 06/15/2009 APPROVED KKING
UTILITY COMMERCIAL FINAL 06/12/2009 APPROVED KKING
H.V.A.C. FINAL 04/29/2009 APPROVED JHINDMAN
ELECTRICAL FINAL 04/29/2009 APPROVED RMARVEL
ELECTRICAL FINAL 04/28/2009 CANCELLED BY APPLICANT AIRS WEB
FIRE FINAL 04/24/2009 APPROVED JPATTEE
PLUMBING FINAL 04/23/2009 APPROVED JHINDMAN
COMMERCIAL POWER INSPECTION 04/17/2009 APPROVED RMARVEL
INSULATION INSPECTION 03/06/2009 APPROVED JHINDMAN
LATH /BRICK FLASHING 03/03/2009 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Requested at 3/2/2009 10:57:33 AM LATHE / FELT PAPER
SECOND ROUGH PLUMBING INSPECTION 03/02/2009 CANCELLED BY APPLICANT AIRS WEB
Note: Inspection Requested at 2/27/2009 1:43:23 PM WATER AND TUBS
FRAMING 03/02/2009 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 02/27/2009 CANCELLED BY APPLICANT JHINDMAN
Note: Kelly called in this inspection Inspection Resulted at 2/27/2009 3:23:41 PM CANCELLED BY JOHN
SECOND ROUGH PLUMBING INSPECTION 02/27/2009 APPROVED JHINDMAN
FRAMING 02/26/2009 CANCELLED BY APPLICANT JHINDMAN
H.V.A.C. ROUGH 02/06/2009 APPROVED JHINDMAN
2ND ROUGH ELECTRICAL 01/08/2009 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
2ND ROUGH ELECTRICAL 01/07/2009 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 1/7/2009 3:15:10 PM TORQUE LUGS IN PANEL.
FRAMING 12/31/2008 APPROVED DROCKWELL
Note: Inspection Requested at 12/30/2008 4:36:49 PM WINDOW SCREW INSPECTION Inspection Resulted at 12/31/2008 3:17:32 PM WINDOW FRAME SCREW PATTERN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/29/2008 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Requested at 12/23/2008 4:08:48 PM TRUSS BRACES/ENGINEERING REMAINS TO BE VIEWED. Inspection Resulted at 12/29/2008 3:14:07 PM TRUSS ENGINNERING AND BRACING OK.....DR
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/16/2008 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Requested at 12/15/2008 2:38:16 PM QUICK TIE CABLES Inspection Resulted at 12/16/2008 2:41:50 PM CABLE TIES ONLY
ROOF IN PROGRESS 12/15/2008 APPROVED JHINDMAN
Note: Inspection Requested at 12/12/2008 12:11:26 PM DRY IN
TEMPORARY POLE 12/04/2008 APPROVED JHINDMAN
Note: Inspection Resulted at 12/4/2008 2:01:26 PM CALLED FPL 2:00 P.M.
EXTERIOR WALL SHEATHING/SHEAR WALL 12/03/2008 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/26/2008 PARTIALLY APPROVED CMINI
Note: Inspection Requested at 11/25/2008 2:21:11 PM PARTIAL ROOF SHEATHING ONLY FOR DRY IN Inspection Resulted at 11/26/2008 3:34:19 PM NAIL PATTERN ONLY OK TO DRY IN.
EXTERIOR WALL SHEATHING/SHEAR WALL 11/26/2008 PARTIALLY APPROVED CMINI
Note: Inspection Requested at 11/25/2008 6:34:13 PM PARTIAL, TO CLOSE INSPECTION HOLES Inspection Resulted at 11/26/2008 3:34:19 PM COLUMN TIE DOWNS AND BREEZE WAY SHEATHING ONLY.
FOUNDATION SURVEY APPROVED BY ZONING 11/21/2008 APPROVED DRAMIREZ
TIE DOWN 11/12/2008 APPROVED BBEMBRY
Note: letter submitted from engineer regarding the quick tie cables
MONOLITHIC SLAB INSPECTION/SLAB 10/06/2008 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 09/24/2008 APPROVED PGALLMANN

Review History

Department Status Date In Date Out
ELEC COMPLETE 04/21/2009 04/21/2009
Note: Released By: SKNOPF Approved for Release. Revision: panel schedule changes.
ELEC COMPLETE 03/25/2009 03/25/2009
Note: Released By: SKNOPF Approved for Release. Added Site lighting, revised panel schedules, added building identification.
MECH COMPLETE 03/25/2009 03/25/2009
Note: Released By: FREODICA Revision: Air handler tonage changed (Rev. 12, dated 2-23-09.)
PLLA COMPLETE 03/25/2009 03/26/2009
Note: Released By: ECOYNE per Bill Butler
ELEC HOLD 01/30/2009 01/30/2009
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Integra Woods #2008040172, 2008040174, 2008040177, 2008040181, 2008040182, 2008040183, 2008040184, 2008040185, 2008040186, 2008040187, 2008040188, 2008040189, 2008040190, 2008040191, 2008040192, 2008040193, 2008040194, 2008040195, 2008040198, 2008040200, 2008040202, 2008040203, 2008040204, 2008040205 1/30/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. This plan sheet shows circuits P-1, 2, 3, 4 and 6 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. b. This plan sheet shows circuit TC-2 for unknown type and quantities of landscape lights. Identify lighting fixtures and provide fixture locations on site plan. Identify Fixture loads and voltage for Load Calculation verification. c. A total of 4000W of fixture load is shown on a 1P20A circuit breaker on circuit HP3-10. Panel schedule shows an 1100W total load for both HP3-10 and HP3-11. Revise. d. A total of 3900W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-20. Panel schedule shows a 2800W total load for 3 circuits, HP1-20, 22, and 24. Revise. e. A total of 2700W of fixture load is shown on a 1P20A circuit breaker on circuit HP2-17. Revise. f. A total of 4100W of fixture load is shown on a 1P20A circuit breaker on circuit HP1-22. Revise. g. Circuit HP2-17 thru 19 is shown as Bldg/Site lights in panel schedule, but HP2-19 does not appear on E1.01 Site Plan. Coordinate. 2. E1.91: a. Compactor Power Riser Diagram shows #6 grounding electrode conductor for a #250 Aluminum service feeder. Revise grounding electrode conductor on this sheet per NEC Table 250.66 and Grounding Electrode Table on Sheet E6.02. b. Identify HP for garage door opener circuit S-3 and GP-1, 2. Panel shows load is only 500W per motor, which would make motor smaller than 1/4HP. Confirm HP size for motor and provide load in panel schedule per NEC Table 430.248. c. Mail Kiosk Detail 1 does not identify circuit number or which Clubhouse Panel the Mail Kiosk lighting is fed from. E6.01 Clubhouse panel schedules also do not reflect Mail Kiosk lighting. Revise. d. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L1E is 2P60A on circuit C1-2:4. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. e. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L2I is 2P60A on circuit C1-6:8. Panel Schedule on E6.01 has a 2P35A circuit breaker for this unit. Resolve conflict. f. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L3 is 2P60A with a 5.7KVA load on circuit C1-10:12. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. g. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L5 is 2P60A with a 5.7KVA load on circuit C2-6:8. Panel Schedule on E6.01 has a 2P50A circuit breaker with a 6.6KVA load for this unit. Resolve conflict. h. Equipment Schedule on ME1.43 shows circuit breaker size for CU-L4 is 2P60A on circuit C2-35:37. Panel Schedule on E6.01 has a 2P50A circuit breaker for this unit. Resolve conflict. i. Equipment Schedule ME1.43 still shows HVAC unit PTHP1 on a 2P60A circuit breaker on C2-2:4. Panel schedule C2 now shows this circuit as blank. If PTHP1 is no longer an HVAC unit on this building, delete unit from equipment schedule and submit revised drawings. Resolve conflict. j. Revise loads for circuit GP-3, 4 which are undersized in panel schedule. 3. E6.01 and E1.01: Clarify how (1) 2P40A circuit breaker on circuit HP1-16:18 is protecting feeders to (2) MLO sub-panels, "GP" and "S", in accordance with NEC 240.21(B)(5). 4. E6.02: a. Clubhouse Service Calculation - revise loads for panels in load calculation to match Demand Loads calculated in Panel Schedules on Sheet E6.01. b. Indicate which House Panel is associated with each Load Calculation for Meter Centers A & B, Bldg. Types 1, 2, and 3. Also indicate building number where each Meter Center is located. c. Revise Demand Load Calculations for Meter Centers A & B, Buildings 1, 2, and 3 to reflect Demand Load, not Connected Loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
MECH COMPLETE 01/27/2009 01/29/2009
Note: Released By: FREODICA Revision: Specs for dryers in A2 units.
BLD COMPLETE 01/26/2009 01/26/2009
Note: Released By: JJOSEPH screeen enclosure submittals and locations
PLLA COMPLETE 01/21/2009 01/22/2009
Note: Released By: WBUTLER
ELEC HOLD 01/21/2009 01/21/2009
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008040205 (Integra Woods Bldg 30 Type 3A @ 745 Shady Oaks Dr.) 1/21/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E1.01: a. Information on Sheet E1.01 regarding Electrical service feeders from FPL transformers has been deleted from this plan sheet. Reinsert this information back on this sheet. b. Identify panel circuits on plan sheet and provide revised House panel schedules with updated load calculations. c. Identify Bldg # on Site Plan for Building #30. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD COMPLETE 12/18/2008 12/18/2008
Note: Released By: JJOSEPH Revision: Applying Simpson RPS28 Straps.
PLUM COMPLETE 12/08/2008 12/08/2008
Note: Released By: FREODICA Revision: Plumbing revision 7, dated 11-26-08.
ZON CANCEL 11/19/2008
BLD COMPLETE 11/06/2008 11/06/2008
Note: Released By: JMCGOWEN rvision trusses
FD1 CANCEL 10/24/2008
Note: correction
PLUM HOLD 10/22/2008 10/23/2008
Note: Held By: FREODICA REVISION 1. Provide (2) sets of plumbing plans, signed and sealed by FL. Registered Engineer.
BLD COMPLETE 10/22/2008 10/23/2008
Note: Released By: JJOSEPH REVISION code compliant Hardware
BLD COMPLETE 09/22/2008 09/22/2008
Note: Released By: JMONTARULI Released by: J Joseph Anchor placement plans that show anchor spacing for all bearing walls
BLD COMPLETE 09/15/2008 09/22/2008
Note: Released By: JJOSEPH Anchor placement plans that show anchor spacing for all bearing walls REVISION
FI1 COMPLETE 07/02/2008 07/11/2008
Note: Released By: JPATTEE
ELEC COMPLETE 04/11/2008 04/11/2008
Note: Released By: SKNOPF Approved for Release.
FI1 HOLD 04/11/2008 05/06/2008
Note: Held By: JPATTEE 1) Plans do not provide design criteria for automatic fire sprinkler system(s) 2) Unable to locate detail for the rated garage wall and rated floor ceiling.Ok JDP 3) Sheet A1.32 Detail #1, Is the ridge vent directly over stiarwell fire walls?
MECH COMPLETE 04/10/2008 04/11/2008
Note: Released By: JJOSEPH
PLUM COMPLETE 04/10/2008 04/11/2008
Note: Released By: JJOSEPH
BLD COMPLETE 04/09/2008 04/11/2008
Note: Released By: JJOSEPH

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤60.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REVISION ¤40.00 06/29/2009
REINSPECTION FEE ¤40.00 01/27/2009
10/07 TRANS MULTI - FAMILY ¤4,452.70 08/15/2008
PLUMBING FEE ¤186.60 08/15/2008
RADON FEE ¤21.21 08/15/2008
SCHOOL BOARD IMPACT FEE MULTI ¤1,862.00 08/15/2008
PARKS IMPACT FEE 4/01/08 ¤2,459.20 08/15/2008
PERMIT FEE ¤1,435.50 08/15/2008
PLAN CHECK FEE ¤300.15 08/15/2008
ADMIN FEE ¤20.00 08/15/2008
ELECTRIC FEE ¤186.60 08/15/2008
BUILDING CODE ADMIN FUND ¤21.21 08/15/2008
FIRE IMPACT FEE RES 4/01/08 ¤380.58 08/15/2008
MECHANICAL FEE ¤186.60 08/15/2008
MECHANICAL FEE ¤186.60 07/18/2008
PERMIT FEE ¤1,435.50 07/18/2008
PERMIT FEE (¤1,435.50) 07/18/2008
MECHANICAL FEE (¤186.60) 07/18/2008
ELECTRIC FEE (¤186.60) 07/18/2008
ELECTRIC FEE ¤186.60 07/18/2008
FIRE IMPACT FEE RES 4/01/08 ¤380.58 07/18/2008
FIRE IMPACT FEE RES 4/01/08 (¤380.58) 07/18/2008
ADMIN FEE ¤20.00 07/18/2008
BUILDING CODE ADMIN FUND ¤21.21 07/18/2008
BUILDING CODE ADMIN FUND (¤21.21) 07/18/2008
PLUMBING FEE (¤186.60) 07/18/2008
PARKS IMPACT FEE 4/01/08 (¤2,459.20) 07/18/2008
PARKS IMPACT FEE 4/01/08 ¤2,459.20 07/18/2008
PLAN CHECK FEE ¤300.15 07/18/2008
PLAN CHECK FEE (¤300.15) 07/18/2008
SCHOOL BOARD IMPACT FEE MULTI ¤1,862.00 07/18/2008
SCHOOL BOARD IMPACT FEE MULTI (¤1,862.00) 07/18/2008
10/07 TRANS MULTI - FAMILY (¤4,452.70) 07/18/2008
ADMIN FEE (¤20.00) 07/18/2008
PLUMBING FEE ¤186.60 07/18/2008
RADON FEE ¤21.21 07/18/2008
RADON FEE (¤21.21) 07/18/2008
10/07 TRANS MULTI - FAMILY ¤4,452.70 07/18/2008
Fees Total Due: ¤0.00 Total Paid: ¤11,972.35