I want to search for...

Permit #2008050431

Permit Details

Status: COED

Parcel Id: 38-11-31-7103-000E0-0000
Block: 000E0
Subdivision: 2258 - HARBORSIDE INN/PALM COAST RESORT
Job Phone: (904)223-4050
Location Address: 146 PALM COAST RESORT BLVD BLDG E
Type: CPO - COMMERCIAL POOL
Issue Date: 06/02/2008
NOC: RECORDED
Applicant name: JOHN S CLARKSON
Owner: WELLS, DOUGLAS R & PATRICIA L

Address

16 LAKELAND RD

STATEN ISLAND, NY 10314

Lot: 0000
Contracted Stated Job Value: ¤200,000.00
Job Description: POOL & SPA FOR THE HARBORSIDE INN (PALM COAST RESORT) - SP-MAJ-05-04
Type: CN

Contractor

POOLS BY JOHN CLARKSON, INC
Status Location Address State License Number Phone Fax
INACTIVE

600 ST. JOHNS BLUFF ROAD NORTH

JACKSONVILLE, FL 32225

CPC009595 (Exp: 08/31/2020) (904)223-4050 (904)223-0735

Sub Contractors

BOB BELL
Status Location Address State License Number Phone Fax
CANCEL

20 UTILITY DRIVE

PALM COAST, FL 32137

13878 (Exp: 08/31/2012) (386)437-4404 (386)446-2191
DAVID THOMAS PRUETTE
Status Location Address State License Number Phone
ACTIVE

331-8 PARKRIDGE AVE

ORANGE PARK , FL 32065

EC0002923 (Exp: 08/31/2026) 904-272-7225

Inspection History

Type Request Date Result Inspector
LANDSCAPE FINAL 11/21/2008 FINAL APPROVED WBUTLER
Note: THIS IS A REINSPECTION
POOL - FINAL 11/20/2008 CANCELLED BY APPLICANT AIRS WEB
POOL - FINAL 11/20/2008 FINAL APPROVED JHINDMAN
LANDSCAPE FINAL 10/10/2008 PARTIALLY APPROVED WBUTLER
Note: per request of wes
ELEC & ALARM 10/07/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 10/07/2008 APPROVED TSCHWEERS
Note: THIS IS A REINSPECTION Gravity ok, no permit to sign.
ENGINEERING FINAL 10/07/2008 APPROVED MCOBB
UTILITY COMPANY FINAL 09/24/2008 Disapproved - NO FEE TSCHWEERS
Note: Gravity Failes. Sewer clean out not constructed with approved pipe for our system.
GAS ROUGH 09/24/2008 APPROVED PGALLMANN
ELEC & ALARM 09/24/2008 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 9/24/2008 3:34:09 PM BURIAL DEPTH FOR THE LFNC-B CONDUIT NEEDS TO BE 18IN DEEP TO THE TOP OF THE CONDUIT.
FOUNDATION SURVEY APPROVED BY ZONING 09/16/2008 APPROVED DRAMIREZ
Note: Foundation survey for pool is approved (per Constance).
POOL DECK INSPECTION 08/07/2008 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
POOL DECK INSPECTION 07/25/2008 Disapproved -FEE REQUIRED JMCGOWEN
Note: Carla called to schedule this inspection for 7/25/08 all underground plumbing must have test pressure , bond wire needs to be uncovered , grade needs to be to final grade around deck area, need to identify wet niche conduit sealing material. not ready
STEEL & GROUND 06/24/2008 APPROVED JLEVRAULT
Note: Requested by Lawrence

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 05/22/2008 05/27/2008
Note: Released By: DMAY
ZON COMPLETE 05/21/2008 05/22/2008
Note: Released By: BBARTON
BLD HOLD 05/27/2008
Note: Held By: JJOSEPH 1.Provide Bathing loads ( maximum number of personns allowed in the pool at the same time or ). using the pool capacity( GPM) or filter rate for the computationj 2. Provide concrete pool depths details including permanent depth markings. 3. Need to submit Equipotential Bonding details according to NEC 2005 section 250.130. 4. A gas permit est required before releasing the pool permit if a spa using gas heater will be constructed. 5. According to the Florida Building code 2006, section 424.1.4.2, artificial ligthing shall be provided at the swimming pool. 5. Need to submit two separate permit.( Building and Pool )
BLD COMPLETE 05/28/2008
Note: Released By: JJOSEPH

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/19/2008
REINSPECTION FEE ¤40.00 08/11/2008
ADMIN FEE ¤20.00 06/02/2008
ELECTRIC FEE ¤150.00 06/02/2008
PERMIT FEE ¤1,400.00 06/02/2008
PLAN CHECK FEE ¤230.00 06/02/2008
Fees Total Due: ¤0.00 Total Paid: ¤1,880.00