Job Description: UNIT 19 - ADD (2) WALLS & KITCHEN EQUIPMENT/FLOORING FOR "COLLETTI'S ITALIAN DELI - NO SEATING
Type: CN

Contractor

MACHIN CONSTRUCTION CO
Status Location Address State License Number Phone Fax
INACTIVE

3 HARGROVE GRADE SUITE 1

Palm Coast, FL 32137

CGC058789 (Exp: 08/31/2024) (386) 445-4350 (386)446-5459

Sub Contractors

ROBERT J CATES
Status Location Address State License Number Phone Fax
CANCEL

1750 RIDGEWOOD AVE

HOLLY HILL, FL 32117

EC13002452 (Exp: 08/31/2014) 386-677-4757 386-677-8686
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 10/31/2008 FINAL APPROVED LWOODROME
Note: Adminstrative work to close permit. Building Final previously approved.
COMMERCIAL BUILDING FINAL 10/30/2008 APPROVED JHINDMAN
FIRE FINAL 10/30/2008 APPROVED JPATTEE
ELECTRICAL FINAL 10/29/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
PLUMBING FINAL 10/27/2008 APPROVED - AS NOTED JMCGOWEN
Note: Inspection Resulted at 10/27/2008 3:21:41 PM NEED TO HAVE RIGHT HAND FLUSH TANK FOR BATH ROOM.CHECK ON BUILDING FINAL.
ABOVE CEILING 10/27/2008 APPROVED - AS NOTED JMCGOWEN
Note: Rick called this inspection in Inspection Resulted at 10/27/2008 3:21:41 PM STRAP FLEX A/C IN HALLWAY.
ELECTRICAL FINAL 10/27/2008 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 10/27/2008 3:13:56 PM NEED REVISIONS AS WAS POINTED OUT TO CONTRACTOR. CANNOT ALTER COVER PLATES. NEED TO INSTALL ARC SHIELDS ON RECEPTACLES WHERE THEY DONOT MEET MIN CODE STANDARDS FOR COMBUSTIBLE AND NON COMBUSTIBLE MATERIAL. STRAP FLEX DUCT ON A/C.
SECOND ROUGH PLUMBING INSPECTION 10/01/2008 APPROVED PGALLMANN
2ND ROUGH ELECTRICAL 10/01/2008 APPROVED RMARVEL
FRAMING 10/01/2008 APPROVED CMINI
UTILITY COMMERCIAL FINAL 09/29/2008 APPROVED KKING
UTILITY COMPANY FINAL 09/29/2008 APPROVED KKING
Note: Rick from Machin called, he said utility told him to schedule both these finals at the same time
FIRST ROUGH PLUMBING INSPECTION 09/25/2008 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 09/19/2008 Disapproved - NO FEE PGALLMANN
Note: Locked up building around 4 pm. couldn't inspect

Review History

Department Status Date In Date Out
ELEC HOLD 10/28/2008 10/29/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008070469 (Colletti's Italian Deli @ 5 Utility Dr.) 10/29/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Revised panel schedule circuits no longer match circuit identification on Floor Power Plan. Provide revised Power Plan to match revised panel schedule submitted. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD COMPLETE 09/09/2008 09/09/2008
Note: Released By: JJOSEPH Revised plan per J. Joseph
BLD HOLD 09/08/2008 09/08/2008
Note: Held By: JJOSEPH Please , the floor plan needs to match on both pages.
UD1 COMPLETE 09/04/2008 09/05/2008
Note: Released By: CJOHNSON
ELEC COMPLETE 09/03/2008 09/04/2008
Note: Released By: SKNOPF Approved for Release.
MECH COMPLETE 09/03/2008 09/03/2008
Note: Released By: FREODICA Response to your hold
PLUM COMPLETE 09/03/2008 09/03/2008
Note: Released By: FREODICA
UD1 HOLD 08/04/2008 08/06/2008
Note: Held By: CJOHNSON 1. All floor drains and sinks in the food preparation and food service areas shall be plumbed to a grease interceptor. A minimum of 750 gallon unit will be required. Grease interceptor specifications can be found on the City web site http://www.ci.palm-coast.fl.us/Government/Departments/Utilities/Standards.aspx 2. Additional capacity fees will be required. Contact Utility Department at 986-2355 regarding fees.
ELEC HOLD 08/01/2008 08/01/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008070469 (Coletti's Italian Deli @ 5 Utility Dr. Unit 19) 8/1/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Sheet 1 of 2: a. Provide Service Demand Load Calculations for this unit. b. Panel Schedule shows circuit 26 is used for Oven (24:26), as well as Water Heater (26:28). Revise circuitry. c. Circuit 30:32 Hot Table in panel shows 2 circuits, but circuit breaker is given as 1P30A. Revise. Confirm that this circuit listed as "Hot Table" in panel schedule is same as item shown as "Steam Table" on Floor Plan, otherwise add circuit in panel for "Steam Table". d. Identify all circuits on Floor Plan for all devices. e. Identify conductor size for Service feeder to this Unit. f. There are still some convenience outlets located in Food Prep areas that are not shown as GFCI per NEC 210.8(B)(2). Revise. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
FI1 COMPLETE 08/01/2008 08/04/2008
Note: Released By: JPATTEE Will stamp plans upon satisfaction of building, electrical and mechanical comments. JDP
PLUM HOLD 07/31/2008 07/31/2008
Note: Held By: FREODICA 1. Provide separate vent for 2" hub drain as the distance from a fixture trap to a vent has exceeded the maximum allowed by code. See FBC/Plumbing 2004 Table 906.1. Revise sanitary riser diagram to reflrect the change. 2. Clarify the notes stating " For new plumbing in existing wall, provide FIRE DAMPERS around pipes for zero penetrations." 3. Provide Plumbing Fixture Schedule. 4. Provide Domestic Water Riser Diagram. 5. Indicate on plan that the space (merchandise space) will not be provided with seats for dining. This arrangement will qualify for exception for a separate toilet facility per FBC/Plumbing 2004 section 403.2 exception 2.
MECH HOLD 07/31/2008 07/31/2008
Note: Held By: FREODICA 1. Provide a separate permit application for kitchen exhaust hood. 2. Clarify Venting Detail (Exhaust Fan). Where would this be applied to? Provide location on plan and how much air it is exhauting. 3. Provide information on the existing HVAC system showing by calculations that it would be sufficient to meet the required outdoor ventilation air for the new occupancy per FBC/Mechanical 2004 Table 403.3 and energy calculations. 4. Provide HVAC contractor in the permit application.
BLD HOLD 07/30/2008 07/31/2008
Note: Held By: JJOSEPH 1.The toilet door cannot be opened to the Kitchen Area, please change the door location. 2. The food display must be accessible then, provide the elevation details. 3.Revise occupant load calculation.
ZON COMPLETE 07/29/2008 07/29/2008
Note: Released By: BBARTON received letter stating No Seating Area
ZON HOLD 07/28/2008 07/28/2008
Note: Held By: BBARTON verifying use verifying parking please clarify in writing if there is to be seating area spoke with contractor who stated there was not any seating area and he will fax a letter over stating this. NO RESTAURANT/SEATING AREA PERMITTED IN THIS UNIT
BLD HOLD 09/03/2008
Note: Held By: JJOSEPH 1.Revise the new partion wall location to comply to the toilet access as per section 11-4.13.6 or figure 25 of the Florida Building code. 2. The saloon door is not accessible by code.
ELEC CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/28/2008
SITE PLAN 20 ¤20.00 09/11/2008
ADMIN COMMERCIAL ¤60.00 09/11/2008
ELECTRIC FEE ¤72.00 09/11/2008
FIRE PLANS REVIEW ¤25.00 09/11/2008
PERMIT FEE ¤140.00 09/11/2008
PLAN CHECK FEE ¤100.00 09/11/2008
PLUMBING FEE ¤72.00 09/11/2008
Fees Total Due: ¤0.00 Total Paid: ¤529.00