I want to search for...

Permit #2008090180

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00650-0040
CONDITIONED SPACE: 1906 sqft
GARAGE: 440 sqft
OPENED PORCH (WITH ROOF) : 117 sqft
OPENED PORCH (WITH ROOF) : 63 sqft
Total Square Footage: 2526 sqft
Block: 00650
Subdivision: -
Job Phone: (386)437-3323
Location Address: 8 ROCKING HORSE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/01/2008
NOC: RECORDED
Applicant name: PETER JOSEPH LYDEN
Owner: KLEINHANS WILLIAM J

Address

7 VISTA SHORES DRIVE

UNION BEACH, NJ 07735

Lot: 0040
Contracted Stated Job Value: ¤192,900.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

DEL CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

PO BOX 1009

BUNNELL, FL 32110

CBC1253392 (Exp: 08/31/2024) 386-931-2568

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 1009

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2014) (386) 931-2568 386-313-3445
RONALD E BANKS
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353741

PALM COAST, FL 32164

CAC049308 (Exp: 08/31/2010) (386) 437-4800 (386)445-0030
RYSZARD ALOJZY SKLADZIEN
Status Location Address State License Number Phone Fax
CANCEL

2 MARKET PLACE UNIT D

PALM COAST, FL 32137

CCC057546 (Exp: 08/31/2016) (386)445-7945 (386)446-3871
LARRY A JONES
Status Location Address State License Number Phone
INACTIVE

P. O. Box 1150

Bunnell, FL 32110

RF0055279 (Exp: 08/31/2025) (386) 437-0230
ANDREW TUOHY
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

4982 PALM COAST PKWY.

PALM COAST, FL 32137

STE. 7

PALM COAST, FL 32137

17814 (Exp: 06/24/2021) (386)446-5131 (386)446-2972
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
GAS FINAL 05/08/2009 FINAL APPROVED DROCKWELL
Note: per request from Dusty
FINAL COMPLETE BUILDING INSPECTION 05/08/2009 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION per request from Dusty
GAS ROUGH 05/07/2009 APPROVED DROCKWELL
Note: per contractor request
FINAL COMPLETE BUILDING INSPECTION 05/05/2009 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 5/5/2009 12:38:57 PM NEED GAS RISER DIAGRAM AND NEED TO VERIFY INSTALLATION.
FINAL COMPLETE BUILDING INSPECTION 05/04/2009 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 5/4/2009 12:52:40 PM INSTALL THERMOSTAT, INSTALL VENT IN SOFFIT, REMOVE ELECTRICAL TEMP., AIR HANDLER MOCP LABEL MISSING, CANNOT VERIFY THAT THE GAS LINE HAS A PERMIT AND WAS INSPECTED.
FINAL COMPLETE BUILDING INSPECTION 05/01/2009 Disapproved -FEE REQUIRED ACOOPER
Note: Inspection Resulted at 5/1/2009 10:27:53 AM INSTALL THERMOSTAT, INSTALL VENT IN SOFFIT, REMOVE ELECTRICAL TEMP., ATTIC STEPS NOT PROPERLY INSTALLED, ADD INSULATION OR SHEET, KITCHEN GFI INOP BY SINK, SMOKE DETECTORS INOPERABLE (UNABLE TO DETERMINE IF THEY ARE CO2 OR NOT), GARBAGE DISPOSAL INOPERABLE, PROPERLY MARK A/C FOR MOCP, PROOF OF FIREPROOFING FOR ATTIC STEPS, WELL PUMP WIRING INCOMPLETE, BEDROOM FANS INOPERABLE. ART 931 6966
STORMWATER FINAL INSPECTION 04/30/2009 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION DAMAGE TO CENTER OF ROAD.3' X 16' AREA FLUID SPILL $ 384.00 END OF DRIVEWAY 24' FEET = $ 292.OO...LIP END OF DRIVE IS 2'' + .....TOTAL DUE $676 ALLSO ON RIGHT SIDE OF HOUSE YOU MAY NEED TO REGADE FROM THE BACK REAR { INSIDE CORNER OF HOUSE TO THE FRONT CORNER OF HOUSE, THIS IS BECAUSE SURVEY'' DID NOT'' SHOW WATER FLOWING AWAY FROM HOUSE OR POOL . GARY LALIMA OF THE STORMWATER DEPARTMENT DID HAVE A PRE, FINAL GRADE SITE MEET WITH BUILDER . FINAL GRADE AND SOD BY BUILDER . 5/8/09 adjusted Road damage fee////per GL builder has fixed the end of the driveway///however the $100 base fee for repair was added to the petro spill amount/////and $192 removed for the 24 sq ft of driveway repair/////la
STORMWATER FINAL INSPECTION 04/29/2009 Disapproved -FEE REQUIRED GLALIMA
Note: 4/29/09 Sweep end of driveway clean. General clean-up. Sod is higher than pool pad. Re-grade required to direct stormwater to front swale. Suggest site meet to discuss necessary corrective actions.GL\\wk
RESIDENTIAL EARLY POWER 04/28/2009 APPROVED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 4/28/2009 3:24:13 PM DEL ELECTRIC
UTILITY COMPANY FINAL 04/27/2009 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 04/27/2009 CANCELLED BY INSPECTOR LAPTEKAR
Note: 9/29/08 No swale or road damage, per GL.\\wk 10/16/08 site check ok 4/24/09 cancelled inspection///final survey required with corrections
RESIDENTIAL EARLY POWER 04/27/2009 CANCELLED BY APPLICANT RMARVEL
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 04/17/2009 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 4/17/2009 12:56:47 PM ALL WIRING MUST BE SAFELY TERMINATED OR BLANKED OFF IN BOXES.
PRE DRIVEWAY 03/05/2009 APPROVED GLALIMA
PRE DRIVEWAY 03/04/2009 Disapproved -FEE REQUIRED GLALIMA
Note: 5'' ROAD AND OVER CULVERT PIPE , REMOVE TURN AROUND '' NOT ON SURVEY , OR YOU NEED A NEW SURVEY ,
INSULATION INSPECTION 01/20/2009 APPROVED CMINI
ALL ROUGH 01/15/2009 APPROVED ACOOPER
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 01/14/2009 CANCELLED BY INSPECTOR ACOOPER
Note: Inspection Resulted at 1/14/2009 2:49:59 PM LATH CALLED IN. LATH ALREADY CALLED IN AND PASSED. ROUGH TO BE CALLED IN WHEN TUBS ARE FILLED AND STACK IN FULL.
LATH /BRICK FLASHING 01/13/2009 APPROVED ACOOPER
ALL ROUGH 01/13/2009 Disapproved - NO FEE ACOOPER
Note: Inspection Resulted at 1/13/2009 1:04:48 PM NO WATER STACK, FRAME OUT THE DRYER VENT AND STOVE VENTS. ART 9316966
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/31/2008 APPROVED - AS NOTED ACOOPER
Note: REQUESTED BY CONTRACTOR Inspection Resulted at 12/31/2008 1:40:23 PM ADD ANCHOR BOLT AT SOLE PLATE BREAK WITHIN 12"
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/10/2008 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 12/10/2008 3:10:35 PM 1). MISSING NUTS ON GABLE END SOLE PLATE...ANCHOR BOLTS ON BEARING WALL SOLE PLATE NOT 32" O.C. WALL PLATE NUTS LOOSE....2).. FRAMING AT REAR MITERED WINDOW NOT TO DETAIL...3). VALLEY METAL FLASHING AND DRIP EDGE NEEDS TO BE INSTALLED FOR THIS INSPECTION...4). MISSING NAILS IN BUCKET AT HIP GIRDER AT MASTER..MISSING STRAP AT REAR ON TRUSS LETTER T....5). NEEDT O HAVE REVISION FOR ADDED WOOD HEADER WHICH REPAIRED TRUSSES BEAR ON..
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/26/2008 Disapproved -FEE REQUIRED RMARVEL
Note: called by contractor Inspection Resulted at 11/26/2008 3:42:26 PM NOT READY.
LINTEL 10/30/2008 APPROVED JHINDMAN
FOUNDATION SURVEY APPROVED BY STORMWATER 10/29/2008 APPROVED LAPTEKAR
FOUNDATION SURVEY APPROVED BY ZONING 10/29/2008 APPROVED BBARTON
TEMPORARY POLE 10/29/2008 APPROVED LHITES
RESIDENTIAL EARLY POWER 10/23/2008 Disapproved -FEE REQUIRED RMARVEL
Note: requested by James F. Inspection Resulted at 10/23/2008 3:33:15 PM CANNOT DO A EARLY POWER ON THIS HOUSE. IT IS NOT READY.
MONOLITHIC SLAB INSPECTION/SLAB 10/20/2008 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 10/17/2008 Disapproved -FEE REQUIRED RMARVEL
Note: requested by James Inspection Resulted at 10/17/2008 3:47:22 PM PLANS CALL FOR A 45 DEGREE CUT INTO FOOTERS FROM THE TOP THE BOTTOM ON INTERIOR BEARING WALLS. NOT A PARTIAL 45 AND 90.
FIRST ROUGH PLUMBING INSPECTION 10/15/2008 APPROVED JHINDMAN
Note: requested by contractor

Review History

Department Status Date In Date Out
BLD COMPLETE 05/06/2009 05/06/2009
Note: Released By: JJOSEPH revision gas line to fireplace
BLD COMPLETE 12/29/2008 12/29/2008
Note: Released By: JMCGOWEN Header detail above front entry
BLD HOLD 12/16/2008 12/16/2008
Note: Held By: FREODICA Revision: 1. For clarity on submitted revision on entry porch, provide detail/section showing how the revised roof trusses are supported by the Additional Beam and their connections and how the Beam is supported. The detail/section shall be signed and sealed by the Engineer.
BLD COMPLETE 12/05/2008 12/08/2008
Note: Released By: JJOSEPH Revision :Repair truss Q and R
BLD COMPLETE 09/26/2008 09/29/2008
Note: Released By: JMCGOWEN responding to comments reviewed by Fred R. checked by Joe M.
SW1 COMPLETE 09/22/2008 09/22/2008
Note: Released By: LAPTEKAR Received new site plan with adjusted FFE.
ZON COMPLETE 09/17/2008 09/17/2008
Note: Released By: ECOYNE
BLD HOLD 09/17/2008 09/18/2008
Note: Held By: FREODICA 1. Sheet 2 of 6: a. Plan shows gas fireplace to be vented at the the roof but is not shown in the elevation (sheet 1 of 6). b Provide fireplace detail and manufacturer's specifications and installation instructions. 2. Sheet 5 of 6: Frame Wall Opening Detail: a. Provide Simpson stud plate tie Model Number or its equivalent. b. Provide Glass Block installation detail. c. There are (2) types of lintel schedules shown, the precast concrete lintel schedule and power lintel schedule. There is a note " Lintel types may be interchanged as needed. Use comparable sizes". If (2) types would be used as noted, then revise the floor plan to indicate the comparable size for each window/door openings or if only (1) type would be used, then be specific. 3. Provide single line layout of HVAC sytem indicating location of supply diffuser, return grille, duct sizes and CFM.
SW1 HOLD 09/10/2008 09/10/2008
Note: Held By: LAPTEKAR 1. The proposed grades of the lot grading plan and the proposed FFEare not in synch, one or the other needs adjusting.
ZON HOLD 09/10/2008
Note: Held By: ECOYNE plantings in front of home and around front corner required tan color needs to be identified as to mfg, name or number

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤484.00 05/08/2009
EARLY POWER INSPECTION ¤40.00 05/08/2009
EARLY POWER INSPECTION ¤40.00 05/08/2009
EARLY POWER INSPECTION ¤40.00 05/08/2009
EARLY POWER INSPECTION ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REINSPECTION FEE ¤40.00 05/08/2009
REVISION ¤40.00 05/08/2009
REVISION ¤40.00 05/08/2009
REVISION ¤40.00 05/08/2009
ADDITIONAL FEE ¤40.00 05/08/2009
STORMWATER REINSPECTION FEE ¤35.00 05/08/2009
STORMWATER REINSPECTION FEE ¤35.00 05/08/2009
TRANS IMPACT FEE 6 - RESIDENTI ¤3,841.11 10/01/2008
BUILDING CODE ADMIN FUND ¤12.63 10/01/2008
ELECTRIC FEE ¤181.80 10/01/2008
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 10/01/2008
SITE PLAN 20 ¤20.00 10/01/2008
STORM WATER PERMIT FEES ¤80.00 10/01/2008
NEW RESIDENTIAL INSPECTIONS ¤406.00 10/01/2008
FIRE IMPACT FEE RES 4/01/08 ¤190.29 10/01/2008
MECHANICAL FEE ¤181.80 10/01/2008
PERMIT FEE ¤20.00 10/01/2008
PARKS IMPACT FEE 4/01/08 ¤1,229.60 10/01/2008
PLAN CHECK FEE ¤81.20 10/01/2008
PLUMBING FEE ¤181.80 10/01/2008
RADON FEE ¤12.63 10/01/2008
Fees Total Due: ¤0.00 Total Paid: ¤11,232.86