Permit #2008100275

Permit Details

Status: VOID

Parcel Id: 07-11-31-7031-RP11I-0020
Block: RP11I
Subdivision: -
Location Address: 1175 ROYAL PALM PKWY
Type: BC - BUILDING COMMERCIAL
NOC: NO DOCUMENTATION
Applicant name: NO CONTRACTOR OF RECORD
Owner: EMERIPALM LLC

Address

STE 500

SEATTLE, WA 98121

Address

3131 ELLIOT AVE

SEATTLE, WA 98121

Lot: 0020
Contracted Stated Job Value: ¤2,500,000.00
Job Description: NEW ASSISTED LIVING FACILITY "EMERITUS" - SP-MOD-07-08
Type: CN

Contractor

NO CONTRACTOR OF RECORD
Status State License Number
CANCEL CGC1111111 (Exp: 05/20/2016)

Sub Contractors

MATTHEW JOHN WITTWER
Status Location Address State License Number Phone Fax
ACTIVE

231 JEAN STREET

DAYTONA BEACH, FL 32114

EC0002058 (Exp: 08/31/2026) (386)255-1418 (386)255-3429
DAVID A CROSON
Status Location Address State License Number Phone Fax
ACTIVE

31550 COUNTY ROAD 437

SORRENTO, FL 32776

CMC1249402 (Exp: 08/31/2026) 407-380-6525 352-735-0623
WILLIAM EDWARD LAWSON
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 121126

CLERMONT, FL 34711

CFC041766 (Exp: 08/31/2026) 352-394-7171 (352)394-1201
SCOTT LANE SWINK
Status Location Address State License Number
CANCEL

8090 SUPPLY DR

FORT MYERS, FL 33912

CCC1328329 (Exp: 08/31/2012)

Inspection History

Type Request Date Result Inspector
FOUNDATION SURVEY APPROVED BY ZONING
FIRST ROUGH PLUMBING INSPECTION
SECOND ROUGH PLUMBING INSPECTION
PLUMBING FINAL
MONOLITHIC SLAB INSPECTION/SLAB
FOOTER
LINTEL
FRAMING
ROOF SHEATHING/BRACES/TIES/ DOWN CELL
ABOVE CEILING
H.V.A.C. ROUGH
H.V.A.C. FINAL
2ND ROUGH ELECTRICAL
TEMPORARY POLE
ELECTRIC FEEDER
COMMERCIAL POWER INSPECTION
ELECTRICAL FINAL
INSULATION INSPECTION
ROOF IN PROGRESS
FIREWALL INSPECTION
ENGINEERING FINAL
TRAFFIC ENGINEER
COMMERCIAL BUILDING FINAL
UTILITY COMMERCIAL FINAL
UTILITY COMPANY FINAL
LANDSCAPE FINAL
FIRE FINAL

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 11/03/2008 11/04/2008
Note: Released By: AWEBB
UD1 HOLD 10/30/2008 10/31/2008
Note: Held By: CJOHNSON 1. P501: a FS-1 at a 2 compartment sink in the kitchen area needs to be plumbed to the grease interceptor. All sinks and floor drains in the food preparation areas shall be plumber to interceptor. P302: Floor drains and sinks in the kitchen area shall be plumbed to the grease interceptor
FI1 HOLD 10/23/2008 10/30/2008
Note: Held By: JPATTEE Sheet LS1.1 indicate 2005 Florida Fire Prevention Code, this has not been adopted statewide by the State Fire Marshal. Unable to review
MECH COMPLETE 10/23/2008 10/23/2008
Note: Released By: FREODICA Held By: FREODICA
PLUM HOLD 10/22/2008 10/22/2008
Note: Held By: FREODICA 1. Provide kitchen plans/drawings listed on cover sheet for plumbing review coordination. 2. Indicate on plan the size of main sanitary line leaving the building. See sheet P501.
ELEC HOLD 10/20/2008 10/21/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008100275 (Emeritus Senior Living @ 1175 Royal Palm Pkwy.) 10/21/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E501 shows Panel GDP feeding Panel KE. Panel GDP schedule on E602 does not reflect circuit breaker for Panel KE. Provide circuit breaker. 2. E601 & E602: Provide load calculations for all panels, Generator feeder and Secondary Service feeder. When transferring load of a sub-panel into the panel it is fed from, please do not spread load evenly across all 3 phases unless a transformer is involved. 3. E602: Please verify load for Irrigation pump circuit H-20. Load in panel appears as only 1A. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD HOLD 10/17/2008 10/22/2008
Note: Held By: JJOSEPH 1.Provide the following missing sheet: AS1.1, AS1.2, AS1.3, LS1.2, LS1.3, A0.1, A1.3, A1.4, A2.3, A5.1, A6.2 and kitchen pages. 2. Provide Florida Product Approval Number for all Doors and Windows. 3. Provide a lintel schedule. 4.Revise the page LS1.1 to precise Exterior wall/Unprotected or protected opening allowed (table 704.8 of FBC 2004). 5. The detail shown on page A1.1 making reference to section 2 on page A6.2 cannot be found for missing page.
ZON COMPLETE 10/15/2008 10/16/2008
Note: Released By: ECOYNE Held By: ECOYNE DO height of bldg 34' Actual height is 37.8' 35,048 sq ft total on DO plans state 36,198 sq ft
ELEC CANCEL
BLD CANCEL
PLUM CANCEL
FI1 HOLD 11/05/2008
Note: Held By: JPATTEE 1) Sheet A6.2 is missing. 2) Sheet M202 indicates a 10x10 return air duct pentrating a smoke barrier serving a corridor with no damper. Clarify 3) Sheets E301, E302 show addendum #1, 9/15/08 provide clarification as to what this note means. Are these items being added or deleted? 4) Fire alarm system, automatic fire sprinkler system, hood and fire suppression for kitchen equipment and underground fire lines shall require separate permitting and plans for each system. More comments may be generated upon further review
UD1 CANCEL
FI1 CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN COMMERCIAL ¤60.00
ELECTRIC FEE ¤1,560.00
FIRE PLANS REVIEW ¤25.00
MECHANICAL FEE ¤1,560.00
PERMIT FEE ¤13,750.00
PLAN CHECK FEE ¤2,875.00
PLUMBING FEE ¤1,560.00
SITE PLAN 20 ¤20.00
Fees Total Due: ¤21,410.00 Total Paid: ¤0.00