Permit #2008110040
Permit Details
Status: COED
| Parcel Id: 13-11-30-3020-00000-0022 |
| Total Square Footage: 944 sqft |
| Block: 00000 |
| Subdivision: 2151 - Home Depot Center Plaza |
| Job Phone: (386)931-4741 |
| Location Address: 55 PLAZA DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 11/18/2008 |
| NOC: RECORDED |
| Applicant name: FOSTER H COLEMAN |
| Owner: PALM COAST INVESTMENT PROPERTIES |
|
Address 1 FLORIDA PARK DRIVE PALM COAST, FL 32137 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤9,875.00 |
| Job Description: UNIT D-4 - BEAUTY SHOP RENOVATIONS/ TANGLES SALON |
| Type: CN |
Contractor
Fantastic Homes Const.Inc. (Foster Coleman)
| Status | Location Address | State License Number | Phone |
| CANCEL |
132 N PENINSULA DR DAYTONA BEACH, FL 32118 |
CGC003579 (Exp: 08/31/2016) | 386-307-1666 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 12/18/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL BUILDING FINAL | 12/18/2008 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 12/16/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 12/11/2008 | CANCELLED BY APPLICANT | RMARVEL |
| COMMERCIAL BUILDING FINAL | 12/11/2008 | CANCELLED BY APPLICANT | RMARVEL |
| FIRE FINAL | 12/11/2008 | APPROVED | JPATTEE |
| H.V.A.C. FINAL | 12/10/2008 | APPROVED | JMCGOWEN |
| ABOVE CEILING | 12/05/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL POWER INSPECTION | 12/05/2008 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 12/5/2008 3:17:37 PM COLE | |||
| ABOVE CEILING | 12/03/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/3/2008 3:58:38 PM NOT READY. NEED TO FINISH SUPPORTS AND INSTALL BOXES FOR THE FANS. | |||
| PLUMBING FINAL | 12/03/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 12/3/2008 3:38:45 PM NOT READY, FIXTURES ARE NOT SET | |||
| COMMERCIAL POWER INSPECTION | 12/02/2008 | CANCELLED BY APPLICANT | AIRS WEB |
| UTILITY COMMERCIAL FINAL | 12/01/2008 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 12/01/2008 | APPROVED | KKING |
| FIREWALL FINAL INSPECTION | 11/24/2008 | APPROVED | JPATTEE |
| SECOND ROUGH PLUMBING INSPECTION | 11/21/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION requested by foster | |||
| SECOND ROUGH PLUMBING INSPECTION | 11/20/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 11/20/2008 3:20:48 PM REVISION FOR OVER NOTCHED STUDS NEED TO BE APPROVED BY PLAN REVIEW. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 11/20/2008 | APPROVED | CMINI |
| FRAMING | 11/20/2008 | APPROVED | CMINI |
| 2ND ROUGH ELECTRICAL | 11/20/2008 | APPROVED | JMCGOWEN |
| ABOVE CEILING | 11/20/2008 | CANCELLED BY APPLICANT | JMCGOWEN |
| H.V.A.C. ROUGH | 11/19/2008 | APPROVED | JMCGOWEN |
| 2ND ROUGH ELECTRICAL | 11/19/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 11/19/2008 2:20:53 PM NEED REVISIONS SHOWING ADDED RECEPTACLES, RELOCATION OF DEVICES, CHANGING OF DUPLEX TO QUADS AND QUADS TO DUPLEXES. INSTALL NAIL PLATES WHERE REQUIRED. | |||
| ABOVE CEILING | 11/19/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 11/19/2008 2:20:53 PM NOT READY. | |||
| FRAMING | 11/19/2008 | APPROVED | CMINI |
| SECOND ROUGH PLUMBING INSPECTION | 11/19/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 11/19/2008 3:49:31 PM STUD WALL HAS BEEN NOTCHED OVER 40 %. OK TO COVER UP UNDERGROUND. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/19/2008 | 11/20/2008 |
| Note: Released By: JJOSEPH revison - Add a wall furred (2x4) for plumbing | |||
| ELEC | COMPLETE | 11/19/2008 | 11/20/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision: Relocated receptacles, added 3W switch. No load increase. | |||
| FI1 | COMPLETE | 11/18/2008 | 11/18/2008 |
| Note: Released By: JPATTEE | |||
| ELEC | COMPLETE | 11/13/2008 | 11/13/2008 |
| Note: Released By: SKNOPF Approved for Release. | |||
| MECH | COMPLETE | 11/13/2008 | 11/13/2008 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 11/13/2008 | 11/13/2008 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 11/13/2008 | 11/13/2008 |
| Note: Released By: JJOSEPH | |||
| UD1 | COMPLETE | 11/13/2008 | 11/17/2008 |
| Note: Released By: CJOHNSON | |||
| MECH | HOLD | 11/07/2008 | 11/07/2008 |
| Note: Held By: FREODICA 1. Provide AHU/CU and Exhaust fan schedules. 2. Provide support detail fo AHU. 3. Indicate location and size of access opening for AHU per FMC 2004 Sec. 306.3. 4. Provide calculation for the required outdoor ventilation air per FMC 2004 Table 403.3. | |||
| PLUM | HOLD | 11/07/2008 | 11/07/2008 |
| Note: Held By: FREODICA 1. Provide plumbing fixture/equipment schedule. Clarify if toilet fixtures are new or existing. If existing, delete Handicapped Plumbing Fixture Notes. 2. Provide domestic water plan and riser diagram. 3. Indicate how the water heater relief discharge would be discharged. | |||
| ELEC | HOLD | 11/07/2008 | 11/07/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008110040 (Beauty Shop @ Unit D-4 55 Plaza Dr.) 11/7/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Revise Tenant Load Calculation to include all 39 receptacles shown on Electric Floor Plan. 2. Identify circuit for 220V stacked washer and dryer in panel. Include this appliance load in revised Load Calculation. 3. Locate sign circuit #10 on Electric Floor Plan. Include sign load in revised Load Calculation per NEC 220.14(F). 4. Provide Electric Riser Diagram showing Meter, Panel and Panel feeder conductor size. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | HOLD | 11/06/2008 | 11/10/2008 |
| Note: Held By: JJOSEPH Provide informartion details as for the existing window that is not shown in the office room of your plan.(Unit D-4) | |||
| ZON | COMPLETE | 11/05/2008 | 11/05/2008 |
| Note: Released By: BBARTON 944 sqft beauty salon (verified use) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/08/2008 |
| REINSPECTION FEE | ¤40.00 | 12/08/2008 |
| REVISION | ¤40.00 | 12/02/2008 |
| REVISION | ¤40.00 | 12/02/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| ADMIN COMMERCIAL | ¤60.00 | 11/18/2008 |
| ELECTRIC FEE | ¤65.92 | 11/18/2008 |
| FIRE PLANS REVIEW | ¤25.00 | 11/18/2008 |
| MECHANICAL FEE | ¤65.92 | 11/18/2008 |
| PERMIT FEE | ¤69.13 | 11/18/2008 |
| PLAN CHECK FEE | ¤100.00 | 11/18/2008 |
| PLUMBING FEE | ¤65.92 | 11/18/2008 |
| SITE PLAN 20 | ¤20.00 | 11/18/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤791.89 |