Permit #2008110040

Permit Details

Status: COED

Parcel Id: 13-11-30-3020-00000-0022
Total Square Footage: 944 sqft
Block: 00000
Subdivision: 2151 - Home Depot Center Plaza
Job Phone: (386)931-4741
Location Address: 55 PLAZA DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 11/18/2008
NOC: RECORDED
Applicant name: FOSTER H COLEMAN
Owner: PALM COAST INVESTMENT PROPERTIES

Address

1 FLORIDA PARK DRIVE

PALM COAST, FL 32137

Lot: 0060
Contracted Stated Job Value: ¤9,875.00
Job Description: UNIT D-4 - BEAUTY SHOP RENOVATIONS/ TANGLES SALON
Type: CN

Contractor

Fantastic Homes Const.Inc. (Foster Coleman)
Status Location Address State License Number Phone
CANCEL

132 N PENINSULA DR

DAYTONA BEACH, FL 32118

CGC003579 (Exp: 08/31/2016) 386-307-1666

Sub Contractors

GLEN STEWART COLE
Status Location Address State License Number Phone Fax
HOLD

P. O. Box 1677

Palm Coast, FL 32136

EC0002522 (Exp: 08/31/2010) (386) 437-4364 (386)437-0412
MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 12/18/2008 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
COMMERCIAL BUILDING FINAL 12/18/2008 FINAL APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ELECTRICAL FINAL 12/16/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ELECTRICAL FINAL 12/11/2008 CANCELLED BY APPLICANT RMARVEL
COMMERCIAL BUILDING FINAL 12/11/2008 CANCELLED BY APPLICANT RMARVEL
FIRE FINAL 12/11/2008 APPROVED JPATTEE
H.V.A.C. FINAL 12/10/2008 APPROVED JMCGOWEN
ABOVE CEILING 12/05/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
COMMERCIAL POWER INSPECTION 12/05/2008 APPROVED RMARVEL
Note: Inspection Resulted at 12/5/2008 3:17:37 PM COLE
ABOVE CEILING 12/03/2008 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 12/3/2008 3:58:38 PM NOT READY. NEED TO FINISH SUPPORTS AND INSTALL BOXES FOR THE FANS.
PLUMBING FINAL 12/03/2008 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 12/3/2008 3:38:45 PM NOT READY, FIXTURES ARE NOT SET
COMMERCIAL POWER INSPECTION 12/02/2008 CANCELLED BY APPLICANT AIRS WEB
UTILITY COMMERCIAL FINAL 12/01/2008 APPROVED KKING
UTILITY COMPANY FINAL 12/01/2008 APPROVED KKING
FIREWALL FINAL INSPECTION 11/24/2008 APPROVED JPATTEE
SECOND ROUGH PLUMBING INSPECTION 11/21/2008 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION requested by foster
SECOND ROUGH PLUMBING INSPECTION 11/20/2008 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 11/20/2008 3:20:48 PM REVISION FOR OVER NOTCHED STUDS NEED TO BE APPROVED BY PLAN REVIEW.
MONOLITHIC SLAB INSPECTION/SLAB 11/20/2008 APPROVED CMINI
FRAMING 11/20/2008 APPROVED CMINI
2ND ROUGH ELECTRICAL 11/20/2008 APPROVED JMCGOWEN
ABOVE CEILING 11/20/2008 CANCELLED BY APPLICANT JMCGOWEN
H.V.A.C. ROUGH 11/19/2008 APPROVED JMCGOWEN
2ND ROUGH ELECTRICAL 11/19/2008 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 11/19/2008 2:20:53 PM NEED REVISIONS SHOWING ADDED RECEPTACLES, RELOCATION OF DEVICES, CHANGING OF DUPLEX TO QUADS AND QUADS TO DUPLEXES. INSTALL NAIL PLATES WHERE REQUIRED.
ABOVE CEILING 11/19/2008 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 11/19/2008 2:20:53 PM NOT READY.
FRAMING 11/19/2008 APPROVED CMINI
SECOND ROUGH PLUMBING INSPECTION 11/19/2008 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 11/19/2008 3:49:31 PM STUD WALL HAS BEEN NOTCHED OVER 40 %. OK TO COVER UP UNDERGROUND.

Review History

Department Status Date In Date Out
BLD COMPLETE 11/19/2008 11/20/2008
Note: Released By: JJOSEPH revison - Add a wall furred (2x4) for plumbing
ELEC COMPLETE 11/19/2008 11/20/2008
Note: Released By: SKNOPF Approved for Release. Revision: Relocated receptacles, added 3W switch. No load increase.
FI1 COMPLETE 11/18/2008 11/18/2008
Note: Released By: JPATTEE
ELEC COMPLETE 11/13/2008 11/13/2008
Note: Released By: SKNOPF Approved for Release.
MECH COMPLETE 11/13/2008 11/13/2008
Note: Released By: FREODICA
PLUM COMPLETE 11/13/2008 11/13/2008
Note: Released By: FREODICA
BLD COMPLETE 11/13/2008 11/13/2008
Note: Released By: JJOSEPH
UD1 COMPLETE 11/13/2008 11/17/2008
Note: Released By: CJOHNSON
MECH HOLD 11/07/2008 11/07/2008
Note: Held By: FREODICA 1. Provide AHU/CU and Exhaust fan schedules. 2. Provide support detail fo AHU. 3. Indicate location and size of access opening for AHU per FMC 2004 Sec. 306.3. 4. Provide calculation for the required outdoor ventilation air per FMC 2004 Table 403.3.
PLUM HOLD 11/07/2008 11/07/2008
Note: Held By: FREODICA 1. Provide plumbing fixture/equipment schedule. Clarify if toilet fixtures are new or existing. If existing, delete Handicapped Plumbing Fixture Notes. 2. Provide domestic water plan and riser diagram. 3. Indicate how the water heater relief discharge would be discharged.
ELEC HOLD 11/07/2008 11/07/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2008110040 (Beauty Shop @ Unit D-4 55 Plaza Dr.) 11/7/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Revise Tenant Load Calculation to include all 39 receptacles shown on Electric Floor Plan. 2. Identify circuit for 220V stacked washer and dryer in panel. Include this appliance load in revised Load Calculation. 3. Locate sign circuit #10 on Electric Floor Plan. Include sign load in revised Load Calculation per NEC 220.14(F). 4. Provide Electric Riser Diagram showing Meter, Panel and Panel feeder conductor size. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD HOLD 11/06/2008 11/10/2008
Note: Held By: JJOSEPH Provide informartion details as for the existing window that is not shown in the office room of your plan.(Unit D-4)
ZON COMPLETE 11/05/2008 11/05/2008
Note: Released By: BBARTON 944 sqft beauty salon (verified use)

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/08/2008
REINSPECTION FEE ¤40.00 12/08/2008
REVISION ¤40.00 12/02/2008
REVISION ¤40.00 12/02/2008
REINSPECTION FEE ¤40.00 12/02/2008
REINSPECTION FEE ¤40.00 12/02/2008
REINSPECTION FEE ¤40.00 12/02/2008
REINSPECTION FEE ¤40.00 12/02/2008
ADMIN COMMERCIAL ¤60.00 11/18/2008
ELECTRIC FEE ¤65.92 11/18/2008
FIRE PLANS REVIEW ¤25.00 11/18/2008
MECHANICAL FEE ¤65.92 11/18/2008
PERMIT FEE ¤69.13 11/18/2008
PLAN CHECK FEE ¤100.00 11/18/2008
PLUMBING FEE ¤65.92 11/18/2008
SITE PLAN 20 ¤20.00 11/18/2008
Fees Total Due: ¤0.00 Total Paid: ¤791.89