I want to search for...
Permit #2008110072
Permit Details
Status: COED
| Parcel Id: 13-11-30-3020-00000-0022 |
| Total Square Footage: 944 sqft |
| Block: 00000 |
| Subdivision: 2151 - Home Depot Center Plaza |
| Job Phone: (386)931-4741 |
| Location Address: 55 PLAZA DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 11/18/2008 |
| NOC: RECORDED |
| Applicant name: FOSTER H COLEMAN |
| Owner: PALM COAST INVESTMENT PROPERTIES |
|
Address 1 FLORIDA PARK DRIVE PALM COAST, FL 32137 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤9,765.00 |
| Job Description: UNIT D-7 WALL, ELECT. OUTLETS & LIGHTS- DRYWALL HEARING AID STORE |
| Type: CN |
Contractor
Fantastic Homes Const.Inc. (Foster Coleman)
| Status | Location Address | State License Number | Phone |
| CANCEL |
132 N PENINSULA DR DAYTONA BEACH, FL 32118 |
CGC003579 (Exp: 08/31/2016) | 386-307-1666 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRICAL FINAL | 12/15/2008 | FINAL APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL BUILDING FINAL | 12/05/2008 | APPROVED | RMARVEL |
| ELECTRICAL FINAL | 12/05/2008 | Disapproved - NO FEE | RMARVEL |
| Note: Inspection Resulted at 12/5/2008 3:17:36 PM REVISE PANEL SCHEDULE TO MATCH PLANS. | |||
| H.V.A.C. FINAL | 12/05/2008 | APPROVED | JMCGOWEN |
| FIRE FINAL | 12/05/2008 | APPROVED | JPATTEE |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 12/03/2008 | CANCELLED BY APPLICANT | JPATTEE |
| PLUMBING FINAL | 12/03/2008 | APPROVED | JHINDMAN |
| COMMERCIAL POWER INSPECTION | 12/02/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/2/2008 3:41:07 PM COLE | |||
| COMMERCIAL POWER INSPECTION | 12/01/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: REQUESTED BY FOSTER Inspection Resulted at 12/1/2008 3:27:34 PM NEED TO TORQUE LUGS ON FEEDERS. ALSO TO CHECK AT FINAL MC AT SCUTTLE NEEDS TO BE PROTECTED WITHIN 6FT OF SCUTTLE HOLE. | |||
| UTILITY COMMERCIAL FINAL | 12/01/2008 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 12/01/2008 | APPROVED | KKING |
| FIREWALL INSPECTION | 11/24/2008 | APPROVED | JPATTEE |
| 2ND ROUGH ELECTRICAL | 11/21/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION requested by Foster | |||
| INSULATION INSPECTION | 11/20/2008 | APPROVED | CMINI |
| 2ND ROUGH ELECTRICAL | 11/20/2008 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: Inspection Resulted at 11/20/2008 3:16:44 PM STILL NEED PUT WATER COOLER ON SEPERATE CIRCUIT 13 LOOK AT PLANS. UNUSED CONNECTORS ARE NOT KO PLUGS. | |||
| SECOND ROUGH PLUMBING INSPECTION | 11/19/2008 | APPROVED - AS NOTED | JHINDMAN |
| Note: Inspection Resulted at 11/19/2008 3:49:30 PM INSTALLED AT TIME OF SHELL | |||
| 2ND ROUGH ELECTRICAL | 11/19/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 11/19/2008 2:20:54 PM WATER COOLER IS CALLING FOR ITS OWN CIRCUIT. MOVE SWITCH AT FRONT DOOR AS SHOWN ON THE PLANS. | |||
| FRAMING | 11/19/2008 | APPROVED | CMINI |
| ABOVE CEILING | 11/19/2008 | APPROVED - AS NOTED | RMARVEL |
| Note: Inspection Resulted at 11/19/2008 2:20:54 PM REMOVE STRAPS FROM GUSSETT PLATES. STRAP MC IN LOCATION SHOWN TO SUPER. | |||
| H.V.A.C. ROUGH | 11/19/2008 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 12/11/2008 | 12/11/2008 |
| Note: Released By: SKNOPF Revision Response to comments | |||
| ELEC | HOLD | 12/08/2008 | 12/09/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008110072 (Hearing Aid Store @ Unit D-7 55 Plaza Dr.) 12/9/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. NEC 600.5 specifically states the required sign circuit supply no other load. Sign circuit #10 is now shown tied into room lighting. Revise. Note circuit #6 is still identified in panel as "sign". 2. Water Heater EEMAX Mod SP2412 on website appears to have a 2.4KW, 20A, 120V load and is shown requiring #10AWG wire. Revise load calculation and circuit breaker size in panel (per NEC 240.4 and 422.11(E)). Identify wire size requirements on plans for this circuit. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 160 Cypress Point Pkwy, Suite B-106 Palm Coast, Florida 32164 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | COMPLETE | 11/18/2008 | 11/18/2008 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 11/17/2008 | 11/17/2008 |
| Note: Released By: FREODICA Correction responce to comments | |||
| PLUM | COMPLETE | 11/17/2008 | 11/17/2008 |
| Note: Released By: FREODICA | |||
| UD1 | COMPLETE | 11/13/2008 | 11/14/2008 |
| Note: Released By: CJOHNSON | |||
| BLD | HOLD | 11/10/2008 | 11/10/2008 |
| Note: Held By: JJOSEPH Provide informartion details as for the existing window that is not shown in the office room of your plan.(Unit D-7) | |||
| ELEC | COMPLETE | 11/10/2008 | 11/10/2008 |
| Note: Released By: SKNOPF Approved for Release. | |||
| FI1 | COMPLETE | 11/10/2008 | 11/13/2008 |
| Note: Released By: JPATTEE | |||
| MECH | HOLD | 11/10/2008 | 11/10/2008 |
| Note: Held By: FREODICA 1. Provide Air Handling Unit (AHU-7)/Condender Unit (CU) and Exhaust Fan Schedules. 2. Indicate on plan the distributed supply air in CFM. 3. Transfer grille between toilet and corridor which is used as a retun plenum is not allowed by code. 4. Revise name designation of AHU No.7 on ground floor to CU-7. | |||
| PLUM | HOLD | 11/10/2008 | 11/10/2008 |
| Note: Held By: FREODICA 1. Provide location of water heater. Energy calculations show 30 gal. capacity. Do you need this much to supply only (1) lavatory? Please clarify. | |||
| ZON | COMPLETE | 11/07/2008 | 11/10/2008 |
| Note: Released By: BBARTON verified use interior work only |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤80.00 | 12/12/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| REINSPECTION FEE | ¤40.00 | 12/02/2008 |
| SITE PLAN 20 | ¤20.00 | 11/18/2008 |
| ADMIN COMMERCIAL | ¤60.00 | 11/18/2008 |
| ELECTRIC FEE | ¤65.92 | 11/18/2008 |
| FIRE PLANS REVIEW | ¤25.00 | 11/18/2008 |
| MECHANICAL FEE | ¤65.92 | 11/18/2008 |
| PERMIT FEE | ¤69.13 | 11/18/2008 |
| PLAN CHECK FEE | ¤100.00 | 11/18/2008 |
| PLUMBING FEE | ¤65.92 | 11/18/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤671.89 |