I want to search for...
Permit #2008120371
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00210-0200 |
| CONDITIONED SPACE: 3001 sqft |
| GARAGE: 480 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 3541 sqft |
| Block: 00210 |
| Subdivision: 2215 - SECTION 58-SEMINOLE PARK |
| Job Phone: (386) 445-1342 |
| Location Address: 10 SEVILLE ORANGE PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/30/2008 |
| NOC: RECORDED |
| Applicant name: GIULIO LANCIA |
| Owner: HEALY, BRIAN K |
|
Address 8 SEVILLE ORANGE PATH PALM COAST, FL 32164 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤325,000.00 |
| Job Description: NEW CONSTRUCTION |
| Type: CN |
Contractor
LANCIA CUSTOM HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 351602 FLAGLER BEACH , FL 32136 |
CBC047064 (Exp: 08/31/2018) | (386) 445-1342 | (386)445-7509 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
SINCLAIR W STICKLE
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
15 HARGROVE GRADE BLD 2 UNIT G PALM COAST, FL 32137 |
CAC052428 (Exp: 08/31/2018) | 386-446-1114 | (386)446-1278 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
JOANNA S REELEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2 MARKET PLACE D PALM COAST, FL 32137 |
CCC1327485 (Exp: 08/31/2020) | 386-445-7945 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/20/2009 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LANDSCAPE FINAL | 07/17/2009 | FINAL APPROVED | WBUTLER |
| Note: per Bill Butler approval | |||
| FINAL COMPLETE BUILDING INSPECTION | 07/17/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 7/17/2009 2:07:20 PM REATTACH HOUSE NUMBER. ANCHOR CONDENSER UNIT TO SLAB. AIR HANDLER CLOSET DOOR IS DAMAGING DUCT. NEED HARDWARE ON DOORS. SEAL DRYWALL HOLES IN CEILINGS WHERE WIRES PENETRATE. NEED COVERS ON OPEN WALL PLATES. | |||
| STORMWATER FINAL INSPECTION | 07/14/2009 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 07/14/2009 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 07/10/2009 | Disapproved - NO FEE | GLALIMA |
| Note: Site check okay on 1/21/09, per GL.\\wk 7/10/09 REMOVE ALL TRASH AT '' REAR '' AND AT LEFT AND RIGHT OF PROPERTY LINE . WOOD/ CUPS / SILT FENCE / AND ALL OTHER TRASH. FILL IN HOLES , AND RAKE OFF DAMAGE TO MEDIAN //GL | |||
| RESIDENTIAL EARLY POWER | 06/11/2009 | APPROVED | JHINDMAN |
| Note: Inspection Resulted at 6/11/2009 1:28:06 PM CALLED FPL 1:30 | |||
| PRE DRIVEWAY | 06/10/2009 | APPROVED | GLALIMA |
| INSULATION INSPECTION | 04/24/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 04/23/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 4/23/2009 12:26:20 PM DRAFT STOP TUB BOX 2ND FLOOR/PANEL BOX-SEE GREEN/ARCH WAY AT FRONT DOOR/ARCH WAY IN LIVING ROOM-SEE GREEN SPRAY | |||
| ALL ROUGH | 04/08/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 03/19/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 3/19/2009 2:46:19 PM ELECTRIC NOT TO PLAN-NEED REVISION OR APPROVED AS-BUILT/MOVE NM CABLES AWAY FROM RECESSED FIXTURES/LOCATION OF A/C AIR-HANDLER NOT PER PLAN.SERVICE PANELS NOT GROUNDED/BONDED/FILL AC CHASE WITH APPRPORIATE MATERIAL | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/13/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/06/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 3/6/2009 1:01:38 PM TAP-CON ALL 2X SUPPORTING ROOF SHEATHING/ALL ROOF METALS INSTALLED BY THIS INSPECTION/NAIL C2A STRAP TO TRUSS/PROVIDE STAIR DETAIL/PROVIDE LEDGER DETAILS/PROVIDE FIREPLACE FRAMING/TIE-DOWN DETAIL.CHECK ALL THREADED RODS(TIGHTEN) | |||
| LINTEL | 02/13/2009 | APPROVED | JHINDMAN |
| Note: Inspection Resulted at 2/13/2009 10:56:25 AM 2ND LIFT | |||
| LINTEL | 02/03/2009 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 2/3/2009 3:08:51 PM 1ST LIFT OK TO POUR CELLS.NEED TO CALL LINTEL AGAIN WHEN 2ND LIFT IS COMPLETE. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 01/28/2009 | APPROVED | WKINELL |
| FOUNDATION SURVEY APPROVED BY ZONING | 01/28/2009 | APPROVED | ECOYNE |
| R.O.W. DAMAGE INSPECTION | 01/23/2009 | APPROVED - AS NOTED | GLALIMA |
| Note: Check damage ...water meter recently installed. 1/23/09 per GL, 6 sq ft road damage.\\wk | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 01/23/2009 | APPROVED | CMINI |
| Note: requested by CONTRACTOR | |||
| FIRST ROUGH PLUMBING INSPECTION | 01/20/2009 | APPROVED | DROCKWELL |
| TEMPORARY POLE | 01/12/2009 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 07/13/2009 | 07/14/2009 |
| Note: Released By: ECOYNE revised trees location and additing more trees | |||
| ELEC | COMPLETE | 04/07/2009 | 04/07/2009 |
| Note: Released By: JMCGOWEN | |||
| ELEC | HOLD | 04/07/2009 | 04/07/2009 |
| Note: Held By: JMCGOWEN provide updated service conductor sizes that will meet demand load as per NEC T310.15 | |||
| MECH | COMPLETE | 04/06/2009 | 04/07/2009 |
| Note: Released By: JMCGOWEN RESUBMIT PER FREDS COMMENTS | |||
| ELEC | HOLD | 04/02/2009 | 04/02/2009 |
| Note: Held By: SKNOPF | |||
| MECH | HOLD | 04/02/2009 | 04/06/2009 |
| Note: Held By: FREODICA Revision: 1. Provide a minimum size of 11x17 plan size single line diagram of HVAC duct layout including CFM and duct sizes signed by FL licensed HVAC mechanical contractor. 2. Revise the energy calculations to reflect the changes on quantity of HVAC unit used ( 2 units to 1 unit). | |||
| ELEC | HOLD | 04/02/2009 | 04/02/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2008120371 (Residence @ 8 Seville Orange Path) 4/2/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Must have 2 copies of full size revision plans for scanning to public record. 2. Revise electrical 400A riser to reflect a separate set of 4/0 aluminum conductors from the meter to each of the 200A panels to meet demand loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 03/12/2009 | 03/12/2009 |
| Note: Released By: FREODICA 1. Revision: Submitted stair details. (Dwg. A-3.2.1 dated 3-12-09) | |||
| ZON | COMPLETE | 12/29/2008 | 12/29/2008 |
| Note: Released By: ECOYNE | |||
| SW1 | COMPLETE | 12/29/2008 | 12/29/2008 |
| Note: Released By: WKINELL | |||
| BLD | COMPLETE | 12/23/2008 | 12/30/2008 |
| Note: Released By: JMCGOWEN reviewed by Auba and checked by Joe M. | |||
| BLD | HOLD | 12/19/2008 | 12/22/2008 |
| Note: Held By: JJOSEPH 1.Provide impact resistant windows and doors or indicate on plan what opening protection will be used to meet FBC 2004 section 1609.1.4. 2.Provide single line layout of HVAC system indicating duct sizes , location of supply air diffusers and return grille including CFM. 3. Provide stairs details and indicate tyhe stair traeds and risers size. 4.Provide fastening or nailing schedule. 5. Provide lintel schedule. 6. provide roof sheating details. | |||
| ZON | COMPLETE | 12/18/2008 | 12/19/2008 |
| Note: Released By: ECOYNE correction | |||
| ZON | HOLD | 12/17/2008 | 12/17/2008 |
| Note: Held By: ECOYNE 22 sq ft rear porch shows on plans but does not on survey. revision came in showing 5.33' X 5' concret slab still does not show 22 sq ft rear porch. spoke to contractor will make corrections 12/19/08 | |||
| PLLA | HOLD | 12/17/2008 | 12/18/2008 |
| Note: Held By: ECOYNE 3 more trees required on lot landscaping need to wrap around left corner need tree caliper on new trees need sod type mechanical equip not landscaped. | |||
| PLLA | COMPLETE | 12/19/2008 | |
| Note: Released By: ECOYNE 12 trees satisfied irrigation system will be installed |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 07/20/2009 |
| REINSPECTION FEE | ¤40.00 | 07/20/2009 |
| REINSPECTION FEE | ¤40.00 | 07/20/2009 |
| REINSPECTION FEE | ¤40.00 | 07/20/2009 |
| REINSPECTION FEE | ¤40.00 | 07/20/2009 |
| REVISION | ¤40.00 | 07/20/2009 |
| REVISION | ¤40.00 | 07/20/2009 |
| REVISION | ¤40.00 | 07/20/2009 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/30/2008 |
| SITE PLAN 20 | ¤20.00 | 12/30/2008 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/30/2008 |
| TRANS IMPACT FEE 6 - RESIDENTI | ¤3,841.11 | 12/30/2008 |
| NEW RESIDENTIAL INSPECTIONS | ¤650.00 | 12/30/2008 |
| FIRE IMPACT FEE RES 4/01/08 | ¤190.29 | 12/30/2008 |
| MECHANICAL FEE | ¤255.00 | 12/30/2008 |
| PERMIT FEE | ¤20.00 | 12/30/2008 |
| PARKS IMPACT FEE 4/01/08 | ¤1,229.60 | 12/30/2008 |
| PLAN CHECK FEE | ¤130.00 | 12/30/2008 |
| PLUMBING FEE | ¤255.00 | 12/30/2008 |
| RADON FEE | ¤17.71 | 12/30/2008 |
| BUILDING CODE ADMIN FUND | ¤17.71 | 12/30/2008 |
| ELECTRIC FEE | ¤255.00 | 12/30/2008 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,881.42 |