Permit #2009020016
Permit Details
Status: COED
| Parcel Id: 09-12-31-0000-02030-0020 |
| COMMERCIAL SQUARE FOOTAGE: 3000 sqft |
| Total Square Footage: 3000 sqft |
| Block: 02030 |
| Subdivision: - |
| Job Phone: 407-916-7235 |
| Location Address: 60 MEMORIAL MEDICAL PKWY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 03/10/2009 |
| NOC: RECORDED |
| Applicant name: ROCKY MCMICHEN |
| Owner: MEMORIAL HOSPITAL-FLAGLER INC |
|
Address 875 STERTHAUS AVENUE ORMOND BEACH, FL 32174 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤500,000.00 |
| Job Description: EMERGENCY ROOM & LAB RENOVATION |
| Type: CN |
Contractor
THE ROBINS & MORTON GROUP
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
1900 SUMMIT TOWER BLVD. ORLANDO, FL 32810 |
SUITE 150 ORLANDO, FL 32810 |
CGC1506087 (Exp: 08/31/2012) | 407-916-7235 | 407-916-7632 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
TODD SHERWOOD MORGAN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
777 BENNETT DRIVE LONGWOOD, FL 32750 |
CFC043045 (Exp: 08/31/2022) | (407)682-1313 | (407)682-5166 |
TODD SHERWOOD MORGAN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
777 BENNETT DRIVE LONGWOOD , FL 32750 |
CMC039581 (Exp: 08/31/2022) | 407-682-1313 | (407)682-5166 |
Inspection History
| Type | Request Date | Result | Inspector |
| COMMERCIAL POWER INSPECTION | 06/25/2009 | APPROVED | RMARVEL |
| COMMERCIAL BUILDING FINAL | 06/25/2009 | FINAL APPROVED | RMARVEL |
| ELECTRICAL FINAL | 06/22/2009 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/22/2009 11:58:47 AM CANNOT FINAL HAS OTHER FINALS TO COMPLETE | |||
| ELECTRIC FEEDER | 06/22/2009 | APPROVED | LHITES |
| H.V.A.C. FINAL | 06/19/2009 | APPROVED | JHINDMAN |
| GAS FINAL | 06/19/2009 | APPROVED | JHINDMAN |
| DEMOLITION INSPECTION | 06/19/2009 | APPROVED | JHINDMAN |
| FIREWALL FINAL INSPECTION | 06/19/2009 | APPROVED | JPATTEE |
| FLOOR OR WALL PENETRATION | 06/19/2009 | APPROVED | JPATTEE |
| UTILITY COMMERCIAL FINAL | 06/19/2009 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 06/19/2009 | APPROVED | KKING |
| FIRE FINAL | 06/19/2009 | APPROVED | JPATTEE |
| GAS ROUGH | 06/16/2009 | APPROVED | JHINDMAN |
| PLUMBING FINAL | 06/16/2009 | APPROVED | JHINDMAN |
| ELECTRICAL FINAL | 06/15/2009 | CANCELLED BY APPLICANT | RMARVEL |
| ABOVE CEILING | 06/12/2009 | PARTIALLY APPROVED | RMARVEL |
| Note: electrical only. | |||
| 2ND ROUGH ELECTRICAL | 06/12/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Pete called to schedule this inspection Inspection Resulted at 6/12/2009 3:32:51 PM ELECTRICAL IN CEILINGS ARE APPROVED. | |||
| H.V.A.C. ROUGH | 06/12/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| H.V.A.C. ROUGH | 05/22/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/22/2009 10:34:53 AM ED ROOM INSULATION IS OK. LAB ROOM MAIN SUPPLY IS OK TO INSULATE | |||
| H.V.A.C. ROUGH | 05/19/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/19/2009 2:10:08 PM OK TO WRAP DUCTS IN ED ROOM | |||
| 2ND ROUGH ELECTRICAL | 05/07/2009 | PARTIALLY APPROVED | RMARVEL |
| Note: Richard called to schedule this inspection Inspection Resulted at 5/7/2009 2:16:05 PM 2ND ROUGH LAB WALLS ONLY. | |||
| INSULATION INSPECTION | 05/01/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Resulted at 5/1/2009 3:21:04 PM ED ROOM IS OK | |||
| 2ND ROUGH ELECTRICAL | 04/29/2009 | APPROVED | RMARVEL |
| Note: Hooten called to schedule this inspection | |||
| FRAMING | 04/28/2009 | APPROVED | DROCKWELL |
| SECOND ROUGH PLUMBING INSPECTION | 04/27/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/27/2009 4:03:08 PM PARTIAL COPPER AND MED GAS LINES. | |||
| H.V.A.C. ROUGH | 04/22/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/22/2009 3:48:53 PM ED ROOM OK TO WRAP DUCTS. | |||
| FIRST ROUGH PLUMBING INSPECTION | 04/22/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Resulted at 4/22/2009 3:48:53 PM ED ROOM OK EXCEPT S-1. NEED REVISION OF RISER. | |||
| SECOND ROUGH PLUMBING INSPECTION | 04/22/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Resulted at 4/22/2009 3:48:54 PM ED ROOM OK EXCEPT S-1 LAV. | |||
| H.V.A.C. ROUGH | 04/16/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 4/16/2009 12:50:36 PM DUCT RUNOUT SIZES DO NOT MATCH DIFFUSER NECK SIZES PER NOTE ON PLAN. TIGHTEN LOOSE DUCT HANGER STRAPS. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/22/2009 | 06/22/2009 |
| Note: Released By: JMCGOWEN reviewed by Larry H. and checked by Joe M. | |||
| ELEC | HOLD | 06/19/2009 | 06/22/2009 |
| Note: Held By: SKNOPF Revision L1N4 L1Ll Panel revision CITY OF PALM COAST BUILDING DIVISION Comments on Revision to #2009020016 (Emergency Room and Lab Renovation @ 60 Memorial Pkwy) 6/22/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide revised power drawing E211 showing additional circuits/devices for both panels L1CL and L1N4. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 04/02/2009 | 04/02/2009 |
| Note: Released By: JMCGOWEN addendum #1 drawings were created in reponse to the stare (ahca) cmments. | |||
| ELEC | COMPLETE | 04/02/2009 | 04/02/2009 |
| Note: Released By: JMCGOWEN electric revision | |||
| ELEC | COMPLETE | 02/27/2009 | 02/27/2009 |
| Note: Released By: SKNOPF Approved for Release. | |||
| FI1 | COMPLETE | 02/20/2009 | 02/27/2009 |
| Note: Released By: JPATTEE submit to comments | |||
| UD1 | COMPLETE | 02/06/2009 | 02/06/2009 |
| Note: Released By: CJOHNSON | |||
| ELEC | HOLD | 02/05/2009 | 02/05/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2009020016 (Florida Hospital Flagler Emergency Department and Lab Renovation @ 60 Memorial Medical Pkwy) 2/5/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E002 and E003: a. Per NEC 220.87, to use the actual maximum demand as the basis of the load calculation, a full year of demand data must be reviewed, not 30 days. Provide 12 months of actual demand data showing highest demand, or revise Demand Load Calculation to reflect all loads of all sub-panels served by Panels LD1N1 and LD1CA. b. New Panel L1N4 and L1CL are both shown on their respective Risers as 120/208V panels, but both panel schedules and load calculations reflect 277/480V panels. Please revise. 2. E211: a. Lounge 1222 shows a refrigerator on circuit L1CK-19, but load in panel schedule is only represented as a convenience receptacle load. Provide appliance nameplate load per NEC 220.14(A) in panel schedule and update load calculation. b. This sheet shows a refrigerator on circuit L1CL-29 and an ice machine on L1CL-27. Panel schedule only shows convenience outlet loads for both circuits. Provide appliance nameplate load per NEC 220.14(A) in panel schedule and update load calculation. c. Circuit L1CL-25 is shown for a Pyxis system, but load in panel schedule is only shown as a convenience receptacle load. Provide appliance/specific load nameplate load per NEC 220.14(A) in panel schedule and update load calculation. d. A Monitor is shown for typical 'CD' on Detail 3/E211, but load shown is only for 2 convenience receptacles. Provide nameplate load for Monitor plus (1) convenience outlet per NEC 220.14(A) for circuits L1CL-7, 8, 15, 16, 24, and 32. e. Circuit L1CL-23 has monitor plus (4) convenience receptacles on this circuit (3 located at Nurses Station). FBC 419.3.15.7.4 states "There shall be no more than two receptacles per circuit" at each patient station. Revise. f. A TV is shown on circuit L1N1B-17 in addition to (3) convenience receptacles. Provide nameplate load for the TV in addition to the (3) convenience receptacle loads, and update load calculation per NEC 220.14(A). g. NEC 220.14(H) provides (2) options for fixed multi-outlet assembly shown in Equipment Alcove 1047. Revise load in panel per NEC 220.14(H)(2). h. Circuit is not identified on E211 for new NCMS shown on E411. Provide circuit and update panel load. 3. E311: a. Provide updated panel schedules for Panels H1CA and H1SB to reflect revised lighting circuits. b. Circuit L1N4-16 is shown for (4) convenience receptacles on Sheet E211, and for new recessed fluorescent lighting on E311. Update panel circuit identification and loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| FI1 | HOLD | 02/05/2009 | 02/06/2009 |
| Note: Held By: JPATTEE Plans submitted on February, 3rd 2009 do not comply with the Florida Fire Prevention Code adopted December, 31 2008. Review and ammend to comply with new adopted codes. | |||
| MECH | COMPLETE | 02/05/2009 | 02/05/2009 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 02/05/2009 | 02/05/2009 |
| Note: Released By: FREODICA | |||
| ZON | COMPLETE | 02/03/2009 | 02/03/2009 |
| Note: Released By: ECOYNE | |||
| BLD | COMPLETE | 02/03/2009 | 02/04/2009 |
| Note: Released By: JJOSEPH |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 06/26/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REVISION | ¤40.00 | 04/21/2009 |
| REINSPECTION FEE | ¤40.00 | 04/21/2009 |
| SITE PLAN 20 | ¤20.00 | 03/10/2009 |
| ADMIN COMMERCIAL | ¤60.00 | 03/10/2009 |
| ELECTRIC FEE | ¤360.00 | 03/10/2009 |
| FIRE PLANS REVIEW | ¤30.00 | 03/10/2009 |
| MECHANICAL FEE | ¤360.00 | 03/10/2009 |
| PERMIT FEE | ¤3,500.00 | 03/10/2009 |
| PLAN CHECK FEE | ¤575.00 | 03/10/2009 |
| PLUMBING FEE | ¤360.00 | 03/10/2009 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤5,425.00 |