Permit #2009030549
Permit Details
Status: COED
| Parcel Id: 09-12-31-5117-00000-0030 |
| COMMERCIAL SQUARE FOOTAGE: 3800 sqft |
| Total Square Footage: 3800 sqft |
| Block: 00000 |
| Subdivision: 2121 - Pinnacles Professional Park |
| Job Phone: 386-437-4699 |
| Location Address: 140 PINNACLES DR |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 05/18/2009 |
| NOC: RECORDED |
| Applicant name: RICHARD JAMES SMITH |
| Owner: D & D MEDICAL BUILDING ASSO LLC |
|
Address 6 OFFICE PARK DRIVE PALM COAST, FL 32137 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤551,000.00 |
| Job Description: 2 STORY MEDICAL CLINIC - "MEDIQUICK" SP-WVR-08-15 |
| Type: CN |
Contractor
HAMMOCK COMMUNITIES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
725 NORTH OCEANSHORE BLVD FLAGLER BEACH, FL 32136 |
CGC1516033 (Exp: 08/31/2026) | 386-693-4947 |
Sub Contractors
KIPP S GARDNER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO Box 1350 Bunnell, FL 32110 |
EC0001298 (Exp: 08/31/2018) | (386) 437-3369 | (386)437-5228 |
THOMAS P MCGUIRE JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
935 ALEXANDER AVE PORT ORANGE, FL 32119 |
CAC012263 (Exp: 08/31/2026) | 386-767-3900 | 386-761-1205 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
PAUL SCOTT WEISS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
129 W. Marion Ave. EDGEWATER, FL 32132 |
CCC057555 (Exp: 08/31/2025) | 386-788-7750 | (386)423-3030 |
Inspection History
| Type | Request Date | Result | Inspector |
| ENGINEERING FINAL | 11/24/2009 | APPROVED | MCOBB |
| TRAFFIC ENGINEER | 11/24/2009 | APPROVED | MCOBB |
| UTILITY COMMERCIAL FINAL | 11/19/2009 | APPROVED | DSPENCER |
| UTILITY COMPANY FINAL | 11/19/2009 | APPROVED | DSPENCER |
| LANDSCAPE FINAL | 11/19/2009 | APPROVED | WBUTLER |
| Note: THIS IS A REINSPECTION | |||
| LANDSCAPE FINAL | 11/17/2009 | PARTIALLY APPROVED | WBUTLER |
| Note: Irrigation as-built needs to be modified to more closely reflect the on-site installation location of heads and zones. One signed and sealed copy is needed of the revised sheet. | |||
| COMMERCIAL BUILDING FINAL | 11/16/2009 | FINAL APPROVED | CMINI |
| ELECTRICAL FINAL | 11/13/2009 | APPROVED | RMARVEL |
| FIRE FINAL | 11/12/2009 | APPROVED | JPATTEE |
| PLUMBING FINAL | 10/30/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 10/28/2009 | CANCELLED BY APPLICANT | JHINDMAN |
| H.V.A.C. FINAL | 10/28/2009 | APPROVED | JHINDMAN |
| ELECTRIC FEEDER | 09/18/2009 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 9/18/2009 2:56:18 PM CHECKED TORQUE ON FEEDER PANEL. | |||
| COMMERCIAL POWER INSPECTION | 09/18/2009 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 9/18/2009 2:56:18 PM STIRLING ANDASSOCIATES | |||
| ABOVE CEILING | 09/17/2009 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Resulted at 9/17/2009 1:25:43 PM MECHANICAL ONLY | |||
| ABOVE CEILING | 09/17/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION above ceiling electric | |||
| INSULATION INSPECTION | 08/03/2009 | APPROVED | CMINI |
| SECOND ROUGH PLUMBING INSPECTION | 07/24/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| 2ND ROUGH ELECTRICAL | 07/23/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/23/2009 10:45:03 AM WALLS ONLY | |||
| 2ND ROUGH ELECTRICAL | 07/22/2009 | PARTIALLY APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/22/2009 3:26:17 PM INNER WALLS ONLY. | |||
| 2ND ROUGH ELECTRICAL | 07/17/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/17/2009 2:39:43 PM 300.4 WHERE ENT RACEWAYS ARE WITHIN 1.25IN OF EDGE OF FRAMING MEMBER IT NEEDS TO BE PROTECTED AS MENTIONED IN PRIOR LIST. THE STRAPPING OF ONE RACEWAY TO ANOTHER RACEWAY THE WAY YOU HAVE IT DOES NOT MEET THE REQUIREMENTS OF 300.11(B)1)2)3) | |||
| 2ND ROUGH ELECTRICAL | 07/15/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Mark called to schedule this inspection Inspection Resulted at 7/15/2009 3:22:52 PM STRAP ENT EVERY 3FT. PROTECT ENT WHERE WITHIN 1 1/4IN FROM EDGE OF FRAMING MEMBER. MISSING K.O. PLUG. STRAP EMT WITHIN 3FT OF ENCLOSURE. | |||
| SECOND ROUGH PLUMBING INSPECTION | 07/15/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Mark called to schedule this inspection Inspection Resulted at 7/15/2009 2:55:00 PM VENT SYSTEM DOES NOT MATCH PLANS. | |||
| H.V.A.C. ROUGH | 07/15/2009 | APPROVED | JHINDMAN |
| Note: Mark called to schedule this inspection | |||
| FRAMING | 07/15/2009 | APPROVED | CMINI |
| Note: Mark called to schedule this inspection | |||
| ROOF IN PROGRESS | 07/07/2009 | APPROVED | CMINI |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/18/2009 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/18/2009 3:19:41 PM NEED REVISION FOR CHANGE OF STAIR DETAIL AND REVISION FOR CHANGE OF 2- 2X12 RIDGE TO 1 - 2X12.CHECK ON FRAMING. | |||
| LINTEL | 06/05/2009 | APPROVED | CMINI |
| FOUNDATION SURVEY APPROVED BY ZONING | 06/04/2009 | APPROVED | BBARTON |
| Note: As-Built checked by Larry Torrino | |||
| TEMPORARY POLE | 06/01/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/1/2009 1:06:42 PM STIRLING AND ASSOCIATES | |||
| FOOTER | 05/29/2009 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/29/2009 3:22:58 PM FOOTER FOR SIGN | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 05/29/2009 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FOOTER | 05/28/2009 | CANCELLED BY APPLICANT | CMINI |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/28/2009 | CANCELLED BY APPLICANT | CMINI |
| UNDERGROUND ELECTRICAL | 05/28/2009 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 5/28/2009 2:03:27 PM UNDERSLAB ONLY | |||
| TEMPORARY POLE | 05/28/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 5/28/2009 2:03:27 PM CANNOT USE NM CABLE IN WET LOCATIONS IF NOT RATED FOR THAT LOCATION. METER CAN COONECTIONS ARE SEVERELY CORRODED AND IN A UNSAFE CONDITION NEEDS REPLACED. | |||
| UNDERGROUND ELECTRICAL | 05/27/2009 | APPROVED | RMARVEL |
| FIRST ROUGH PLUMBING INSPECTION | 05/22/2009 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/19/2009 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 5/19/2009 2:10:07 PM CANNOT DETERMINE IF SANITARY PIPING IS LEAKING DUE TO THE HEAVY RAINS THAT ARE FILLING UP THE VENT STACKS. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 11/12/2009 | 11/12/2009 |
| Note: Released By: LHITES Revision re circuit | |||
| ELEC | HOLD | 11/10/2009 | 11/10/2009 |
| Note: Held By: LHITES electric revisions - re-circuit Revision sheets must be signed and sealed by engineer. circuit P1-19 is for x-ray room. Panel schedule says it is for exam room 3. please correct. | |||
| PLUM | COMPLETE | 07/22/2009 | 07/23/2009 |
| Note: Released By: JMCGOWEN Isometric changes | |||
| MECH | COMPLETE | 07/14/2009 | 07/14/2009 |
| Note: Released By: FREODICA REQUEST FOR 2ND SET OF PLANS Revisions: 1. Building & mechanical charge $80.00 2. Mech- Revised AHU installation and ductwork. 3. Bldg.- Added covered entry at front door, etc. See listing. | |||
| ZON | COMPLETE | 07/14/2009 | 07/14/2009 |
| Note: Released By: ECOYNE revision for front door covered entrance 8' X 4' | |||
| BLD | COMPLETE | 07/10/2009 | 07/13/2009 |
| Note: Released By: JJOSEPH revision - framing changes, air handler changes, fire- directions of travel change | |||
| MECH | HOLD | 07/10/2009 | 07/10/2009 |
| Note: Held By: FREODICA revision - framing changes, air handler changes, fire- directions of travel change 1. Provide another one(1) set of revision plans. | |||
| FD1 | COMPLETE | 07/09/2009 | 07/10/2009 |
| Note: Released By: JPATTEE revision - framing changes, air handler changes, fire- directions of travel change | |||
| BLD | COMPLETE | 06/08/2009 | 06/08/2009 |
| Note: Released By: JJOSEPH highlighted trusses have been changed to product or 'Dutch Hoz" at front of building. | |||
| ELEC | COMPLETE | 05/07/2009 | 05/07/2009 |
| Note: Released By: SKNOPF Approved for Release. | |||
| MECH | COMPLETE | 05/07/2009 | 05/07/2009 |
| Note: Released By: FREODICA response to comments | |||
| FI1 | COMPLETE | 05/01/2009 | 05/01/2009 |
| Note: Released By: JPATTEE correction - fire updates to the holds | |||
| BLD | COMPLETE | 04/30/2009 | 04/30/2009 |
| Note: Released By: JJOSEPH | |||
| FI1 | HOLD | 04/29/2009 | 04/30/2009 |
| Note: Held By: JPATTEE correction - for all areas on hold Rooms 120, 115, 110 exceed allowable swing into corridor. Minimum tread depth is 11". Provide listing agency for rated closet # 116 Exit lighting still appears to be lacking on the first floor. Does a code allow for an electrical room to be unfinished and expose combustible materials? | |||
| BLD | HOLD | 04/27/2009 | 04/28/2009 |
| Note: Held By: JJOSEPH According to the Florida Product Approval Number 11638, the exterior door is not impact resistant then needs to be protected. | |||
| PLUM | COMPLETE | 04/27/2009 | 04/28/2009 |
| Note: Released By: FREODICA correction - for all areas on hold | |||
| ELEC | HOLD | 04/27/2009 | 04/27/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2009030549 (Medi-Quick Walk-In Clinic) 4/27/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Sheet 4/19: Previous comments from 4-7-2009 1) Completed b. The following devices/items have no circuit shown on plans: 1) Completed 2) Completed 3) Completed 4) Completed 5) Completed 6) Completed 7) All emergency lights 8) Completed 9) Completed 10) GFCI receptacle on exterior wall outside room 107 11) Completed c. Completed d. Completed e. Disconnect will be required for Water Heater in 201. f. Completed g. Completed h. Revise Demand Load Calculation per NEC for each panel and for service entrance feeders. Demand load calculation given for both panels has incorrect quantity of 180VA convenience receptacles, and does not take into account equipment loads, ie. refrigerators, exhaust fans, copiers, fax machines, x-ray machine, etc. Equipment and appliances must be included at rated load per NEC 220.14(A). i. Plumbing plan shows water heater has (2) 4500W elements total 9000W @ 240V yielding 38A. Revise circuit breaker size as required per nameplate for water heater P1-26:28, and revise load in load calculation. j. Provide electrical data for AHU's, ACU's, Mitsubishi Mini-split, and exhaust fans for circuit breaker size requirements and load determination. None provided. k. Completed l. Completed m. Completed n. Completed o. Completed p. Completed 2. New Comments from revised plan 4/19: a. Circuit P1-2 shows 10 duplex receptacles @ 180VA plus (5) 'A' fixtures @ 128W yielding 2440W on a 20A circuit. Revise circuit breaker size or adjust load. b. Circuit p1-8 is shown for 2 refrigerators, rooms 100 and 111. Revise circuit load and load calculation to reflect both appliances. c. Circuit P2-15 is shown for duplex receptacles and lighting in room 203, but panel schedule is shown as "space". Review and revise. Include load for this circuit. d. Identify circuit breaker size for mini-split. e. Revise circuit load for circuit P1-32 shown room 100, 101 and 112. f. The following circuits have incorrect load shown in panel schedules: 1) P1-4, 29, 32, 33 2) P2-5, 9 …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | HOLD | 04/27/2009 | 04/27/2009 |
| Note: Held By: FREODICA Comments to submitted corrections dated April 23, 2009: 1. Item 1: Energy calculations shall be signed by the preparer. Also, the input data report is missing. 2. Item 3: Identify on plan all exhaust fans to match Equipment Schedule. The exhaust duct termination from dark room shall be at least 10 ft away from outside air intake for AHU-1 & AHU-2. 3. Item 10: Condensate drain disposal from AHU-2 shows passing down along the window? Plase clarify. How about the condensate drain from AHU-1. | |||
| UD1 | COMPLETE | 04/22/2009 | 04/22/2009 |
| Note: Released By: CJOHNSON | |||
| ZON | COMPLETE | 04/14/2009 | 04/14/2009 |
| Note: Released By: ECOYNE | |||
| FI1 | HOLD | 04/07/2009 | 04/08/2009 |
| Note: Held By: JPATTEE Cover sheet, Maximum dead end corridor is incorrect. Closet 116 required to be fire rated Provide stair construction type. Sheet 3/19 rooms 201, 202, 203 are indicated as unfinished. Does room 106 require wall shielding for x-ray? Rooms 120, 115, 110 doors exceed allowable swing into corridor. Exit lighting appears to be lacking. Plans do not indicate fire rated walls, room 205 shows a 1 hour rated door?? | |||
| MECH | HOLD | 04/06/2009 | 04/07/2009 |
| Note: Held By: FREODICA 1. Revise energy calculations to comply with the new code FBC 2007 using Form 400B-07 for method B per Section 13-400.3.B. 2. The energy calculations show (1) 1-ton unit split-system which is not shown on the plan. Please clarify. 3. Provide exhaust fan specifications, duct size, routing or termination. 4. Provide size of louver for outside air and indicate the amount of air in CFM supplied to each AHU. 5. Provide return air from office adjacent to waiting room. 6. Provide information on dark room as there is no return or exhaust air shown. 7. Indicate return duct sizes on first floor plan for both AHU-1 & AHU-2. 8. Indicate supply/return duct sizes on attic plan for AHU-2. 9. Provide material specifications for ductwork system. 10. Provide condensate disposal per FMC 2007 Section 307. | |||
| PLUM | HOLD | 04/06/2009 | 04/07/2009 |
| Note: Held By: FREODICA 1. Provide material specifications for DWV and domestic water (hot & cold). 2. Provide pipe sizes on domestic water either on plan or riser diagram. | |||
| ELEC | HOLD | 04/06/2009 | 04/07/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2009030549 (Medi-Quick Walk-In Clinic) 4/7/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Sheet 4/19 signed and sealed 11-13-08: a. The following circuits are shown tied together: 1) P1-1 to P1-3 2) P1-19 to P1-23 3) P1-11 to P1-13 4) P1-9 to P1-12 b. The following devices/items have no circuit shown on plans: 1) GFCI, lighting, exhaust fan, and ceiling receptacle in Dark Room 2) Light in Chart Storage 3) Duplex receptacle in Corridor outside Chart Storage 4) Light in Closet 116 5) Lighting in stairs 6) Lighting, exhaust fan, receptacle in Drug Testing 7) All exit and emergency lights 8) Service receptacle at ACU's. 9) Interior lighting 10) GFCI receptacle on exterior wall outside room 107 11) Lighting and exhaust fan in room 102 Employee's lavatory c. Match lighting Sheet 4 to lighting Sheet 8. Reflected ceiling does not coincide with quantity of fixtures on Electrical Plan. d. Exit and emergency lighting will be required in room 204, and exit lighting will be required at top of stairs in 205. e. Disconnects will be required for AHU-1, AHU-2, and Water Heater in 201. f. Lighting fixture in 205 at door to periphery unfinished area needs circuit. g. Provide Fixture schedule showing total wattage for each fixture. h. Provide Demand Load Calculation per NEC for each panel and for service entrance feeders. i. Plumbing plan shows water heater is (2) 4500 total 9000W @ 240V yielding 38A. Revise circuit breaker size as required per nameplate for water heater P1-26:28. j. Provide electrical data for AHU's, ACU's, Mitsubishi Mini-split, and exhaust fans for circuit breaker size requirements and load determination. k. Electrical Riser shows 1PH meter can, but Note 1 shows 4 conductors. Revise feeder from FPL to meter, since grounding electrode appears to be developed at the meter. l. Identify size of grounding electrode conductor and quantity and type of grounding electrodes per NEC 250. m. Identify location of meter and service wireway on power plans. n. Provide loads in panel schedules for all circuits. o. Identify X-ray equipment load per nameplate rating. p. Sheet 5 Panel P2 identifies panel as 3-phase 4-wire. Sheet 4 P2 panel schedule shows 1-phase 3-wire. Coordinate. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | HOLD | 04/03/2009 | 04/06/2009 |
| Note: Held By: JJOSEPH 1.Provide Statement of 2007 Florida Building Code as the design code. 2.Provide the LVLSs size. 3. Provide Florida Product Approval Number for all doors and windows. 4.The wall and soffits within enclosed usable spaces under enclosed and unenclosed stairways need to be protected per section 1009.5.3 of FBC 2007. 4.Any door swinging in a means of egress shall leave unobstructed at least one half of the required width of a corridor per section 1008.1.8.8 of FBC 2007. 5. Two roof coverings were sumbmitted (Asphalt shingle and metal) wich one that will be used for that project. 6. Provide the correct Dead End Corridor distance per section 1017.3 (2) of FBC 2007 7.Provide Floor Joists details 8. Identify Area of Rescue Assistance location. 9. Precise the construction type ( IIIA or IIIB) 10.Provide two stories wall section details. 11. Others comments may be necessary based on your responses to these comments. | |||
| ZON | HOLD | 04/01/2009 | 04/01/2009 |
| Note: Held By: ECOYNE need approved site plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/07/2009 |
| REINSPECTION FEE | ¤40.00 | 12/07/2009 |
| REINSPECTION FEE | ¤40.00 | 12/07/2009 |
| REINSPECTION FEE | ¤40.00 | 12/07/2009 |
| REINSPECTION FEE | ¤40.00 | 12/07/2009 |
| REVISION | ¤40.00 | 12/07/2009 |
| REVISION | ¤40.00 | 12/07/2009 |
| REVISION | ¤40.00 | 12/07/2009 |
| REVISION | ¤80.00 | 12/07/2009 |
| TRANSPORTATION IMPACT FEE | ¤10,053.36 | 12/07/2009 |
| TRANSPORTATION IMPACT FEE | ¤20,106.70 | 12/07/2009 |
| REVISION | ¤80.00 | 05/18/2009 |
| SITE PLAN 20 | ¤20.00 | 05/18/2009 |
| TRANSPORTATION IMPACT FEE | ¤10,053.36 | 05/18/2009 |
| ADMIN COMMERCIAL | ¤60.00 | 05/18/2009 |
| BUILDING CODE ADMIN FUND | ¤19.00 | 05/18/2009 |
| ELECTRIC FEE | ¤390.60 | 05/18/2009 |
| FIRE PLANS REVIEW | ¤38.00 | 05/18/2009 |
| FIRE IMPACT FEE RES 4/01/08 | ¤2,004.12 | 05/18/2009 |
| MECHANICAL FEE | ¤390.60 | 05/18/2009 |
| PERMIT FEE | ¤3,030.50 | 05/18/2009 |
| PLAN CHECK FEE | ¤633.65 | 05/18/2009 |
| PLUMBING FEE | ¤390.60 | 05/18/2009 |
| RADON FEE | ¤19.00 | 05/18/2009 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤47,689.49 |