Permit #2009050642

Permit Details

Status: COED

Parcel Id: 07-11-31-1090-00000-00B0
Total Square Footage: 1260 sqft
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: 386-585-0410
Location Address: 160 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 06/26/2009
NOC: Unknown
Applicant name: THOMAS M SCAGLIONE
Owner: ASNACO LLC

Address

C/O INTERSTATE HOLDINGS INC

PALM COAST, FL 32746

Address

1307 S INTERNATIONAL PKWY SUITE 2051

PALM COAST, FL 32746

Contracted Stated Job Value: ¤15,000.00
Job Description: BLDG. A UNIT 105 -- INTERIOR BUILDOUT FOR "LIFE THYME CAFE & WELLNESS"
Type: CN

Contractor

T-CON GROUP, INC.
Status Location Address State License Number Phone
CANCEL

3246 NORTH POWERLINE ROAD

POMPANO BEACH, FL 33069

CBC1251999 (Exp: 08/31/2020) 954-825-8369

Sub Contractors

JOHN R JOHNSON
Status Location Address State License Number Phone Fax
CANCEL

12 SEAMAN TRAIL EAST

PALM COAST, FL 32164

ER13012527 (Exp: 08/31/2014) (386)627-0236 (386) 586-5944
RANDALL BRADEN GUENOT
Status Location Address State License Number Phone Fax
CANCEL

3788 FIR CT

ORMOND BEACH, FL 32174

CAC057646 (Exp: 08/31/2010) (386)677-9632 (386)677-0165
AARON JOSHUA CRANDALL
Status Location Address State License Number Phone
INACTIVE

1519 SOUTH DAYTONA AVE

PALM COAST, FL 32164

CFC1425974 (Exp: 08/31/2026) 386-931-6329

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 10/23/2009 APPROVED CMINI
Note: THIS IS A REINSPECTION
COMMERCIAL BUILDING FINAL 10/23/2009 FINAL APPROVED CMINI
FIRE FINAL 10/21/2009 APPROVED - AS NOTED JPATTEE
Note: Lower or remove shelf under sprinkler head
ELECTRICAL FINAL 10/20/2009 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 10/20/2009 1:19:49 PM NEED TO SHOW DELETED AND ADDED RECEPTACLES AND SWITCHES TO MATCH PLAN WITH REVISION.....ALL CHECKED TO BE IN WORKING ORDER AND PANEL CHECKED AND MATCHES SCHEDULE.
UTILITY COMMERCIAL FINAL 10/19/2009 APPROVED DSPENCER
UTILITY COMPANY FINAL 10/19/2009 APPROVED DSPENCER
H.V.A.C. FINAL 10/16/2009 APPROVED JHINDMAN
PLUMBING FINAL 10/16/2009 APPROVED JHINDMAN
MONOLITHIC SLAB INSPECTION/SLAB 09/18/2009 APPROVED CMINI
ABOVE CEILING 09/16/2009 APPROVED JHINDMAN
FRAMING 09/11/2009 APPROVED LHITES
ABOVE CEILING 09/09/2009 APPROVED - AS NOTED JHINDMAN
Note: Inspection Resulted at 9/9/2009 3:14:45 PM MECHANICAL ONLY. MECHANICAL ABOVE CEILING IS OK. WILL CHECK EXPOSED DRYER VENT AT FINAL.
H.V.A.C. ROUGH 09/09/2009 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 09/09/2009 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
2ND ROUGH ELECTRICAL 09/09/2009 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
COMMERCIAL POWER INSPECTION 09/09/2009 APPROVED RMARVEL
Note: Inspection Resulted at 9/9/2009 3:38:11 PM JOHN JOHNSON ELECTRIC.
2ND ROUGH ELECTRICAL 09/03/2009 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 9/3/2009 9:13:54 AM STILL WORKING. NOT READY.
FIRST ROUGH PLUMBING INSPECTION 08/24/2009 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 8/24/2009 2:50:40 PM WASHING MACHINE SANITARY CONNECTION IS NOT PER THE RISER PLAN. GREASE LINE IS OK.

Review History

Department Status Date In Date Out
ELEC COMPLETE 10/22/2009 10/22/2009
Note: Released By: LHITES Revision Plans to reflect As-Built
ELEC COMPLETE 10/09/2009 10/09/2009
Note: Released By: LHITES move switch from next to door as noted on E-02 changed from circuit # 31 to # 33 moved receptacle and changed to j-box as noted on E-02
PLUM COMPLETE 09/04/2009 09/04/2009
Note: Released By: FREODICA correction to the revision- wash machine dump stack changes, laundry tub vent changes
MECH COMPLETE 08/31/2009 08/31/2009
Note: Released By: FREODICA Revision: Supply and return ductwork.
BLD COMPLETE 08/26/2009 08/26/2009
Note: Released By: JJOSEPH Revision Relocate pocket door, add door. Changed washer drain to drain at existing Lav. Drain Added dryer vent, added 10" flex on drawing relocate return air
MECH HOLD 08/26/2009 08/26/2009
Note: Held By: FREODICA Revision comment: 1. How is return air from Treatment Room 01, Waiting Room 02 and Office Room 06 would be accomplished.
PLUM HOLD 08/26/2009 08/26/2009
Note: Held By: FREODICA 1. Waste connection of new washing machine standpipe to existing 2" wet drain/vent is not allowed per FPC 2007 code Section 406.3 2. On grease line system, where air admitance valves (auto vents) are used, there shall be at least one (1) stack vent or vent stack extended outdoor to the open air per FPC 2007 Section 917.7.
ELEC COMPLETE 06/25/2009 06/25/2009
Note: Released By: SKNOPF Correction of circuits, load calculations Approved for Release.
FI1 COMPLETE 06/23/2009 06/23/2009
Note: Released By: BMEYERS
ELEC HOLD 06/22/2009 06/22/2009
Note: Held By: SKNOPF Correction Provided circuit labels load calcs riser diagram CITY OF PALM COAST BUILDING DIVISION Comments on Permit App. #2009050642 (Life Thyme Café & Wellness @ Unit A105 160 Cypress Point Pkwy) 6/22/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E-01: a. Three new type "LT-05" lights are not circuited. b. Verify lighting load on circuit 2. c. Identify circuits and load for (2) ceiling fans. 2. E-02: a. Review load on circuits 1 and 33 and update panel. b. Item E-22 Refrigerator has no circuit identified on plans. Update this 2nd refrigerator load in Demand Load Calculation. c. Provide a circuit for receptacle in room with D-05 pocket door. d. Provide a circuit/device for Dishwasher Item E-18. Provide dishwasher load in Demand Load Calculation. e. Circuits 31 and 34 are listed in panel schedule as receptacles, but circuits are not shown on plans. 3. E-03: a. Revise minimum lighting demand load in load calculation for stores (FBC "merchantile") per NEC Table 220.12. b. Appliance coffee machine circuit 24 is not shown in load calculation per NEC 220.14(A). c. Existing plans on file show both the AHU and the CU loads are each larger than the 2.3KVA shown in the load calculation. Please review and revise. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD COMPLETE 06/22/2009 06/25/2009
Note: Released By: JJOSEPH Corrections on LS-01 Load calculation formula corrected Egress clarified
UD1 COMPLETE 06/11/2009 06/15/2009
Note: Released By: CJOHNSON
FI1 COMPLETE 06/10/2009 06/11/2009
Note: Released By: BMEYERS Held By: JPATTEE Sheet LS-01 under building information indicate NFPA 101 2003, plans shall comply with NFPA 101 2006 edition. Sheet LS-01, occupant load calculation formula is incorrect. Exit through RM-01 area does not appear to comply with NFPA 101, 7.5.2.1. Unable to determine difference indicated by sprinkler legend, what is new or existing.
ELEC HOLD 06/09/2009 06/10/2009
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2009050642 (Life Thyme Café & Wellness @ 160 Cypress Point Pkwy) 6/10/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E-01 and E-02: Provide circuits on plans. 2. E-03: a. Provide Demand Load Calculation per NEC 220. b. Provide specific appliance/equipment loads and appliance/equipment identification in the panel schedule per NEC 220.14(A) and 408.4. 3. Provide Single Line Electrical Riser Diagram. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
PLUM COMPLETE 06/09/2009 06/09/2009
Note: Released By: FREODICA
BLD COMPLETE 06/08/2009 06/08/2009
Note: Released By: JJOSEPH submitted stamp enginner drawings that was missing
MECH COMPLETE 06/08/2009 06/09/2009
Note: Released By: FREODICA
BLD HOLD 05/27/2009 05/27/2009
Note: Held By: JJOSEPH Interior Designer or Architect stamp is required before processing to the plan review .
ZON COMPLETE 05/27/2009 05/27/2009
Note: Released By: BBARTON interior alterations only

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/23/2009
REINSPECTION FEE ¤40.00 10/23/2009
REINSPECTION FEE ¤40.00 10/23/2009
REVISION ¤40.00 10/23/2009
REVISION ¤40.00 10/23/2009
REVISION ¤40.00 10/23/2009
REVISION ¤40.00 10/23/2009
REVISION ¤40.00 10/23/2009
SITE PLAN 20 ¤20.00 06/26/2009
ADMIN COMMERCIAL ¤60.00 06/26/2009
BUILDING DISCOUNT 100% (¤424.80) 06/26/2009
ELECTRIC FEE ¤69.00 06/26/2009
FIRE PLANS REVIEW ¤25.00 06/26/2009
MECHANICAL FEE ¤69.00 06/26/2009
PERMIT FEE ¤105.00 06/26/2009
PLAN CHECK FEE ¤100.00 06/26/2009
PLUMBING FEE ¤69.00 06/26/2009
Fees Total Due: ¤0.00 Total Paid: ¤412.20