I want to search for...
Permit #2009070212
Permit Details
Status: COED
| Parcel Id: 07-11-31-7003-00110-0180 |
| CONDITIONED SPACE: 2530 sqft |
| GARAGE: 453 sqft |
| OPENED PORCH (WITH ROOF) : 108 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| Total Square Footage: 3158 sqft |
| Block: 00110 |
| Subdivision: 2190 - SECTION 3 |
| Job Phone: 386-246-6125 |
| Location Address: 21 CLASSIC CT S |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/28/2009 |
| NOC: RECORDED |
| Applicant name: BRIAN ANDREW GAZZOLI |
| Owner: GLADKOVA GALINA |
|
Address BLDG 2 APT 54 MOSCOW, 0 |
|
Address 1/2 SOLYANKA STREET MOSCOW, 0 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤214,316.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SEAGATE HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
185 CYPRESS POINT PARKWAY Palm Coast, FL 32137 |
SUITE 7 Palm Coast, FL 32137 |
CRC057202 (Exp: 08/31/2010) | 386-246-6125 | 386-246-6124 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
KENNETH MARTIN REED
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
83 LANCELOT DRIVE BUNNELL , FL 32110 |
CCC1328712 (Exp: 08/31/2026) | 386-446-3100 | 386-445-6074 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/17/2009 | FINAL APPROVED | DROCKWELL |
| Note: 12/18/09 (JB) NEED TO INSTALL IRRIGATION RAIN SENSOR. 12/19/09 (JB) SENSOR INSTALLED APPROVED LANDSCAPING. | |||
| STORMWATER FINAL INSPECTION | 12/09/2009 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION 12/9/09 22 sq ft road damage $276// seed and straw disturbed areas of vacant lot 12/17/09 road repaired//la//12/21/09 per DR | |||
| UTILITY COMPANY FINAL | 12/04/2009 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 12/04/2009 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: 8/26/09 site check ok no silt fence needed there is a swale at rear of property along seawall 12/4/09: 1. Grade, seed and straw adjacent properties (see photo) 2.Clean road at edge of pavement 3.Remove concete from adjacent property 4. general cleanup 5. need to stabilize dirt area wahout from right side of seawall 6. landscaping between a/c pad and pool pad blocking drainage to front swale | |||
| PRE DRIVEWAY | 11/17/2009 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Make sure there is a 6" footing at the edge of the pavement along total width of driveway | |||
| RESIDENTIAL EARLY POWER | 11/02/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 11/2/2009 1:53:06 PM PALMETTO. CALLED FPL AT 1:50 | |||
| RESIDENTIAL EARLY POWER | 10/30/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 10/30/2009 3:01:01 PM OPEN NM CABLE HANGING OUT OF WALL UNPROTECTED AT SIDE REAR OF HOME. IT NEEDS TO BE BOXED AND BLANKED FOR EARLY POWER. | |||
| LATH /BRICK FLASHING | 10/15/2009 | APPROVED | CMINI |
| INSULATION INSPECTION | 10/08/2009 | APPROVED | DROCKWELL |
| ALL ROUGH | 10/06/2009 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 10/6/2009 12:20:07 PM INSTALL MISSING RETURN AIR GRILLES AT BEDROOMS/SEAL DRYER DUCT AT CONNECTION THRU ROOF | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/06/2009 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/02/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 10/2/2009 12:44:49 PM 2X4``S SUPPORTING AHU SHOULD EXTEND TRUSS TO TRUSS AS PER PLAN-NOT SUPPORT ON BACKFRAMING/FIREBLOCK ABOVE ARCH``ES/TIGHTEN ALL SHOE PLATE BOLTS/STRAP HOLDING DOWN ROOF ABOVE NOT FASTENED AT FRONT BEDROOM/ANCHOR TRUSSE``S T-26 T17 AND T-3 TO LINTEL. | |||
| LINTEL | 09/02/2009 | APPROVED | DROCKWELL |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 09/01/2009 | APPROVED | WKINELL |
| FOUNDATION SURVEY APPROVED BY ZONING | 09/01/2009 | APPROVED | BBARTON |
| MONOLITHIC SLAB INSPECTION/SLAB | 08/26/2009 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 08/25/2009 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/01/2009 | 10/01/2009 |
| Note: Released By: JJOSEPH truss repairs | |||
| SW1 | COMPLETE | 07/28/2009 | 07/28/2009 |
| Note: Released By: LAPTEKAR Received grade elevation profile | |||
| BLD | COMPLETE | 07/17/2009 | 07/17/2009 |
| Note: Released By: JMCGOWEN correction - trusses reviewed by auba and check by joe m. | |||
| BLD | HOLD | 07/15/2009 | 07/15/2009 |
| Note: Held By: JJOSEPH 1. Provide Hangers/straps schedule for specific Job. 2. Provide load capability verification of trusses carring Air Handler UNIT. | |||
| ZON | COMPLETE | 07/14/2009 | 07/14/2009 |
| Note: Released By: ECOYNE correction - planting wrap around | |||
| SW1 | HOLD | 07/13/2009 | |
| Note: Held By: LAPTEKAR A grade elelvation profile is required for salt water canal lots. faxed 7/13 emailed 7/17 | |||
| ZON | HOLD | 07/10/2009 | |
| Note: Held By: ECOYNE planting must wrap around right corner of home |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 12/17/2009 |
| EARLY POWER INSPECTION | ¤40.00 | 12/17/2009 |
| CONTRACTOR CHANGE | ¤40.00 | 12/17/2009 |
| REINSPECTION FEE | ¤40.00 | 12/17/2009 |
| REINSPECTION FEE | ¤40.00 | 12/17/2009 |
| REVISION | ¤40.00 | 12/17/2009 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/17/2009 |
| TRANS IMPACT FEE 6 - RESIDENTI | ¤3,841.11 | 07/28/2009 |
| BUILDING CODE ADMIN FUND | ¤15.79 | 07/28/2009 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/28/2009 |
| SITE PLAN 20 | ¤20.00 | 07/28/2009 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/28/2009 |
| NEW RESIDENTIAL INSPECTIONS | ¤524.00 | 07/28/2009 |
| BUILDING DISCOUNT 100% | (¤1,170.36) | 07/28/2009 |
| ELECTRIC FEE | ¤217.20 | 07/28/2009 |
| FIRE COMM IMPACT FEE 4/1/09 | ¤190.48 | 07/28/2009 |
| MECHANICAL FEE | ¤217.20 | 07/28/2009 |
| PERMIT FEE | ¤20.00 | 07/28/2009 |
| PARKS IMPACT FEE 4/1/09 | ¤1,230.83 | 07/28/2009 |
| PLAN CHECK FEE | ¤104.80 | 07/28/2009 |
| PLUMBING FEE | ¤217.20 | 07/28/2009 |
| RADON FEE | ¤15.79 | 07/28/2009 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,399.04 |