I want to search for...

Permit #2009070471

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7034-00640-0020
Block: 00640
Subdivision: 2166 - Section 31
Job Phone: (386) 445-2222
Location Address: 9 ELLINGTON DR
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 07/28/2009
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: RAGSDALE, DAVID M & WILMA

Address

9 ELLINGTON DRIVE

PALM COAST, FL 32164

Lot: 0020
Contracted Stated Job Value: ¤12,000.00
Job Description: KITCHEN REMODEL
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 10/13/2009 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 10/13/2009 FINAL APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ELECTRICAL FINAL 09/18/2009 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 9/18/2009 2:45:11 PM ELECTRIC ON PENNINSULA IS NOT PER PLAN AND CODE. ICANNOT DETERMINE IF THE POWER STRIP IS RATED FOR THE APPLICATION YOU ARE USING IT FOR. RECEPTACLES ARE REQUIRED ON THE BACK SIDES AND THE END OF THE PENNINSULA.
FINAL COMPLETE BUILDING INSPECTION 09/18/2009 Disapproved - NO FEE JHINDMAN
Note: Inspection Resulted at 9/18/2009 2:45:11 PM CANNOT FINAL UNTIL ELECTIC HAS PASSED.
FRAMING 08/06/2009 APPROVED JHINDMAN
2ND ROUGH ELECTRICAL 08/05/2009 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
2ND ROUGH ELECTRICAL 08/03/2009 CANCELLED BY APPLICANT JMONTARULI
Note: The contractor called to cancel this inspection
2ND ROUGH ELECTRICAL 07/31/2009 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 7/31/2009 2:39:31 PM NM CABLE NEEDS TO BE 1.25IN FROM EDGE OF FRAMING MEMBER OR PROTECTED. OVER ON BOXFILL AT 2 GANG BOX IN HALLWAY. FIRE RATED FOAM IS NEEDED AT PENETRATIONS LEADING INTO ATTACK.

Review History

Department Status Date In Date Out
ELEC COMPLETE 10/12/2009 10/12/2009
Note: Released By: LHITES
ELEC HOLD 10/09/2009 10/09/2009
Note: Held By: JMCGOWEN ADD 2 OUTLETS TO KITCHEN REMODEL SEE YELLOW HIGHLIGHT Provide the required counter top outlet locations,
BLD COMPLETE 08/04/2009 08/04/2009
Note: Released By: FREODICA change interior wall from 42" to 10"0 tall Revision.
BLD COMPLETE 07/27/2009 07/27/2009
Note: Released By: JMCGOWEN correction- wall section & additional electricial
BLD HOLD 07/23/2009 07/23/2009
Note: Held By: LHITES 1. provide knee wall detail 2. provide general purpose outlets on knee wall. 3. confirm 2 appliance circuit gfci for kitchen outlets.
ZON COMPLETE 07/23/2009 07/23/2009
Note: Released By: BBARTON interior work only

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/12/2009
REINSPECTION FEE ¤40.00 10/12/2009
REVISION ¤40.00 10/12/2009
REVISION ¤40.00 10/12/2009
SITE PLAN 20 ¤20.00 07/28/2009
REMODEL/ADDITION/ACCES INSPECT ¤40.00 07/28/2009
BUILDING DISCOUNT 100% (¤150.48) 07/28/2009
ELECTRIC FEE ¤67.20 07/28/2009
PERMIT FEE ¤20.00 07/28/2009
PLAN CHECK FEE ¤40.00 07/28/2009
Fees Total Due: ¤0.00 Total Paid: ¤196.72