Permit #2009090670

Permit Details

Status: FINAL

Parcel Id: 07-11-31-1090-00000-00B0
Total Square Footage: 2595 sqft
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: 386-338-7785
Location Address: 160 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 10/09/2009
NOC: Unknown
Applicant name: THOMAS M SCAGLIONE
Owner: ASNACO LLC C/O INTERSTATE HOLDINGS INC

Address

1307 S INTERNATIONAL PKWY

LAKE MARY, FL 32746

Address

SUITE 2051

LAKE MARY, FL 32746

Contracted Stated Job Value: ¤1,000.00
Job Description: BLDG. B UNIT 206/207-- CONSTRUCT PARTITION WALLS
Type: CN

Contractor

T-CON GROUP, INC.
Status Location Address State License Number Phone
CANCEL

3246 NORTH POWERLINE ROAD

POMPANO BEACH, FL 33069

CBC1251999 (Exp: 08/31/2020) 954-825-8369

Sub Contractors

HAROLD C WINTZ
Status Location Address State License Number Phone
CANCEL

1721 Palm Road

Ormond Beach, FL 32174

EC13001342 (Exp: 08/31/2018) (386) 212-4786

Inspection History

Type Request Date Result Inspector
FIRE FINAL 03/08/2011 FINAL APPROVED LHITES
Note: THIS IS A REINSPECTION
COMMERCIAL BUILDING FINAL 03/04/2011 APPROVED RMARVEL
UTILITY COMMERCIAL FINAL 03/04/2011 APPROVED DSPENCER
UTILITY COMPANY FINAL 03/04/2011 APPROVED DSPENCER
FIRE FINAL 03/04/2011 CANCELLED BY APPLICANT LHITES
Note: Tom came in to cancel inspection.
COMMERCIAL POWER INSPECTION 02/11/2011 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
COMMERCIAL POWER INSPECTION 04/27/2010 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 4/27/2010 3:32:48 PM EMERGENCY LIGHT NEEDS TO BE INSTALLED OR BOX BLANKED FOR THIS INSPECTION SINCE THERE ARE NO LOCKS ARE INSTALLED ON PANELS.
2ND ROUGH ELECTRICAL 03/30/2010 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
COMMERCIAL POWER INSPECTION 03/26/2010 CANCELLED BY APPLICANT RMARVEL
2ND ROUGH ELECTRICAL 03/26/2010 CANCELLED BY APPLICANT RMARVEL
Note: THIS IS A REINSPECTION
FRAMING 03/24/2010 APPROVED CMINI
Note: THIS IS A REINSPECTION
2ND ROUGH ELECTRICAL 03/24/2010 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 3/24/2010 2:51:06 PM NEED TO REPLACE OVERBENT BROKEN M.C .... NEED NAIL PLATE WHERE M.C IS LESS THAN 1- 1/4" TO FRAMING MEMBER
FRAMING 01/27/2010 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 1/27/2010 2:11:03 PM PLAN SPECIFIES METAL STUD FRAMING WOOD FRAMING INSTALLED NEED REVISION....WALLS NOT ALL INSTALLED PER PLAN..
2ND ROUGH ELECTRICAL 01/27/2010 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 1/27/2010 3:24:46 PM ELECTRICAL IS NOT COMPLETE. DOES NOT MATCH PLANS.

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/23/2010 03/23/2010
Note: Released By: LHITES only adding 3 receptacles instead of 6 per print/crossed iff akk receptacles not being put in run 3 recep to 20amp breaker all ran in 12-2 m.c cable stapled and fire caulked wall circuit #30
FD1 COMPLETE 03/01/2010 03/01/2010
Note: Released By: JPATTEE
BLD COMPLETE 02/26/2010 03/01/2010
Note: Released By: JJOSEPH Revision Indicated emergency light locations and exit lights. Changed office to reception
BLD HOLD 02/09/2010 02/09/2010
Note: Held By: JMCGOWEN Revision change framing material from metal studs to wood framing, eliminated some partition walls and changed lat out in206(doors) provide revised locations of emergency lights and exit lights, the office that egresses through an other office is prohibited as per FBC 1014.2
FD1 HOLD 02/09/2010 02/10/2010
Note: Held By: JPATTEE Comments and revisions are confusing, what is the work to be done? Where?
FI1 COMPLETE 10/07/2009 10/08/2009
Note: Released By: JPATTEE
BLD COMPLETE 10/07/2009 10/07/2009
Note: Released By: JJOSEPH Correction REMOVE WATER HEATER OFF PLAN CHANGE DOOR SWING ADD SPRING HINGE DOOR CLOSURES TO B.R NOTE ON LEVEL DOORS ADD WATER COOLER
PLUM COMPLETE 10/07/2009 10/07/2009
Note: Released By: FREODICA
ELEC COMPLETE 10/02/2009 10/02/2009
Note: Released By: LHITES
PLUM HOLD 10/01/2009 10/01/2009
Note: Held By: FREODICA 1. Provide drinking fountain per FPC 2007 Table 403.1.
BLD HOLD 10/01/2009 10/01/2009
Note: Held By: JMCGOWEN panel squedules provide self closing door hardware for rest room door that swings in to corridor
BLD HOLD 09/30/2009 09/30/2009
Note: Held By: JJOSEPH 1.Revise the restroom doors as per section 1008.1.8 of the FBC 2007 to provide hardware.
ELEC HOLD 09/30/2009 09/30/2009
Note: Held By: LHITES 1.) Provide panel locations,schedule,and load calculations. 2.) Provide power and lighting circuits. 3.) Provide water heater size.. these units have existing insta-hot in bathrooms.
FI1 HOLD 09/30/2009 10/01/2009
Note: Held By: JPATTEE Does this unit have emergency lights? Change bathroom door swing on both. What is a sensor?
PLUM HOLD 09/30/2009 09/30/2009
Note: Held By: FREODICA 1. Plan shows water heaters in mechanical rooms. Clarify where those water heaters are intended to be used as the existing restrooms have instant heaters already installed.
ZON COMPLETE 09/30/2009 09/30/2009
Note: Released By: BBARTON interior office renevations only

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FIRE PLANS REVIEW ¤25.95 10/09/2009
PERMIT FEE ¤50.00 10/09/2009
PLAN CHECK FEE ¤100.00 10/09/2009
PLUMBING FEE ¤60.60 10/09/2009
RADON FEE ¤12.98 10/09/2009
ADMIN COMMERCIAL ¤60.00 10/09/2009
BUILDING CODE ADMIN FUND ¤12.98 10/09/2009
BUILDING DISCOUNT 100% (¤298.08) 10/09/2009
ELECTRIC FEE ¤60.60 10/09/2009
SITE PLAN 20 ¤20.00 10/09/2009
ADDITIONAL FEE ¤40.00
EXTENSION ¤40.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
REVISION ¤80.00
REVISION ¤40.00
Fees Total Due: ¤360.00 Total Paid: ¤105.03