I want to search for...

Permit #2009110191

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7009-00180-0360
CONDITIONED SPACE: 2235 sqft
GARAGE: 530 sqft
OPENED PORCH (WITH ROOF) : 439 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 3316 sqft
Block: 00180
Subdivision: 2208 - SECTION 9-FLORIDA PARK
Job Phone: (386)445-9393
Location Address: 3 FAIRCHILD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/27/2010
NOC: Unknown
Applicant name: ANTONIO AMARAL JR
Owner: NADA OF PALM COAST L.L.C.

Address

13 UTLITY DRIVE

PALM COAST, FL 32137

Lot: 0360
Contracted Stated Job Value: ¤149,900.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AMARAL CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32135

CBC058062 (Exp: 08/31/2020) (386)445-9393 (386)446-0403

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ET11000823 (Exp: 09/09/2016) (386) 437-0607 (386)437-1847
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
ANTONIO JR AMARAL
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2018) (386)445-9393 (386)446-0403
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955

Inspection History

Type Request Date Result Inspector
RESIDENTIAL EARLY POWER 10/22/2010 APPROVED CMINI
Note: Inspection Resulted at 10/22/2010 3:17:30 PM CALLED SUSAN FROM FPL AT 3:15 SIMMONS ELEC
PRE DRIVEWAY 09/02/2010 APPROVED BCHAMBERLAIN
Note: There was no swale plan in the box on site.
LATH /BRICK FLASHING 06/15/2010 APPROVED CMINI
INSULATION INSPECTION 04/28/2010 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 04/26/2010 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 4/26/2010 2:37:32 PM MISSING FIRESTOP AT PENETRATION OF DRYER VENT AND REAR PORCH WIRES THRU TOP PLATE TO ATTIC SPACE.
ALL ROUGH 04/20/2010 APPROVED DROCKWELL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/20/2010 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/14/2010 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 4/14/2010 3:05:46 PM NEED TO BLOCK OFFSET STRAPS ON TRUSSES CHECK ALL......SHIM UNDER TRUSS IN M.BA.RIGHT SIDE OF TUB.......STRAP AND ANCHOR OUTSIDE BATH WALLS.....MISSING STRAP FRONT PORCH JACK TRUSS....NEED REVISION FOR CHANGE OF TRUSS HOLD DOWN SCHEDULE.
LINTEL 03/18/2010 APPROVED CMINI
FOUNDATION SURVEY APPROVED BY STORMWATER 03/10/2010 APPROVED WKINELL
FOUNDATION SURVEY APPROVED BY ZONING 03/10/2010 APPROVED ECOYNE
MONOLITHIC SLAB INSPECTION/SLAB 03/05/2010 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 03/01/2010 APPROVED DROCKWELL
STORMWATER FINAL INSPECTION
Note: 11/19/09 lot has been cleared//no damage//jc
FINAL SURVEY
UTILITY COMPANY FINAL
FINAL COMPLETE BUILDING INSPECTION

Review History

Department Status Date In Date Out
BLD COMPLETE 04/19/2010 04/19/2010
Note: Released By: JMCGOWEN Revised truss hold down schedule to match trusses
ZON COMPLETE 01/19/2010 01/19/2010
Note: Released By: ECOYNE revised landscaping plan to include shrubs around corners of house around a/c unit new color sheet with codes and manufactures and tree survey.
SW1 COMPLETE 01/19/2010 01/19/2010
Note: Released By: LAPTEKAR revised landscaping plan to include shrubs around corner of house
BLD COMPLETE 01/19/2010 01/21/2010
Note: Released By: JJOSEPH revised detail shee D1 to current electrical code move slider from family room to nook area also changed mechanical subcontractors to RHS Mechanical
PLUM COMPLETE 11/16/2009 11/16/2009
MECH COMPLETE 11/16/2009 11/16/2009
SW1 COMPLETE 11/16/2009 11/17/2009
Note: Right of way application signed.
ELEC COMPLETE 11/10/2009 11/10/2009
BLD HOLD 11/09/2009 11/10/2009
Note: Held By: JJOSEPH 1.Provide tamper resistance recptacles for all 15 and 20A 120V per NEC 2008 section 406.11. 2. Indicate the current design code for note 2 located in sheet D.1.
SW1 HOLD 11/09/2009 11/12/2009
Note: 1. Right of way application needs signature. emailed 11/12/09
ZON HOLD 11/09/2009 11/10/2009
Note: Held By: ECOYNE provide landscaping around front corner of home provide landscape to place around a/c unit provide tree survey showing existing trees provide color of home sample or mfg name & number of paint. corrected color wheel 01/11/10 ecoyne 11:30am sent e-mail for color samples - could not find colors in color wheel paint samples 01/11/10 ecoyne 1:38ppm

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FIRE COMM IMPACT FEE 4/1/09 ¤190.48 01/27/2010
MECHANICAL FEE ¤210.60 01/27/2010
PERMIT FEE ¤20.00 01/27/2010
PARKS IMPACT FEE 4/1/09 ¤1,230.83 01/27/2010
PLAN CHECK FEE ¤100.40 01/27/2010
PLUMBING FEE ¤210.60 01/27/2010
RADON FEE ¤16.58 01/27/2010
BUILDING CODE ADMIN FUND ¤16.58 01/27/2010
BUILDING DISCOUNT 100% (¤1,128.78) 01/27/2010
ELECTRIC FEE ¤210.60 01/27/2010
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 01/27/2010
SITE PLAN 20 ¤20.00 01/27/2010
STORM WATER PERMIT FEES ¤80.00 01/27/2010
TRANS IMPACT FEE 7-RESIDENTIAL ¤3,565.34 01/27/2010
NEW RESIDENTIAL INSPECTIONS ¤502.00 01/27/2010
REVISION ¤40.00
EARLY POWER INSPECTION ¤40.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
Fees Total Due: ¤160.00 Total Paid: ¤8,845.23