I want to search for...

Permit #2009110254

Permit Details

Status: FINAL

Parcel Id: 16-11-30-0000-01010-0050
Block: 01010
Subdivision: -
Job Phone: (386)441-2299
Location Address: 35 HARGROVE GRADE
Type: SLR - SOLAR POOL
Issue Date: 12/09/2009
NOC: RECORDED
Applicant name: WILLIAM HENRY GALLAGHER
Owner: MATUSZCZAK MICHAEL E & CYNTHIA J

Address

15 CHICKASAW COURT

PALM COAST, FL 32137

Lot: 0050
Contracted Stated Job Value: ¤150,000.00
Job Description: SOLAR PHOTOVOLTAIC ELECTRIC PANELS ON ROOF
Type: CN

Contractor

SOLAR FIT
Status Location Address State License Number Phone Fax
ACTIVE

1523 RIDGEWOOD AVENUE

Ormond Beach, FL 32176

CVC56690 (Exp: 08/31/2026) (386)441-2299 (386)677-6349

Sub Contractors

JOHN RENTON
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1726

New Smyrna Beach, 32168

EC0002679 (Exp: 08/31/2014) (386)423-9314 (386)000-0000

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 12/21/2009 APPROVED JHINDMAN
Note: Inspection Requested at 12/18/2009 2:46:15 PM SOMEONE FROM OUR COMPANY WILL BE THERE AFTER 8:00
FINAL INSPECTION (MISC) 12/21/2009 FINAL APPROVED JHINDMAN
Note: Inspection Requested at 12/18/2009 2:47:50 PM SOMEONE FROM OUR COMPANY WILL BE THERE AFTER 8:00

Review History

Department Status Date In Date Out
ELEC COMPLETE 12/08/2009 12/08/2009
Note: Released By: JMCGOWEN additional drawing showing how panel are attached to struct
ELEC HOLD 12/03/2009 12/04/2009
Note: Held By: JMCGOWEN Correction sign and sealed plans print of bldg. provide print of location of breaker box manufacturers data of use cable provide fastening detail from roof to the pv panel , this design will need to be done by the site specific design professional.
ELEC HOLD 11/13/2009 11/13/2009
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110254 (Solar Photovoltaic Electric @ 35 Hargrove Grade) 11/13/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide signed and sealed engineer's letter affirming truss system will sustain additional weight load of PV panels. 2. Provide manufacturer's data on XLP USE "MC" cable to be used on exterior of building. Please review 2008 NEC 338.12(B) for uses not permitted for type USE. 3. Identify which building will have this system installed on it. 4. Identify the panel or panels that the circuit breakers will be installed in. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
ELEC HOLD 11/12/2009 11/13/2009
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110254 (Solar Photovoltaic Electric System @ 35 Hargrove Grade) 11/13/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide quantity of PV stringers for determination of size of circuit and disconnecting means. 2. Clarify type of cable looping between PV modules and from PV modules to Wet Location Box. Riser diagram states USE-2 "MC" cable. Please review NEC 330 and 338 regarding uses of these materials. 3. Provide plan location of "Wet Location Box", inverters, disconnects which are shown on Riser Diagram. 4. Plans show a total of 96 - 244W PV modules on roof of building, but Riser diagram shows only 1 - 5000W inverter with 1 - 30A circuit breaker. Please clarify how the 23,424W potential from the PV panels is combined before entering the service panel, and revise the panel circuit breaker to protect the load. Revise Riser diagram as required. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
ZON COMPLETE 11/12/2009 11/12/2009
Note: Released By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN COMMERCIAL ¤60.00 12/09/2009
BUILDING DISCOUNT 100% (¤1,021.50) 12/09/2009
PERMIT FEE ¤1,050.00 12/09/2009
PLAN REVIEW 25 ¤25.00 12/09/2009
SITE PLAN 10 ¤10.00 12/09/2009
Fees Total Due: ¤0.00 Total Paid: ¤123.50