Permit #2009110452
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-1090-00000-00B0 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: 386-338-7785 |
| Location Address: 160 CYPRESS POINT PKWY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 02/18/2010 |
| NOC: Unknown |
| Applicant name: THOMAS M SCAGLIONE |
| Owner: ASNACO LLC C/O INTERSTATE HOLDINGS INC |
|
Address 1307 S INTERNATIONAL PKWY LAKE MARY, FL 32746 |
|
Address SUITE 2051 LAKE MARY, FL 32746 |
| Contracted Stated Job Value: ¤1,122.00 |
| Job Description: BLDG C UNIT 110 - ELECTRICAL/MECH FOR REFRIG. DISPLAY CASES SEAFOOD MARKET |
| Type: CN |
Contractor
T-CON GROUP, INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
3246 NORTH POWERLINE ROAD POMPANO BEACH, FL 33069 |
CBC1251999 (Exp: 08/31/2020) | 954-825-8369 |
Sub Contractors
MICHAEL ALLEN PHILLIPS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 478 BUNNELL, FL 32110 |
CAC1814966 (Exp: 08/31/2014) | 386-262-6034 | 866-369-7390 |
JOHN EDWARD GAMBONE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
55 BARRISTER LN PALM COAST, FL 32137 |
ER13013466 (Exp: 08/31/2014) | 386-586-9144 | (386)246-6305 |
Inspection History
| Type | Request Date | Result | Inspector |
| UTILITY COMMERCIAL FINAL | 11/18/2010 | Disapproved - NO FEE | DSPENCER |
| Note: Inspection Resulted at 11/18/2010 3:50:03 PM PLEASE CALL PAT GARRETT OR DANNY SPENCER TO MEET ON SITE # 386-931-2560 OR #386-569-9082 TO ARRANGE MEETING AND RESCHEDULE INSPECTION | |||
| UTILITY COMPANY FINAL | 11/18/2010 | APPROVED | DSPENCER |
| FIRE FINAL | 11/18/2010 | Disapproved -FEE REQUIRED | LHITES |
| Note: Inspection Resulted at 11/18/2010 12:24:53 PM 1. NONE OF THE EMERGENCY LIGHTS ARE WORKING. 2. MUST HAVE FIRE EXTINGUISHERS IN PLACE FOR FINAL INSPECTION | |||
| ELECTRICAL FINAL | 11/17/2010 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 11/10/2010 | CANCELLED BY APPLICANT | CMINI |
| 2ND ROUGH ELECTRICAL | 11/09/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ABOVE CEILING | 11/09/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| 2ND ROUGH ELECTRICAL | 10/22/2010 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: PER REQUEST FROM TOM Inspection Resulted at 10/22/2010 3:30:30 PM BURIAL DEPTH ON CONDUIT TO CONDENSORS FOR COOLERS NEED TO BE 18IN. 2 LOCATIONS OF RECEPTACLES DO NOT MATCH REVISED PLANS WHERE QUAD RECEPTACLES AIN PLACE OVER DUPLEX. NEED K.O. PLUG ON CONDENSORS WHERE THERE ARE UNSED OPENINGS. THIS INCLUDES SUB PANEL. | |||
| ABOVE CEILING | 10/22/2010 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: PER REQUEST FROM TOM Inspection Resulted at 10/22/2010 3:30:29 PM RECHECK STRAPPING IN MULTIPLE LOCATIONS. | |||
| ELECTRIC FEEDER | 10/22/2010 | APPROVED | RMARVEL |
| Note: REQUEST FROM TOM | |||
| PATIO | 08/11/2010 | APPROVED - AS NOTED | CMINI |
| Note: FOR AC COMPRESSORS PER LARRY HITES Inspection Resulted at 8/11/2010 3:30:59 PM PATIO SLAB FOR A/C | |||
| COMMERCIAL POWER INSPECTION | 07/23/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL POWER INSPECTION | 07/13/2010 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Wintz came in to schedule this inspection Inspection Resulted at 7/13/2010 10:37:17 AM OPEN BOX ABOVE REAR DOOR. SWITCH HANGING OUT OF WALL WITH BOX PARTIALLY COVERED BY ADJOINING WALL. NEED PLANS FOR INSPECTION. | |||
| FRAMING | 04/29/2010 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 04/23/2010 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/23/2010 1:24:03 PM NEED TO HAVE FRAMING PLAN ON JOB FOR INSPECTION | |||
| FRAMING | 04/20/2010 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: requested by contractor Inspection Resulted at 4/20/2010 2:58:16 PM PLANS CALL FOR WOOD FRAME WALLS. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 04/08/2010 | APPROVED | CMINI |
| COMMERCIAL BUILDING FINAL | |||
| UTILITY COMMERCIAL FINAL | |||
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | |||
| Note: THIS IS A REINSPECTION |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 11/15/2010 | 11/15/2010 |
| Note: Released By: JMCGOWEN Revised panel schedule change electrical contractor | |||
| BLD | COMPLETE | 10/14/2010 | 10/14/2010 |
| Note: Released By: JJOSEPH | |||
| BLD | HOLD | 10/12/2010 | 10/12/2010 |
| Note: Held By: JJOSEPH Seafood counter needs to be accessible. Faxed and Emailed on 10/12/10 at 9:30AM | |||
| ELEC | COMPLETE | 09/24/2010 | 09/24/2010 |
| Note: Released By: LHITES revision- changed the location of equipment | |||
| BLD | HOLD | 07/29/2010 | 07/29/2010 |
| Note: Held By: FREODICA 1. Provide thickness and elevation above grade of slab for compressors. | |||
| BLD | COMPLETE | 07/29/2010 | 07/29/2010 |
| Note: Released By: FREODICA Revision: Added 14' L x4' W x 4" thick concrete slab for compressors. | |||
| PLLA | COMPLETE | 07/27/2010 | 07/27/2010 |
| Note: Released By: WBUTLER | |||
| ZON | COMPLETE | 07/23/2010 | 07/23/2010 |
| Note: Released By: ECOYNE | |||
| ENGIN1 | COMPLETE | 07/23/2010 | 07/27/2010 |
| Note: Released By: AWEBB | |||
| BLD | COMPLETE | 04/26/2010 | 04/26/2010 |
| Note: Released By: JMCGOWEN change 2x4 wood frame to metal studs non structural | |||
| ELEC | COMPLETE | 02/18/2010 | 02/18/2010 |
| Note: Released By: SKNOPF | |||
| ZON | COMPLETE | 02/18/2010 | 02/18/2010 |
| Note: Released By: ECOYNE | |||
| FI1 | CANCEL | 02/18/2010 | 02/18/2010 |
| Note: no review required - per Jeff P. | |||
| UD1 | COMPLETE | 02/18/2010 | 02/18/2010 |
| Note: Released By: CJOHNSON Plumbing was submitted under a different permit | |||
| MECH | COMPLETE | 02/17/2010 | 02/17/2010 |
| Note: Released By: FREODICA Correction on hold comment for exhaust hood 1. Exhaust hood is not required as electric stove and fryer were removed | |||
| BLD | COMPLETE | 02/17/2010 | 02/18/2010 |
| Note: Released By: JJOSEPH Correction plans deletion of hood,stove,fryer clarify mop sink on inner & outer wall of new extended closet. | |||
| MECH | HOLD | 02/12/2010 | 02/12/2010 |
| Note: Held By: FREODICA Correction comment: 1. Provide separate permit for exhaust hood. Hood shall be type 1. | |||
| BLD | HOLD | 02/12/2010 | 02/12/2010 |
| Note: Held By: JJOSEPH 1.Revise the drawing to make separation between the Food preparation area and the rest of Store. 2. Please make a revision on the bathroom area, it cannot open into the Food preparation area. 3.Need to provide occupancy classification (use of space) and occupant load . | |||
| ELEC | HOLD | 02/11/2010 | 02/12/2010 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452 (Fish Store/Restaurant @ Unit C110 160 Cypress Point Pkwy.) 2/12/2010 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Identify circuits for commercial electric stove, fryer, exhaust hood and make-up air. 2. Provide entirely revised load calculations. 3. A separate permit must be pulled for the hood. 4. Provide disconnects for AHU and Water Heater. 5. Coordinate amperage of all equipment between power plan and panel schedule loads. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| ELEC | COMPLETE | 01/26/2010 | 01/26/2010 |
| Note: Released By: SKNOPF Revised load calcs (per engineer) Approved for Release. | |||
| BLD | HOLD | 01/26/2010 | 02/12/2010 |
| Note: Held By: JJOSEPH Correction exted partition closet for mop sink & water heater business & occupancy classification exhaust hood detail enclosed. | |||
| BLD | HOLD | 01/26/2010 | 01/26/2010 |
| Note: Held By: JJOSEPH Need to provide occupancy classification (use of space) and occupant load before releasing the permit application | |||
| ELEC | HOLD | 01/15/2010 | 01/15/2010 |
| Note: Held By: SKNOPF correction - new calcs CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452 (Tenant Upfit for Unit C-110 @ 160 Cypress Point Pkwy.) 1/15/2010 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide Load Calculations. 2. Verify AHU and CU loads. 3. Verify use of circuit C110-10. 4. Clarify circuit numbers for ACU's. 5. Clarify use of circuit #20. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| PLUM | CANCEL | 01/14/2010 | 01/14/2010 |
| Note: Plumbing was applied under separate Permit Application No. 2010010285. | |||
| ELEC | HOLD | 01/05/2010 | 01/05/2010 |
| Note: Held By: SKNOPF changed lt's circuit to new panel schedule corrected load calcs changed service to 225 CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452 (Tenant Upfit Suite C110 @ 160 Cypress Point Pkwy.) 1/5/2010 The following items must be resolved in order to complete the Building Permit plan review. Previous Electrical Comments from 12/30/2009: 1. Complete. 2. Previous Item #2: Provide a revised Demand Load Calculation per FBC 106.3.5 Electrical #7 and NEC 220 Part III showing the actual existing loads plus all of the new loads. Total shown for new equipment loads is incorrect. Revise. 3. Previous Item #3: Provide a revised partial Electrical Riser Diagram, as required dependent on resulting Demand Load Calculation Item #2 above, showing the tenant feeder conductor size, feeder OCP, and panel. #3/0 THWN is only good for 200A. Revise feeder size and identify correct conduit size for new feeder. 4. Complete. Previous Electrical Comments from 1-4-2010: 1. Complete. 2. Complete. 3. Coordinate the loads shown in the load calculation totals on the plan sheet with the loads shown for the same new equipment in the panel schedule for the following: a. Ice Machine - Load calc. shows 6.8A (.8KVA) vs. Panel Sched. shows .5KVA b. Meat Case - Load calc. shows 8.9A (1.1KVA) vs. Panel Sched. shows .8KVA c. Seafood Salad - Load calc. shows 4.1A (.5KVA) vs. Panel Sched. shows .8 KVA d. Standup Freezer - Load calc. shows 5.3A (.6KVA) vs. Panel Sched. shows .8KVA e. Meat Grinder - Load calc. shows 8.2A (1.0KVA) vs. Panel Sched. shows .6KVA f. Walk-in Cooler - Load calc. shows 5.2A (.6KVA) vs. Panel Sched. shows .8KVA g. Meat Cutter - Load calc. shows 7A (1.5KVA) vs. Panel Sched. shows 5KVA h. Hot Water Heater - Load calc. shows 26A (5.4KVA) vs. Panel Sched. shows 3.5KVA i. 125A Sub-panel - Load calc. shows 38.6A (8.0KVA) vs Panel Sched. 7.8KVA 4. Complete. New Electrical Comments: 1. Circuit # 20 is shown on both existing power plan for 6 receptacles and on new equipment power plan for Walk-in Cooler. Coordinate circuits. 2. New Equipment demand load total shown is incorrect per information and values given on equipment location plan. Revise new equipment demand total. 3. Demand Load calculation given shows 222.5A, but feeder is still shown as #3/0 THHN with a 200A circuit breaker OCP. #3/0 THHN is only good up to 200A. Revise feeder and OCP to accommodate demand load and provide size and type of conduit for revised feeder. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | COMPLETE | 01/04/2010 | 01/04/2010 |
| Note: Released By: FREODICA Note: If walk-in cooler is packaged type (plug- in electrical), mechanical review is not required but if condenser is a remote from cooler, mechanical revision is required. | |||
| PLUM | HOLD | 01/04/2010 | 01/05/2010 |
| Note: Held By: FREODICA NEW PLUMBING RISER WITH EXISTING SEWER & SINK ADDITION NO MECHANICAL CHANGES Review Comments for submitted corrections Based on previous review comments dated 12/23/09 the ff. items need to be addressed: Item 1 : Sanitary layout & riser diagram - Sanitay layout does not show the building backgound and location of plumbing fixtures. Riser diagram does not show where the new sanitary lines and vent system are tied in to the existing. Item 2: Dometic water layout & riser - Need to be addressed. Item 3: Material specifications of DWV & domestic water - Need to be addressed. Item 5: Plumbing fixture specifications- need to be addressed. Item 6: Provide drinking fountain - need to be addressed. | |||
| ELEC | HOLD | 12/31/2009 | 01/04/2010 |
| Note: Held By: SKNOPF ELECTRIC REVISION/NO MECHANICAL CHANGES /NEW PLUMBING RISER WITH EXIST SEWER & SINK ADDITION CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452 (Tenant Upfit Suite C110 @ 160 Cypress Point Pkwy.) 1/4/2010 The following items must be resolved in order to complete the Building Permit plan review. Previous Electrical Comments from 12/30/2010: 1. Previous Item #3: Circuit #8 is shown on both lighting and power plans. Revise load in panel and coordinate circuit identification. 2. Previous Item #4: Provide a revised Demand Load Calculation per FBC 106.3.5 Electrical #7 and NEC 220 Part III showing the actual existing loads plus all of the new loads. New given equipment loads plus actual existing loads appear to be greater than 200A service change shown. 3. Previous Item #5: Provide a revised partial Electrical Riser Diagram, as required dependent on resulting Demand Load Calculation Item #2 above, showing the tenant feeder conductor size, feeder OCP, and panel. 4. Previous Item #11: Shell building plans show that an Insta-Hot was installed in this tenant space for the bathroom sink, but this equipment is not listed in the submitted panel schedule. Provide circuit identification, circuit breaker size, and load for this equipment if it is to remain. If it is to be deleted, and replaced with hot water piping from the new Hot Water Heater, show on plans that the Insta-Hot is to be deleted on plans and panel schedule. New Electrical Comments: 1. The circuits identified in the panel schedule do not match the circuits on the layout plan for the following: a. 1, 2, 3, 4, 5, 6, 7, 8, 9, 11:13, 12:14, 16:18, 15:17, 26 and 28. Coordinated between panel schedule and plans submitted. 2. The revised Demand Load Calculation is missing the following information: a. Revised existing load should include the 2-pole Condensing Unit loads. b. New equipment total load. c. All continuous loads are to be included at 125% (includes wire size, circuit breaker and load calc.) 3. Coordinate the loads shown in the load calculation totals on the plan sheet with the loads shown for the same new equipment in the panel schedule for the following: a. Ice Machine - Load calc. shows 6.8A (.8KVA) vs. Panel Sched. shows .5KVA b. Meat Case - Load calc. shows 8.9A (1.1KVA) vs. Panel Sched. shows .8KVA c. Seafood Salad - Load calc. shows 4.1A (.5KVA) vs. Panel Sched. shows .8 KVA d. Standup Freezer - Load calc. shows 5.3A (.6KVA) vs. Panel Sched. shows .8KVA e. Meat Grinder - Load calc. shows 8.2A (1.0KVA) vs. Panel Sched. shows .6KVA f. Walk-in Cooler - Load calc. shows 5.2A (.6KVA) vs. Panel Sched. shows .8KVA g. Meat Cutter - Load calc. shows 7A (1.5KVA) vs. Panel Sched. shows 5KVA h. Hot Water Heater - Load calc. shows 26A (5.4KVA) vs. Panel Sched. shows 3.5KVA i. 125A Sub-panel - Load calc. shows 38.6A (8.0KVA) vs Panel Sched. 7.8KVA 4. Ground wire for feeder from Meter to 225A panel does not match from plan to riser. Coordinate. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| ELEC | HOLD | 12/30/2009 | 12/30/2009 |
| Note: Held By: SKNOPF ELECTRICAL PLAN REVIEW CORRECTIONS/CORRECTION CAME IN ON 12/28/2009 NOT ABLE TO REVIEW WAITING ON UTLITIES TO SEND ORIGINAL FOLDER BACK TO BD. CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452 (Commercial Interior Alteration @ Unit C-110, 160 Cypress Point Pkwy.) 12/30/2009 The following items must be resolved in order to complete the Building Permit plan review. Previous Electrical Comments from 12-22-2009: 1. Complete. 2. Complete. 3. Circuit #8 is shown on both lighting plan and power plan (bath area). Revise panel load. 4. Provide a revised Demand Load Calculation per FBC 106.3.5 Electrical #7 and NEC 220 Part III showing the actual existing loads. New given equipment loads plus actual existing loads appear to be greater than 200A. 5. Provide a revised partial Electrical Riser Diagram, as required dependent on resulting Demand Load Calculation Item #4 above, showing the tenant feeder conductor size, feeder OCP, and panel. 6. Provide manufacturer's submittal documents for all commercial kitchen equipment. 7. Panel schedule shows the AHU as 2P with 2 different sizes for the circuit breaker. Identify correct circuit breaker sizes. There are 2 AHU and 2 ACU in this space. Revise panel schedule to accurately reflect required circuit breaker sizes and loads for these 4 units per nameplates. 8. Same as #7. 9. Complete. 10. Panel schedule identifies circuit #36 as "fish counter", but this equipment is not identified on drawings. Provide location and type of device for this circuit. 11. Shell building plans show that an Insta-Hot was installed in this tenant space for the bathroom sink, but this equipment is not listed in the submitted panel schedule. Provide circuit identification, circuit breaker size, and load for this equipment. 12. Deleted. 13. Walk-In Cooler is shown as a 1P 20A circuit breaker with a 200VA load in the panel schedule. Update panel schedule with nameplate load. 14. Provide location on plan sheet for circuit #41 Wrapper equipment. 15. Complete. 16. Complete. 17. Revise loads in panel schedule for circuits 25 and 27 to reflect actual quantity of receptacles on each circuit per NEC 220.14(I). 18. Deleted. 19. Complete. New Electrical Comments resulting from latest submitted documents: 1. None of the new circuits submitted for the new equipment match the circuits shown on the panel schedule. 2. Latest load calculation submitted does not include new "Fish counter" or "Wrapper" equipment. 3. Remove "Electric Stove" from panel schedule as it appears to have been deleted. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| MECH | HOLD | 12/23/2009 | 12/23/2009 |
| Note: Held By: FREODICA 1. Provide HVAC plans and details suitable for review, construction and inspection. 2. Provide information on the use of building space. Plan shows electric stove. Is the space used as a restaurant? 3. Provide exhaust hood for the electric stove. Provide information on its type, duct layout, size, fan specifications & make- up air system. | |||
| PLUM | HOLD | 12/23/2009 | 12/23/2009 |
| Note: Held By: FREODICA 1. Provide sanitary layout and riser diagram suitable for review, construction and inspection. 2. Provide domestic water layout and riser diagram. 3. Provide material specifications for sanitary (DWV) and domestic water. 4. Provide occupancy classification and occupant load. 5. Provide plumbing fixture specifications. 6. Provide drinking fountain. | |||
| UD1 | HOLD | 12/23/2009 | 12/29/2009 |
| Note: Held By: CJOHNSON 1. Provide legible water & sanitary layout for review. 2. I understand an exemption was approved for the grease interceptor. Provide grease interceptor exemption letter. Label the under the sink grease trap with size on the plans. Provide spec sheet for the device | |||
| ELEC | HOLD | 12/22/2009 | 12/22/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452 (Commercial Interior Alteration @ Unit C-110, 160 Cypress Point Pkwy.) 12/22/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide full size plans/details suitable for review, construction and inspection. Plans must be large enough for electronic scanning and filing, minimum 11" x 17". 2. Identify all circuits, both new and existing, on plan sheet for all lighting, devices, and equipment. Identify whether new equipment is to be plug-and-cord to a receptacle and show receptacle location, or hard-wired. 3. Circuit #8 is shown on both lighting plan and power plan (bath area). Revise panel load. 4. Provide a Demand Load Calculation per FBC 106.3.5 Electrical #7 and NEC 220 Part III. 5. Provide a partial Electrical Riser Diagram showing the tenant feeder conductor size, feeder OCP, and panel. 6. Provide manufacturer's submittal documents for all commercial kitchen equipment. 7. Panel schedule shows the AHU as 2P with 2 different sizes for the circuit breaker. Identify correct circuit breaker size. 8. Circuit breaker sizes on submitted panel schedule do not match loads for existing AHU and ACU. Identify correct circuit breaker size required per each unit nameplate. 9. Plan shows meat cutter is 30A, but panel schedule shows circuit breaker is 2P 20A. Identify correct circuit breaker size and equipment load per nameplate rating. 10. Panel schedule identifies circuit #36 as "fish counter", but this equipment is not identified on drawings. Provide location and type of device for this circuit. 11. Shell building plans show that an Insta-Hot was installed in this tenant space for the bathroom sink, but this equipment is not listed in the submitted panel schedule. Provide circuit identification, circuit breaker size, and load for this equipment. 12. Revise commercial stove load in panel schedule to be distributed across 2 phases. 13. Walk-In Cooler is shown as a 1P 20A circuit breaker with a 200VA load. Submit manufacturer electrical data, or photocopy of nameplate electrical data. 14. Provide location on plan sheet for circuit #41 Wrapper equipment. 15. Shell building plans show that tenant service panel, OCP, and feeder are 150A, but plans submitted show a 200A panel. Please clarify. 16. Provide manufacturer submittal electrical data for "125A Compressor sub-panel" listed as circuits 19, 21 in the panel schedule and show location of sub-panel and equipment. Provide sub-panel loads in main tenant panel. Include any sub-panels on Electrical Riser diagram with feeder sizes and OCP shown. 17. Revise loads in panel schedule for circuits 25 and 27 to reflect actual quantity of receptacles on each circuit per NEC 220.14(I). 18. Provide hood and make-up air circuits, circuit breaker sizes, and loads per FBC Mechanical sections 506 and 507, and NEC 220.14(A) and NEC 422 Appliances. 19. Provide method of installation for electrical branch circuits to free-standing equipment (meat case, standing freezer, seafood salad display). Identify type of conduit to these units. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| FI1 | HOLD | 12/01/2009 | 12/02/2009 |
| Note: Held By: JPATTEE Provide detailed floor plan indicating location of equipment | |||
| BLD | HOLD | 11/30/2009 | 12/01/2009 |
| Note: Held By: JJOSEPH Provide occupancy classification (use of space) and occupant load. | |||
| ELEC | HOLD | 11/23/2009 | 11/23/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009110452(Restaurant @ 160 Cypress Point Pkwy.) 11/23/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide Revised Demand Load Calculation per FBC 106.3.5 Electrical #7 and NEC 220 Part III. 2. Electrical Power Plan submitted is not for this building or address. Provide detail/plan suitable for review, construction and inspection. 3. Provide manufacturer's submittal documents for all commercial kitchen equipment. 4. Circuit breaker sizes shown on revised panel schedule do not match loads for existing AHU and ACU. 5. Existing loads do not match revised panel schedule circuits 25 and 27. 6. Circuit 22 is an existing circuit for an outside sign, but revised panel schedule shows this circuit for a 2P Meat Cutter. 7. Circuit 8 is shown on existing plans as both lighting and bath GFCI. Revise panel loads. 8. A separate permit will be required for the ansul system. 9. Identify plumbing and architectural changes and plumbing contractor. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| ZON | HOLD | 11/23/2009 | 11/24/2009 |
| Note: Held By: ECOYNE provide use of unit e-mail 11/23/09 8:36am |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 07/08/2010 |
| REINSPECTION FEE | ¤40.00 | 07/08/2010 |
| REINSPECTION FEE | ¤40.00 | 07/08/2010 |
| REVISION | ¤40.00 | 07/08/2010 |
| BUILDING DISCOUNT 100% | (¤352.81) | 02/18/2010 |
| ELECTRIC FEE | ¤60.67 | 02/18/2010 |
| FIRE PLANS REVIEW | ¤25.00 | 02/18/2010 |
| MECHANICAL FEE | ¤60.67 | 02/18/2010 |
| PERMIT FEE | ¤50.00 | 02/18/2010 |
| PLAN CHECK FEE | ¤100.00 | 02/18/2010 |
| PLUMBING FEE | ¤60.67 | 02/18/2010 |
| REVISION | ¤200.00 | 02/18/2010 |
| REVISION | ¤40.00 | 02/18/2010 |
| REVISION | ¤40.00 | 02/18/2010 |
| REVISION | ¤40.00 | 02/18/2010 |
| REVISION | ¤40.00 | 02/18/2010 |
| SITE PLAN 20 | ¤20.00 | 02/18/2010 |
| ADMIN COMMERCIAL | ¤60.00 | 02/18/2010 |
| CONTRACTOR CHANGE | ¤40.00 | 02/18/2010 |
| ADDITIONAL FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REVISION | ¤40.00 | |
| REVISION | ¤40.00 | |
| REVISION | ¤40.00 | |
| REVISION | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤360.00 | Total Paid: ¤644.20 |